Cool compressed air output

Option symbol

There is no heating of cooled, dehumidified air as it leaves the air dryer. 
The air flow capacity with this option is smaller than that of the standard 
dryer. (The external dimensions are identical to the standard product.)
Note) Perform thermal insulation treatment to the piping and equipment 

installed after the dryer to prevent the formation of condensation.

Conditions: Inlet air pressure: 0.7 MPa, Inlet air temperature: 35

°

C , 

Outlet air temperature: 10

°

C   Ambient temperature: 25

°

C

Anti-corrosive treatment

Option symbol

This minimises the corrosion of the copper and copper alloy parts when 
the air dryer is used in an atmosphere containing hydrogen sulfide or sul-
furous acid gas. (Corrosion cannot be completely prevented.)
Special epoxy coating: Copper tube and copper alloy parts. 
The coating is not applied on the heat exchanger or around electrical 
parts, as operation may be affected by the coating.

 Corrosion is not covered under warranty. 

C

A

IDFA3E to 11E

IDFA all models

For 1.6 MPa applications
Auto drain bowl type: 
Metal bowl with level gauge

Option symbol

The auto drain is changed from the standard one to one with a medium 
pressure specification. 
A metal bowl with a level gauge which can confirm the water level is used 
for the auto drain.

Specifications

1. Maximum operating pressure: 1.6 MPa 
2. Dimensions ··· same as standard products

K

IDFA6E to 37E

With heavy duty auto drain
(Applicable to 1.6 MPa)

Option symbol

The float type auto drain used in the 
standard air dryer is replaced with a 
heavy duty auto drain (ADH4000-04) 
which enables the drainage to dischar-
ge more efficiently. 

L

IDFA4E to 75E

Note 1) The heavy duty auto drain and the ball valve are both enclosed in the same 

shipping package as the main body of the air dryer. Customers are required 
to mount the parts to the air dryer. (Except IDFA22E to 75E)

Note 2) Customers will need to supply the fitting and tubing for the drain piping. 

(Except IDFA22E to 75E)

IDFA4E to 15E

IDFA22E to 75E

Drain outlet

(A)

(207)

(157)

Ball valve

Rc 1/2

Heavy duty 
auto drain

Air flow capacity m

3

/h (ANR)

Model

IDFA3E

18

IDFA4E

23

IDFA6E 

29

IDFA8E

32

IDFA11E

39

Ball valve

(O.D. ø10)

Drain tube:
Length approx.
0.95 m

Heavy duty 
auto drain

A

Model

  55

  67

139

  47

IDFA4E
IDFA6E
IDFA8E, 11E
IDFA15E

A

(mm)

Air Flow Capacity

Dimensions

Model

Approx. 100

Approx. 50

IDFA22E, 37E
IDFA55E, 75E

A

(mm)

Dimensions

Replacement Parts

Housing

(You don’t need
to purchase a 
new housing.)

Replacement Parts: Heavy Duty Auto Drain

Model

ADH-E400

(Replacement kit for

exhaust mechanism)

IDFA4E to 75E

Configuration

Replacement parts no.
(Description)

Replacement 
kit for exhaust 
mechanism

Model

IDFA6E to 15E

Auto drain
assembly part no.

Note

The AD48-8-X2110 auto drain, 
insulator, and one-touch fitting 
are included.

IDF-S0086

AD48-8-X2110

IDFA22E, 37E

Single auto drain unit

Series 

IDFA

E

Options 1

For “How to Order” optional 
models, refer to page 3 and 6.

9

Summary of Contents for IDFA E Series

Page 1: ...10 C R134a HFC R407C HFC Refrigerant 35 C 0 7 MPa Rated inlet condition Rc 3 8 Rc 1 2 Rc 3 4 Rc 1 R 1 R 11 2 R 2 Port size Power supply voltage Single phase 230 VAC 50 Hz Series IDFA E R134a HFC R407...

Page 2: ...C IDFA6E to 37E IDFA E 23 K IDFA4E to 75E IDFA E 23 L IDFA4E to 75E IDFA E 23 R IDFA4E to 75E IDFA E 23 T IDFA4E to 75E IDFA E 23 V 4 Data Condensed Water Calculation Dew Point Conversion Chart P 12 5...

Page 3: ...Selection Example Read the correction factor Obtain the correction factor A to D suitable for your operating condition using the table below The corrected air flow capacity which considers the user s...

Page 4: ...g combination cannot be achieved Combination of K L and V cannot be achieved because an auto drain can only be attached to a single option Note 3 Refer to page 9 for further details on optional specif...

Page 5: ...n outlet Compressed air inlet Compressed air outlet Evaporation thermometer Re heater Volume control valve Cooler Fan motor Condenser IDFA4E IDFA6E IDFA8E IDFA11E IDFA15E Drain outlet Evaporation ther...

Page 6: ...7 31 41 125 42 54 304 283 355 396 33 80 87 36 15 154 240 284 21 80 101 330 275 300 380 314 15 13 15 16 B C D E F G K L M N P Q 4 x 13 A C N M L P K F G D Inlet Outlet E B Q IDFA4E to 11E 4 x 13 A C N...

Page 7: ...ever the following combination cannot be achieved Combination of K L and V cannot be achieved because an auto drain can only be attached to a single option Note 3 Refer to page 9 for further details o...

Page 8: ...to obtain the dried air which goes through to the outlet side Pressure switch Compressed air inlet Compressed air outlet Auto drain Drain outlet Accumulator IDFA22E 37E 55E only Condenser Capillary tu...

Page 9: ...0 775 855 623 134 405 698 93 13 25 85 600 680 340 B C D E F G K L M N P Q Dimensions Model IDFA55E IDFA75E Port size mm R 2 A 470 855 800 900 128 273 868 968 110 13 500 75 700 526 110 B C D E F G K L...

Page 10: ...sions same as standard products K IDFA6E to 37E With heavy duty auto drain Applicable to 1 6 MPa Option symbol The float type auto drain used in the standard air dryer is replaced with a heavy duty au...

Page 11: ...This saves additional electrical wiring at the time of installation IDFA4E to 15E IDFA22E to 75E IDFA4E 6E 8E 11E IDFA15E Model 32 43 230 258 97 102 34 82 15 E D C B A Model Voltage 30 mA 230 V type B...

Page 12: ...F AB500 Applicable dryer Nominal thread size Material M10 Stainless steel 4 Pcs of 1 set mm IDFA4E to 75E Dimensions mm Mounting hole diameter 10 5 Optional Accessories Features Applicable dryer IDFA3...

Page 13: ...Port size D E B A C Compressed air outlet Compressed air inlet Port size D E mm mm Dimensions Dimensions Bypass piping set IDFA22E 37E IDFA55E 75E D B A C Compressed air outlet Port size Compressed ai...

Page 14: ...he amount of water which is included in the compressed air 1 m3 at 0 7 MPa pressure dew point of 25 C The amount of water is 3 0 g m3 10 Therefore the amount of condensed water is as following per 1 m...

Page 15: ...e the air dryer with an ambient temperature lower than 40 C Avoid installation on machines for transporting such as trucks ships etc Installation Caution The air exhaust should not flow into the neigh...

Page 16: ...ilation area once a month using a vacuum cleaner or an air blow nozzle Cleaning of Ventilation Area Caution Allow at least three minutes before restarting the dryer If the air dryer is restarted withi...

Page 17: ...the product is to be used in any of the following conditions 1 Conditions and environments outside of the given specifications or use outdoors or in a place exposed to direct sunlight 2 Installation o...

Reviews: