background image

TRT-BA-B5E-TC2017-60-004-EN

B 5 E

EN

OPERATING MANUAL

HUMIDIFIER

Summary of Contents for B 5 E

Page 1: ...TRT BA B5E TC2017 60 004 EN B 5 E EN OPERATING MANUAL HUMIDIFIER ...

Page 2: ...e manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental...

Page 3: ...mpty the water tank before transport and storage Do not drink the water Health hazard Note that high humidity levels may enhance the growth of biological organisms in the environment Make sure that objects in the surroundings of the device do not become wet or damp If moisture is present the output must be reduced If the output cannot be reduced the device must only be operated in intervals Absorb...

Page 4: ...nd does not belong in the hands of children Warning Risk of suffocation Do not leave the packaging lying around Children may use it as a dangerous toy Caution If the device is knocked over water will leak from the lower part Disconnect the device from the mains to prevent damage to the device caused by dry running Note Do not operate the device without an air filter inserted into the air inlet Wit...

Page 5: ... the water tank Do not use the power cable to drag the device Check whether the upper part is correctly positioned on the lower part Lift the device at the lower part After transporting the device observe the following Set up the device in an upright position after transport Storage Before storing the device observe the following Hold onto the mains plug while pulling the power cable out of the ma...

Page 6: ...ure that extension cables are unrolled completely Make sure that there are no moisture sensitive objects located in the immediate vicinity of the mist nozzle since water may condense near the mist nozzle Filling the water tank The water tank should be filled before first use or when the empty water tank indication 21 lights up Note Fill the device with fresh drinking water only The water temperatu...

Page 7: ... tank 2 8 8 Refit the mist nozzle 14 onto the water tank 2 14 9 Refit the water tank 2 into the device ð In doing so make sure that the arrow points to the front ð Please note that after inserting the water tank the water starts to run into the lower part of the device immediately 10 Set the device up in an upright and stable position ð If the device is not positioned upright the water inside the ...

Page 8: ... 21 22 23 No Designation Description 16 Nebulizer intensity indication Indicates the selected nebulizer intensity during setting Changes dynamically to indicate ongoing operation 17 Segment display Indicates the current relative room humidity Indicates the desired relative room humidity during setting Indicates the number of hours during timer programming 18 Night mode indication Illuminated when ...

Page 9: ... current relative room humidity is shown on the segment display 17 again ð The desired relative room humidity is set Setting the nebulizer intensity The nebulizer intensity can be set in manual humidification mode The default setting is level 2 The nebulizer intensity can be set to 3 levels level 1 low nebulizer intensity level 2 medium nebulizer intensity level 3 high nebulizer intensity 1 Press ...

Page 10: ...ton 29 to switch over to night mode or the Auto button 30 to switch over to automatic mode Night mode The device humidifies the air constantly and regardless of the relative room humidity The timer is automatically set to 8 h The desired relative room humidity and the nebulizer intensity cannot be adjusted in this operating mode The display switches off after approx 5 s and only switches back on w...

Page 11: ...leased ions remove pollen dust viruses and bacteria from the room air Ionization can be switched on in any operating mode 1 Press the Ionizer button 28 to switch ionization on or off ð When ionization is activated the ion indication 22 will be shown on the display Shutdown Warning of electrical voltage Do not touch the mains plug with wet or damp hands Switch off the device Hold onto the mains plu...

Page 12: ...filter cartridge Check the valve in the water tank lid The valve must be able to move freely If necessary clean the water tank Water is leaking Check whether the device is set up in a stable and upright position Check the water level in the lower part of the device The water level might be too high and water is discharged via the overflow Check the valve in the water tank lid The valve must be abl...

Page 13: ...ent screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Clean the water tank Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check the air filter for dirt and foreign objects and clean or replace if necessary ...

Page 14: ...n Stick by Trotec to provide protection from germs in the water The SecoSan Stick prevents the reproduction of germs by means of silver ions Due to the special antimicrobial surface the silver ions are emitted to the immediate proximity of bacteria and germs This way microbial growth can be effectively prevented at the same time the water remains pure and uncontaminated The dosage of the SecoSan S...

Page 15: ... the lid 15 firmly back onto the water tank 2 8 15 Refit the mist nozzle 14 onto the water tank 2 14 16 Refit the water tank 2 into the device In doing so make sure that the arrow points to the front Please note that after inserting the water tank the water starts to run into the inside of the device immediately Cleaning the nebulizer membrane Depending on the hardness of the drinking water used d...

Page 16: ...ater tank 2 Unscrew the lid 15 from the water tank 2 15 8 3 Unscrew the filter cartridge 8 from the lid 15 4 Provide a vessel containing saturated saline solution 5 Place the filter cartridge into the vessel containing saline solution Make sure that the filter cartridge is completely covered by the saline solution 6 Leave the filter cartridge in the saline solution for 24 h 7 Take the filter cartr...

Page 17: ...ompletely Do not insert a wet filter into the device 4 Reinsert the air filter into the device Activities required after maintenance If you want to continue using the device Reconnect the device to the mains If you do not intend to use the device for a considerable time Store the device according to the Storage chapter Technical annex Technical data Parameter Value Model B 5 E Nebulizer performanc...

Page 18: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...