Model
IDFA3E
IDFA4E
24
31
34
12
15
17
IDFA6E
36
46
50
IDFA8E
65
83
91
IDFA11E
80
101
112
Air flow capacity (m
3
/h [ANR])
Outlet air pressure
dew point
3
°
C
7
°
C
10
°
C
Correction factor
1.1
1
0.91
0.83
0.79
IDFA3E
to
11E IDFA15E
to
75E
1.1
1
0.97
0.89
0.77
20
25
30
35
40
Ambient
temperature
Data A: Inlet Air Temperature
Data B: Ambient Temperature
Data C: Inlet Air Pressure
Data D: Air Flow Capacity
Model
IDFA15E
IDFA22E
182
231
254
120
152
168
IDFA37E
273
347
382
IDFA55E
390
432
510
IDFA75E
660
720
822
Air flow capacity (m
3
/h [ANR])
Outlet air pressure
dew point
3
°
C
7
°
C
10
°
C
Note) In case of “Option A (Cool compressed air output)”, the air flow capacity is different. Refer to page 9 for details.
Inlet air
temperature
Correction factor
1.30
1.25
1
0.83
0.7
0.6
5
to
25
30
35
40
45
50
IDFA3E
to
37E
1.33
1.16
1
0.8
0.64
0.48
IDFA55E
to
75E
Inlet air
pressure
(
°
C)
(
°
C)
(MPa)
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1.2
1.4
1.6
0.80
0.87
0.92
0.96
1.00
1.04
1.07
1.1
1.16
1.21
1.25
Correction factor
IDFA3E
to
11E
0.72
0.81
0.88
0.95
1.00
1.06
1.11
1.16
1.21
1.25
1.27
IDFA15E
to
75E
Series
IDFA
쏔
E
Model Selection
IDFA E Selection Example
Read the correction factor.
Obtain the correction factor A to D suitable for your operating
condition using the table below.
The corrected air flow capacity, which considers the user’s operating conditions, is required for selecting
the air dryer. Please select using the following procedures.
1
Calculate the corrected air flow capacity.
Obtain the corrected air flow capacity from the following formula.
Corrected air flow capacity = Air consumption
앦
(Correction
factor A x B x C)
2
Select the model.
Select the model which air flow capacity exceeds the
corrected air flow capacity using the specification table. (For
air flow capacity, refer to the data D below.)
According to the corrected air flow capacity of 48.9 m
3
/h, the
IDFA8E
will
be selected when the required output air pressure dew point is 3
°
C. The
IDFA6E
will be selected when the required pressure dew point is 10
°
C.
3
Option
4
Finalise the model number.
5
Select accessories sold separately.
6
Note) Values obtained from the table below.
Correction factor
Note)
Data symbol
40
°
C
35
°
C
0.5 MPa
31 m
3
/h
A
B
C
—
0.83
0.83
0.92
—
Inlet air temperature
Ambient temperature
Inlet air pressure
Air consumption
Condition
Refer to page 3, 6.
Refer to page 3, 6.
Refer to page 11.
Corrected air flow capacity = 31 m
3
/h
앦
(0.83 x 0.83 x 0.92) = 48.9 m
3
/h
2