HRX-MM-N007
Chapter 4 Service Procedure
4.5 Replacement Procedure
HRS Series
4-46
Be sure to shut off the breaker of the facility power supply (the user’s
machine power supply) before replacement work.
4.5.15 Replacement of DC power supply
<
HRS
-A/W-
>
Table 4-22 Part number of service parts (DC power supply)
Description
Part number
DC power supply
HRS-S0016
Removal
1.
Remove the upper panel, the side panel on the right and the front panel referring the 4.2.1
Removal and the mounting of the panel.
2.
Remove the
connector of DC power supply. (2 locations)
3.
Hold the spacer (4 locations) to remove DC power supply.
Fig. 4.5-34 Removal of DC power supply
2.
Connector
2.
Connector
3.
Spacer (4 locations)
3.
Removal of spacer
Spacer
DC power supply