background image

Polyester band

Cardboard box

Wooden skid

24

Be sure to read this before handling the products. Refer to the back cover for safety instructions. 
For temperature control equipment precautions, refer to the “Handling Precautions for SMC 
Products” and the “Operation Manual” on the SMC website: http://www.smc.eu

HRR 

Series

Specifi c Product Precautions 1

Design

Warning

1. This catalogue shows the specifi cations of a single unit.

1)  Check the specifi cations of the single unit (contents of this 

catalogue) and thoroughly consider the adaptability between 
the user’s system and this unit.

2)  Although the protection circuit as a single unit is installed, 

prepare a drain pan, water leakage sensor, discharge air 
facility, and emergency stop equipment, depending on the 
user’s operating condition. Also, the user is requested to 
carry out the safety design for the whole system.

2. When attempting to cool areas that are open to the 

atmosphere (tanks, pipes), plan your piping system 
accordingly.

When cooling open-air external tanks, arrange the piping so that 
there are coil pipes for cooling inside the tanks, and to carry 
back the entire fl ow volume of circulating fl uid that is released.

3.  Use non-corrosive material for fl uid contact parts of 

circulating fl uid.

The recommended circulating fluid is the tap water or 15% 
ethylene glycol aqueous solution. Using corrosive materials 
such as aluminium or iron for fl uid contact parts such as piping 
may cause clogging or leakage in the circulating fl uid circuit. 
Therefore, take suffi cient care when selecting fl uid contact part 
materials such as piping.

4.  Design the piping so that no foreign matter enter 

the chiller.

If foreign matter such as scales in the piping enter the circulat-
ing fl uid, this may cause the pump to malfunction. 

Selection

Warning

1. Model selection

For selecting a model of thermo-chiller, it is required to know 
the heat generation amount of the user’s equipment. Obtain 
the heat generation amount, referring to “Cooling Capacity 
Calculation” on pages 22 and 23 before selecting a model.

Handling

Warning

1. Thoroughly read the Operation Manual.

Read the Operation Manual completely before operation, and 
keep this manual available whenever necessary.

Warning

1.  This product is heavy. Pay attention to safety and 

position of the product when it is transported, 
carried and moved.

2.  Read the Operation Manual carefully to move the 

product after unpacking.

Caution

1.  Never put the product down sideway as this may 

cause failure.

The product will be delivered in the packaging shown below.

Transportation / Carriage / Movement

Model

Weight [kg]

1

Dimensions [mm]

HRR012-A
HRR018-A

54

Height 575 x Width 610 x Depth 820

HRR012-W
HRR018-W

55

HRR024-A
HRR030-A

61

Height 665 x Width 610 x Depth 820

HRR024-W
HRR030-W

60

1  For models with an option, the weights are increased as below.

Option

Description

Additional weight

DM

With electric conductivity control function, 
Applicable to DI water piping

+1 kg

M

Applicable to DI water piping

Not changed

T

High-pressure pump mounted

+5 kg

Summary of Contents for HRR Series

Page 1: ...bility Single phase 200 to 230 VAC 50 60 Hz Global power supply 1 0 1 6 2 0 2 5 kW 50 Hz Air cooled Refrigeration Cooling capacity DI filter Option Particle filter Standard Bypass valve Standard 310 m...

Page 2: ...duct Optional Accessories Optional Accessories Cap Drain port Rc1 4 Water leakage sensor Drain pan Handle Accessory Replacement particle filter element DI filter replacement Drain pan Built in water l...

Page 3: ...Set value displayed in green Set temperature etc is displayed Easy check from the circulation fluid level HRS012 HRR012 HRR012 HRS012 615 mm 310 mm Flow rate and pressure adjustment can be seen on th...

Page 4: ...opens and closes to keep the refrigerant gas pressure consistent The facility water flow rate is controlled by the water regulating valve Facility water circuit Circulating fluid circuit Refrigeration...

Page 5: ...LEVEL a WRN Alternately displayed Maintenance notification number MT01 X is displayed if a maintenance notification has occurred To menu screen REF a TEMP Alternately displayed Compressor inlet temper...

Page 6: ...d can be output Remote operation signal input Chiller can be operated remotely by contact input signals Output setting example Output 1 Temperature rise Output 2 Pressure rise Output 3 Operation statu...

Page 7: ...wave inspection machine Transmission cable connector for fibre laser Cooling of the laser irradiated part Temperature control of the X ray tube and X ray light sensing part Cooling of the UV lamp X r...

Page 8: ...on Water cooled Refrigeration HRR Series Pressure Switch Monitors pressure of the circulating fluid and facility water ISE20C ISE7 G 3 Screen Display High Precision Digital Pressure Switch PSE300AC PS...

Page 9: ...Alarm p 16 Communication Functions p 17 Thermo chiller Rack Mount Type HRR Series Options With Electric Conductivity Control Function Applicable to DI Water Piping p 19 Applicable to DI Water Piping...

Page 10: ...pressure pump mounted U Conforming to UL Standards When multiple options are combined indicate symbols in alphabetical order Water cooledRefrigeration HRR U W 20 Pipe thread type Rc F G With Rc G conv...

Page 11: ...of the Japan Refrigeration and Air Conditioning Industry Association JRA GL 02 1994 cooling water system circulating type make up wa ter 3 q Ambient temperature 2 5 C w Circulating fluid temperature 2...

Page 12: ...e 2 If tap water is used use water that conforms to Water Quality Standards of the Japan Refrigeration and Air Conditioning Industry Association JRA GL 02 1994 cooling water system circulating type ma...

Page 13: ...1500 1000 500 0 Ambient temperature or facility water temperature 32 C 25 C 40 C Circulating fluid temperature C Cooling capacity W 0 10 20 30 40 3500 3000 2500 2000 1500 1000 500 0 Ambient temperatur...

Page 14: ...emperature or facility water temperature 40 C 32 C 25 C 5 C Circulating fluid flow rate l min Circulating fluid pressure MPa 0 5 10 15 20 25 0 3 0 2 0 1 0 Outlet 60 Hz Outlet 50 Hz Return port Allowab...

Page 15: ...connector Product label Circulating fluid outlet Rc1 2 226 73 424 397 Ventilation air outlet Ventilation air inlet 361 4 259 8 139 1 37 5 0 86 10 440 Includes protruding parts 550 50 Maintenance port...

Page 16: ...r Inside of the cover panel 210 38 0 424 397 164 5 140 5 0 272 5 183 6 126 4 37 5 0 440 Includes protruding parts 550 24 50 Maintenance port Power supply switch Operation display Fluid level gauge 10...

Page 17: ...9 key Move item downward or decrease the set value 0 RESET key Reset the alarm Alarm code Alarm message Initial value Display unit Upper stage White Lower stage Green AL01 Low level in tank abnormal F...

Page 18: ...pplication Division Initial value Default setting 1 24 VDC output Output 2 24 VDC output Output 3 24 VDC output Output 4 Contact input signal 1 Input OFF 5 Common of contact output signal 1 Output 6 C...

Page 19: ...D 3 SG 5 This product RD 2 SD 3 SG 5 D sub 9 pin female socket type Communication connector 5 1 9 6 Run Stop Circulating fluid temperature setting Writing Circulating fluid discharge temperature Circu...

Page 20: ...ng fluid circuit is made from non copper materials Available DI water is electric conductivity 2 S cm or more Electric resistivity 0 5 M cm or less This Option M does not have electric resistance elec...

Page 21: ...p Capacity HRR012 018 024 030 20 MT HRR012 018 024 030 20 T Applicable model HRR012 018 024 030 20 T HRR012 018 024 030 20 MT 1 Pump Rated flow 50 60 Hz 2 3 l min 10 0 42 MPa 14 0 40 MPa 10 0 32 MPa 1...

Page 22: ...rtridge Element for the maintenance of the particle filter for circulating fluid DI filter cartridge for replacement for Option DM Electric conductivity control type DI water piping type Part number A...

Page 23: ...ser s equipment Q qm x C x T2 T1 x qv x C x T 60 1 x 10 x 4 2 x 103 x 2 0 60 1400 J s 1400 W Cooling capacity Considering a safety factor of 20 1400 W x 1 2 1680 W Heat generation amount by user s equ...

Page 24: ...the circulating fluid discharge pressure Consider the installation height difference between the thermo chiller and the user s equipment and the piping resistance such as circulating fluid pipings or...

Page 25: ...arts such as piping may cause clogging or leakage in the circulating fluid circuit Therefore take sufficient care when selecting fluid contact part materials such as piping 4 Design the piping so that...

Page 26: ...he descriptions in the ta ble below Select the thermo chiller considering the descriptions qUpper limit of ambient temperature Use the product in ambient temperature of the described value or low er a...

Page 27: ...be connected to a water line gas line or lightning rod HRR Series Specific Product Precautions 3 Mounting Installation Warning 1 Do not use the product outdoors 2 Do not place heavy objects on top of...

Page 28: ...iping due to metal ion 5 Do not use fluid that includes metric powers and other foreign materials It can cause issues clogging of the circulating fluid circuit or leakage Warning HRR Series Specific P...

Page 29: ...er once again when the fluid level is reduced When there is no reduction in the fluid level the job of removing the air is completed 2 Confirmation during operation Check the circulating fluid tempera...

Page 30: ......

Page 31: ...nergy railways air navigation space shipping vehicles military medical treatment combustion and recreation or equipment in contact with food and beverages emergency stop circuits clutch and brake circ...

Reviews: