background image

(UL Standards)

Space Saving

Multiple chillers can be 
mounted to a 19-inch rack.

1   Details for 19-inch rack, refer to page 1.

Operable without the need to 
remove the unit from the rack

Front Access

Simple to control, service and 
maintain with all filters and 
drainage via the front panel

±

0.1 

°

C

Temperature stability

Single-phase

200

to

230 VAC

(50/60 Hz)

Global power supply

1.0/1.6/2.0/2.5 kW 

(50 Hz)

Air-cooled Refrigeration

Cooling capacity

DI fi lter 

(Option)

Particle fi lter 

(Standard)

Bypass valve 

(Standard)

310

 mm

399

 mm

Fluid fi ll port

Drain port

Bypass valve 

(Standard)

ption)

Particle fi lter 

(Standard)

DI filter 

(Op

Equivalent to 9U

(EIA Standards

1

)

Equivalent to 7U

(EIA Standards

1

)

Water-cooled Refrigeration

Circulating Fluid Temperature Controller

Thermo-chiller/Rack Mount Type

HRR

 Series

CAT.EUS40-66A-UK

New

New

Summary of Contents for HRR Series

Page 1: ...bility Single phase 200 to 230 VAC 50 60 Hz Global power supply 1 0 1 6 2 0 2 5 kW 50 Hz Air cooled Refrigeration Cooling capacity DI filter Option Particle filter Standard Bypass valve Standard 310 m...

Page 2: ...duct Optional Accessories Optional Accessories Cap Drain port Rc1 4 Water leakage sensor Drain pan Handle Accessory Replacement particle filter element DI filter replacement Drain pan Built in water l...

Page 3: ...Set value displayed in green Set temperature etc is displayed Easy check from the circulation fluid level HRS012 HRR012 HRR012 HRS012 615 mm 310 mm Flow rate and pressure adjustment can be seen on th...

Page 4: ...opens and closes to keep the refrigerant gas pressure consistent The facility water flow rate is controlled by the water regulating valve Facility water circuit Circulating fluid circuit Refrigeration...

Page 5: ...LEVEL a WRN Alternately displayed Maintenance notification number MT01 X is displayed if a maintenance notification has occurred To menu screen REF a TEMP Alternately displayed Compressor inlet temper...

Page 6: ...d can be output Remote operation signal input Chiller can be operated remotely by contact input signals Output setting example Output 1 Temperature rise Output 2 Pressure rise Output 3 Operation statu...

Page 7: ...wave inspection machine Transmission cable connector for fibre laser Cooling of the laser irradiated part Temperature control of the X ray tube and X ray light sensing part Cooling of the UV lamp X r...

Page 8: ...on Water cooled Refrigeration HRR Series Pressure Switch Monitors pressure of the circulating fluid and facility water ISE20C ISE7 G 3 Screen Display High Precision Digital Pressure Switch PSE300AC PS...

Page 9: ...Alarm p 16 Communication Functions p 17 Thermo chiller Rack Mount Type HRR Series Options With Electric Conductivity Control Function Applicable to DI Water Piping p 19 Applicable to DI Water Piping...

Page 10: ...pressure pump mounted U Conforming to UL Standards When multiple options are combined indicate symbols in alphabetical order Water cooledRefrigeration HRR U W 20 Pipe thread type Rc F G With Rc G conv...

Page 11: ...of the Japan Refrigeration and Air Conditioning Industry Association JRA GL 02 1994 cooling water system circulating type make up wa ter 3 q Ambient temperature 2 5 C w Circulating fluid temperature 2...

Page 12: ...e 2 If tap water is used use water that conforms to Water Quality Standards of the Japan Refrigeration and Air Conditioning Industry Association JRA GL 02 1994 cooling water system circulating type ma...

Page 13: ...1500 1000 500 0 Ambient temperature or facility water temperature 32 C 25 C 40 C Circulating fluid temperature C Cooling capacity W 0 10 20 30 40 3500 3000 2500 2000 1500 1000 500 0 Ambient temperatur...

Page 14: ...emperature or facility water temperature 40 C 32 C 25 C 5 C Circulating fluid flow rate l min Circulating fluid pressure MPa 0 5 10 15 20 25 0 3 0 2 0 1 0 Outlet 60 Hz Outlet 50 Hz Return port Allowab...

Page 15: ...connector Product label Circulating fluid outlet Rc1 2 226 73 424 397 Ventilation air outlet Ventilation air inlet 361 4 259 8 139 1 37 5 0 86 10 440 Includes protruding parts 550 50 Maintenance port...

Page 16: ...r Inside of the cover panel 210 38 0 424 397 164 5 140 5 0 272 5 183 6 126 4 37 5 0 440 Includes protruding parts 550 24 50 Maintenance port Power supply switch Operation display Fluid level gauge 10...

Page 17: ...9 key Move item downward or decrease the set value 0 RESET key Reset the alarm Alarm code Alarm message Initial value Display unit Upper stage White Lower stage Green AL01 Low level in tank abnormal F...

Page 18: ...pplication Division Initial value Default setting 1 24 VDC output Output 2 24 VDC output Output 3 24 VDC output Output 4 Contact input signal 1 Input OFF 5 Common of contact output signal 1 Output 6 C...

Page 19: ...D 3 SG 5 This product RD 2 SD 3 SG 5 D sub 9 pin female socket type Communication connector 5 1 9 6 Run Stop Circulating fluid temperature setting Writing Circulating fluid discharge temperature Circu...

Page 20: ...ng fluid circuit is made from non copper materials Available DI water is electric conductivity 2 S cm or more Electric resistivity 0 5 M cm or less This Option M does not have electric resistance elec...

Page 21: ...p Capacity HRR012 018 024 030 20 MT HRR012 018 024 030 20 T Applicable model HRR012 018 024 030 20 T HRR012 018 024 030 20 MT 1 Pump Rated flow 50 60 Hz 2 3 l min 10 0 42 MPa 14 0 40 MPa 10 0 32 MPa 1...

Page 22: ...rtridge Element for the maintenance of the particle filter for circulating fluid DI filter cartridge for replacement for Option DM Electric conductivity control type DI water piping type Part number A...

Page 23: ...ser s equipment Q qm x C x T2 T1 x qv x C x T 60 1 x 10 x 4 2 x 103 x 2 0 60 1400 J s 1400 W Cooling capacity Considering a safety factor of 20 1400 W x 1 2 1680 W Heat generation amount by user s equ...

Page 24: ...the circulating fluid discharge pressure Consider the installation height difference between the thermo chiller and the user s equipment and the piping resistance such as circulating fluid pipings or...

Page 25: ...arts such as piping may cause clogging or leakage in the circulating fluid circuit Therefore take sufficient care when selecting fluid contact part materials such as piping 4 Design the piping so that...

Page 26: ...he descriptions in the ta ble below Select the thermo chiller considering the descriptions qUpper limit of ambient temperature Use the product in ambient temperature of the described value or low er a...

Page 27: ...be connected to a water line gas line or lightning rod HRR Series Specific Product Precautions 3 Mounting Installation Warning 1 Do not use the product outdoors 2 Do not place heavy objects on top of...

Page 28: ...iping due to metal ion 5 Do not use fluid that includes metric powers and other foreign materials It can cause issues clogging of the circulating fluid circuit or leakage Warning HRR Series Specific P...

Page 29: ...er once again when the fluid level is reduced When there is no reduction in the fluid level the job of removing the air is completed 2 Confirmation during operation Check the circulating fluid tempera...

Page 30: ......

Page 31: ...nergy railways air navigation space shipping vehicles military medical treatment combustion and recreation or equipment in contact with food and beverages emergency stop circuits clutch and brake circ...