Caution

SMC products are not intended for use as instruments for legal 

metrology.

Measurement  instruments  that  SMC  manufactures  or  sells  have  not  been 

qualified by type approval tests relevant to the metrology (measurement) laws 

of  each  country.  Therefore,  SMC  products  cannot  be  used  for  business  or 

certification ordained by the metrology (measurement) laws of each country.

Compliance Requirements

1) ISO 4414: Pneumatic fluid power – General rules relating to systems.

  ISO 4413: Hydraulic fluid power – General rules relating to systems.

  IEC 60204-1: Safety of machinery – Electrical equipment of machines.

 

(Part 1: General requirements)

  ISO 10218-1: Manipulating industrial robots – Safety.

  etc.

Caution

 indicates a hazard with a low level of risk which, 

if not avoided, could result in minor or moderate injury.

Caution:

Warning

 indicates a hazard with a medium level of risk which, 

if not avoided, could result in death or serious injury.

Warning:
Danger :

Danger

 indicates a hazard with a high level of risk which, 

if not avoided, will result in death or serious injury.

Warning

Caution

1. The  compatibility  of  the  product  is  the  responsibility  of  the 

person  who  designs  the  equipment  or  decides  its 

specifications.

Since the product specified here is used under various operating conditions, 

its compatibility with specific equipment must be decided by the person who 

designs  the  equipment  or  decides  its  specifications  based  on  necessary 

analysis and test results. The expected performance and safety assurance 

of the equipment will be the responsibility of the person who has determined 

its  compatibility  with  the  product.  This  person  should  also  continuously 

review  all  specifications  of  the  product  referring  to  its  latest  catalog 

information,  with  a  view  to  giving  due  consideration  to  any  possibility  of 

equipment failure when configuring the equipment.

2. Only  personnel  with  appropriate  training  should  operate 

machinery and equipment.

The product specified here may become unsafe if handled incorrectly. The 

assembly, operation and maintenance of machines or equipment including 

our products must be performed by an operator who is appropriately trained 

and experienced.

3. Do not service or attempt to remove product and machinery/

equipment until safety is confirmed.

1. The inspection and maintenance of machinery/equipment should only be 

performed  after  measures  to  prevent  falling  or  runaway  of  the  driven 

objects have been confirmed. 

2. When the product is to be removed, confirm that the safety measures as 

mentioned above are implemented and the power from any appropriate 

source is cut, and read and understand the specific product precautions 

of all relevant products carefully.

3. Before  machinery/equipment  is  restarted,  take  measures  to  prevent 

unexpected operation and malfunction.  

4. Contact  SMC  beforehand  and  take  special  consideration  of 

safety  measures  if  the  product  is  to  be  used  in  any  of  the 

following conditions. 

 

1. Conditions and environments outside of the given specifications, or use 

outdoors or in a place exposed to direct sunlight.

2. Installation on equipment in conjunction with atomic energy, railways, air 

navigation,  space,  shipping,  vehicles,  military,  medical  treatment, 

combustion  and  recreation,  or  equipment  in  contact  with  food  and 

beverages,  emergency  stop  circuits,  clutch  and  brake  circuits  in  press 

applications,  safety  equipment  or  other  applications  unsuitable  for  the 

standard specifications described in the product catalog. 

3. An application which could have negative effects on people, property, or 

animals requiring special safety analysis. 

4. Use in an interlock circuit, which requires the provision of double interlock 

for  possible  failure  by  using  a  mechanical  protective  function,  and 

periodical checks to confirm proper operation.

1. The product is provided for use in manufacturing industries.

The  product  herein  described  is  basically  provided  for  peaceful  use  in 

manufacturing industries. 

If considering using the product in other industries, consult SMC beforehand 

and exchange specifications or a contract if necessary. 

If anything is unclear, contact your nearest sales branch.

Limited warranty and Disclaimer/

Compliance Requirements

The product used is subject to the following “Limited warranty and Disclaimer” and 

“Compliance Requirements”.

Read and accept them before using the product.

Limited warranty and Disclaimer

1. The warranty period of the product is 1 year in service or 1.5 years after 

the product is delivered, whichever is first.

2)

Also,  the  product  may  have  specified  durability,  running  distance  or 

replacement parts. Please consult your nearest sales branch.

2. For any failure or damage reported within the warranty period which is clearly our 

responsibility, a replacement product or necessary parts will be provided. 

This limited warranty applies only to our product independently, and not to any 

other damage incurred due to the failure of the product.

3. Prior to using SMC products, please read and understand the warranty terms 

and disclaimers noted in the specified catalog for the particular products.

2) Vacuum pads are excluded from this 1 year warranty.

A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. 

Also, even within the warranty period, the wear of a product due to the use of the vacuum pad 

or failure due to the deterioration of rubber material are not covered by the limited warranty.

1. The  use  of  SMC  products  with  production  equipment  for  the  manufacture  of 

weapons of mass destruction (WMD) or any other weapon is strictly prohibited.

2. The exports of SMC products or technology from one country to another are 

governed by the relevant security laws and regulations of the countries involved 

in the transaction. Prior to the shipment of a SMC product to another country, 

assure that all local rules governing that export are known and followed.

These  safety  instructions  are  intended  to  prevent  hazardous  situations  and/or 

equipment damage. These instructions indicate the level of potential hazard with 

the labels of “Caution,” “Warning” or “Danger. They are all important notes for 

safety  and  must  be  followed  in  addition  to  International  Standards  (ISO/IEC)

1)

and other safety regulations.

Safety Instructions

unit

m
mm
g
cm

3

L
mm/s

result

psi
psi
°F
ft-lb
lbf
cfm

conversion

x 3.28
x 0.04
x 0.04
÷ 16.387
x 61.024
÷ 25.4

length

mass
volume

speed

unit

MPa
kPa
°C
N∙m
N
L/min

result

psi
psi
°F
ft-lb
lbf
cfm

conversion

x 145
÷ 6.895
x1.8 then add 32
x 0.738
÷ 4.448
÷ 28.317

pressure

temperature
torque
force
flow

U N I T   C O N V E R S I O N S

Summary of Contents for HRL Series

Page 1: ...Cooling capacity kW 9 19 26 CH1 Oscillator 1 Max 1 5 CH2 Optical system Temperature stability C 0 1 0 5 Set temperature range C 15 to 25 20 to 40 1 1 CH2 CH1 CH2 CH1 HRSH200 HRL200 HRS012 Dual thermo...

Page 2: ...with a general refrigerant circuit that controls the compressor by turning the power ON OFF and with a bypass to the circulating uid circuit 1 For HRL300 A 20 mm Space saving Reduced wiring labor Keep...

Page 3: ...emperature difference as high temperature stability can be achieved even with a small size tank This also contributes to space saving One compressor controls 2 channels which realize the independent t...

Page 4: ...screen Set values can be entered from the touch panel Model Cooling method Cooling capacity Power supply Function Accessories CH1 CH2 HRL100 Air cooled refrigeration 9 kW 1 kW Max 1 5 kW 3 phase 200...

Page 5: ...ssigned for specified type of signals Ex 1 Ex 2 Ex 3 Circulating fluid temperature setting Start and stop Circulating fluid discharge temperature Circulating fluid discharge pressure Run and stop stat...

Page 6: ...perating time of a fan Usage time of a DI filter Usage time of a dustproof filter Operation time of a chiller Improved usability and visibility When any alarm is generated the screen automatically mov...

Page 7: ...option Only 200V as an option HRSH Inverter type 0 1 5 to 35 Outdoor installation IPX4 400V as standard 200V as an option Only 200V as an option HRL Inverter dual type CH1 0 1 15 to 25 9 kW 19 kW 26 k...

Page 8: ...F2 200 Pressure Sensor for General Fluids PSE56 Pressure Sensor Controller PSE200 300 300AC Refer to the Web Catalog for details S Coupler KK Series T TU TH TD TL TLM Material Nylon Polyurethane FEP F...

Page 9: ...ommended External Piping Flow p 14 Cable Specifications p 14 Operation Display Panel p 15 Alarm p 15 Communication Functions p 16 Optional Accessories p 19 Cooling Capacity Calculation Required Coolin...

Page 10: ...PBT POM PU PC PVC EPDM NBR CH2 Stainless steel Alumina ceramic Carbon Fluororesin PP PBT POM PU PVC PPS AS PS EPDM NBR Ion replacement resin Electrical system Power supply 3 phase 200 VAC 50 Hz 3 pha...

Page 11: ...id temperature C Cooling capacity kW 35 30 25 20 15 10 5 0 Ambient temperature 32 C Ambient temperature 45 C Cooling capacity kW Circulating fluid temperature C 0 0 0 5 1 0 1 5 2 0 2 5 3 0 20 30 40 Am...

Page 12: ...r for Lasers Anchor bolt mounting position View A Ventilation air outlet Ventilation air inlet Ventilation air inlet A 677 627 330 10 954 1538 40 or less 715 984 1026 HRL100 A 20 Dimensions For piping...

Page 13: ...Thermo chiller for Lasers HRL Series Anchor bolt mounting position View A 715 40 or less 954 330 10 1538 984 1026 677 627 Ventilation air outlet Ventilation air inlet Ventilation air inlet A HRL200 A...

Page 14: ...r Lasers Anchor bolt mounting position View A Ventilation air outlet Ventilation air inlet 850 40 or less 1079 330 10 1839 1109 1145 750 700 A Ventilation air inlet HRL300 A 20 Dimensions For piping p...

Page 15: ...0 VAC 60 Hz M5 R5 5 5 4 cores x 5 5 mm2 4 cores x AWG 10 including grounding cable 30 30 HRL200 A 20 R8 5 4 cores x 8 mm2 4 cores x AWG 8 including grounding cable 40 HRL300 A 20 50 An example of the...

Page 16: ...normal rise of circulating uid temperature AL10 CH1 High Temp CH1 circulating uid temperature rise AL11 CH1 Low Temp CH1 circulating uid temperature drop AL12 CH1 TEMP READY Alarm CH1 TEMP READY alarm...

Page 17: ...make sure that the total load current is 200 mA or less User s system side To the thermo chiller 24 VDC 15 V 100 ANALOG COM 24 COM 1 24 COM 24 VDC Output 4 7 k 4 7 k 4 7 k 15 V 15 V 100 15 V ANALOG C...

Page 18: ...11 Analog output signal 1 Output CH2 circulating fluid temperature 1 12 None Cannot be connected 3 13 None Cannot be connected 3 14 24 COM output Common of contact input signal Output 15 Common of con...

Page 19: ...his product 31st slave SD SD SG 2 SD 7 SD 5 SG This product 1st slave 2 SD 7 SD 5 SG 2 SD 7 SD 5 SG Do not connect with other pins Standards RS 232C Circuit diagram One thermo chiller for one master M...

Page 20: ...ed per unit HRS S0214 Dustproof lter Upper 1 For HRL100 200 A 2 pcs are used per unit HRS S0185 Dustproof lter 1 For HRL300 A 4 pcs are used per unit HRS PF006 Particle lter element 1 Common to each m...

Page 21: ...60 s min 1 Refer to page 21 for the typical physical property value of tap water or other circulating uids Q qm x C x T2 T1 19535 J s 19535 W 19 5 kW Cooling capacity Considering a safety factor of 20...

Page 22: ...pump capacity curves Check beforehand if the circulating uid pipings or circulating uid circuit of the user s equipment are fully durable against this pressure Circulating Fluid Typical Physical Prop...

Page 23: ...uid are not left inside the pipings During operation Air cooled type 2 C to 45 C 5 In locations where condensation may occur 6 In locations which receive direct sunlight or radiated heat 7 In location...

Page 24: ...enough for it to come out the other side 3 Be careful not to bump the fork to the cover panel or piping ports Transportation Carriage Movement Warning 3 Hanging transportation 1 Crane manipulation and...

Page 25: ...it may become impossible to circulate the circulating uid Proceed with caution Mounting Installation Caution 3 Refer to the Operation Manual for this product and secure an installation space that is...

Page 26: ...system Circulation type Make up water Item Unit Standard value In uence Corrosion Scale generation Standard item pH at 25 C 6 0 to 8 0 Electric conductivity 25 C S cm 100 1 to 300 1 Chloride ion Cl m...

Page 27: ...Caution If operating in the conditions below the protection circuit will activate and an operation may not be performed or will stop Power supply voltage is not within the rated voltage range of 10 I...

Page 28: ...r in a place exposed to direct sunlight 2 Installation on equipment in conjunction with atomic energy railways air navigation space shipping vehicles military medical treatment combustion and recreati...

Reviews: