SAFETY ( continued )

Follow the instructions given below when handling your reduced wiring system.
Otherwise a damage or failure to cause a malfunction can result.

Operate the reduced wiring system at the specified voltage.

Reserve space for maintenance.

Do not remove any name plate or label.

Do not drop, hit or apply an excessive shock to the unit.

Follow the specified tightening torque.

Do not apply any excessive force to cables by repeated bending, tensioning or placing a

heavy object on the cables.

Connect wires and cables correctly.

Do not perform any wiring work while the power is on.

Do not use the reduced wiring system on the same wiring route as the power line or high

voltage line.

Confirm the insulation of wiring.

Perform the power supply wiring by dividing into two lines ----  one is for power supply for out-

put and the other is for power supply for input and controlling GW/SI.

Take sufficient measures against noise such as noise filter when incorporating the reduced

wiring system into a machine or equipment.

Connect the shield wire of the dedicated cable for CC-Link to "SLD" of each unit. 

Mount a terminal plug or a waterproof cap on each unused M12 connector for input/output

( communication connector, communication ports A - D, and power supply for input and

controlling GW/SI ).

Take sufficient shielding measures when operating the product in any of the following places.

( 1 ) A place where noise due to static electricity etc. is generated

( 2 ) A place of high electric field strength

( 3 ) A place where exposure to radioactivity is possible

( 4 ) A place near power cable

Do not operate the product in a place where there is a source of surge.

Use a surge absorbing element built-in type to directly drive the load that generates surge

voltage such as solenoid valve.

Prevent any foreign matter such as remnant of wires from getting inside the product when

opening the station number switch protective cover.

Install the reduced wiring system in a place free from vibration and impact.

Operate the product in the specified ambient temperature range.

Do not use in a place to be affected by the radiant heat from a surrounding heat source.

Set the DIP switch and rotary switche by using a sharp-pointed watchmakers screwdriver

etc.

Perform the maintenance regularly.

Conduct an appropriate functional inspection after completing the maintenance.

Do not use chemicals such as benzin and thinner to clean the product.

Product Summary

System configuration

GW unit

Manifold valve 
with SI unit
( SV/VQC series )

Input unit
manifold

BUS adapter

Power supply
connector cable
( DC24V for solenoid
valves/output, DC24V for
input and controlling GW/SI ) 

Branch cable
with M12 connector

Branch cable
with M12 connector

Input unit manifold

Manifold valve
with SI unit
( SV/VQC series )

The reduced wiring system is connected to various kinds of fieldbus and realizes the
reduced wiring and decentralized installation of I/O devices . The signals to/from
fieldbus are exchanged by GW unit, and the signals to/from decentralized I/O devices
are collected and delivered by GW unit.
The maximum number of connections of manifold valve/Input unit manifold is
16/branch x 4 branches = 64 points each for output and input.

As the cables with connectors are used for all wiring between devices, the system
complies with the IP65 environment.

Summary of Contents for EX500 Series

Page 1: ...Reduced wiring system EX500 GMJ1 Instruction Manual CC Link Compatible GW Unit URL http www smcworld com EX OMI0026...

Page 2: ...pecification 24 Display 25 Input Unit Manifold Part Names 26 Dimensions 27 Installation 28 Specification 29 Wiring 30 Display 31 EX9 Series General Purpose Output Block Part Names 32 Dimensions 33 Mou...

Page 3: ...system by adding different type of protection such as mechanical protection Check that the interlock circuit is working normally Otherwise accident caused by malfunction can result Before performing...

Page 4: ...ace near power cable Do not operate the product in a place where there is a source of surge Use a surge absorbing element built in type to directly drive the load that generates surge voltage such as...

Page 5: ...d valve for input devices such as sensor and for controlling GW SI by using power supply connector cable Note1 Display the power supply status and communication status with PLC Note2 Station number sw...

Page 6: ...branch total extended length 10m or less Number of stations occupied Station type 3 stations Remote device station Transmission speed 156kbps 625kbps 2 5Mbps 5Mbps 10Mbps Cable length between stations...

Page 7: ...this EX500 is the terminal of CC Link connection connect the terminal resistor Refer to Connection of terminal resistor page 12 in this manual Avoid the mixing of CC Link dedicated high performance c...

Page 8: ...Gray Wiring continued Power supply wiring Connect the power supply connector cable to the power supply connector of GW unit There are two types of cables different in connector shape straight type and...

Page 9: ...nnector Power supply connector 1 3 4 5 2 1 3 4 5 2 A Two power supply system B Single power supply system Branch wiring wiring to communication ports For wiring with solenoid valves or input devices c...

Page 10: ...unit for SV VQC series Connector C1 0 Branch cable with M12 connector Connector C2 1 Input unit manifold Manifold valve with SI unit for SV VQC series Terminal plug NOTE When no Input unit is connecte...

Page 11: ...has no received data Lights on COM D is receiving data Lights off COM D has no received data Display Description NOTE When connecting manifold valve only without connecting Input unit manifold LEDs o...

Page 12: ...ate solenoid valves relays etc in combination with EX9 series general purpose output block For how to use it refer to section EX9 Series General Purpose Output Block page 32 in this manual SI unit for...

Page 13: ...dually Note 1 For mounting installation methods of solenoid valve manifold etc refer to the catalogs instruction manuals technical data etc of each valve series When connecting general purpose output...

Page 14: ...alve series Cassette Tie rod 40 50 63 80 100 125 Series Manifold Inner diameter of applicable cylinder tube mm Max 8 stations Single solenoid valve General purpose output block EX500 Q 02 only Max 16...

Page 15: ...ector 5 Connects with sensor Note1 Indicator LED 6 Indicates sensor signal status Note2 Marker 7 To be used for writing input No etc End block 8 Completes the end of Input unit manifold DIN rail 9 To...

Page 16: ...2 3 4 5 6 7 8 Specification Specifications for Input unit Connected block Current source type input block PNP input block or Current sink type input block NPN input block Connected block stations Max...

Page 17: ...onnecting sensors confirm the specification of output signal carefully Otherwise malfunction can result The key position for mounting sensor connector is as shown to the right Consider this key positi...

Page 18: ...eries SI unit for VQC series EX500 Q 02 Output connector 1 Connects with output device Note1 Indicator LED 2 Indicates the output status Note2 Part name No Application Note1 For wiring method refer to...

Page 19: ...f output block stations 1 2 3 4 5 6 7 8 The above dimensions indicate when one unit of power block width 21mm is combined For details refer to the instruction manuals technical data etc of EX9 series...

Page 20: ...output devices DC24V Power supply for output devices DC24V 2 Power supply for output devices 0V Power supply for output devices 0V 3 4 5 Power supply for sensor DC24V Power supply for sensor 0V Groun...

Page 21: ...is unused If this terminal plug is not used COM LED of GW unit does not light on EX500 AC000 S How to order 1 7 6 5 4 3 2 8 M12 16 44 7 Plug Connector Pin Layout Waterproof cap Mounted on unused ports...

Page 22: ...to the branch of unlit COM port and the branch cable with M12 connector is connected to the Input unit When connecting no Input unit connect a terminal plug Item No Solution Corrective action PWR LED...

Reviews: