24
25
Specification
1. SI unit for SV series valve ( EX500-S
01 )
Connected block
Solenoid valve ( single, double )
Relay output module ( 1-point output, 2- point output )
Connected
block stations
Double solenoid valve
Relay output module ( 2-point output )
Supply voltage for block
DC24V
Supply current for block
0.65A Max.
Current consumption
100mA or less ( at rated voltage )
Single solenoid valve
Relay output module ( 1-point output )
Max. 8 stations
Max. 16 stations
Item
Specification
2. SI unit for VQC series valve ( EX500-Q
)
Connected block
Solenoid valve ( single, double )
General purpose output block ( EX500-Q
02 only )
Connected
block stations
Supply voltage for block
Supply current for block
Current consumption
Double solenoid valve
Item
Specification
3. Applicable valve series
Cassette
Tie-rod
40
50
63
80
100
125
Series
Manifold
Inner diameter of applicable cylinder tube ( mm )
Max. 8 stations
Single solenoid valve
General purpose output block
( EX500-Q
02 only )
Max. 16 stations
Max. 8 stations
DC24V
0.75A Max.
100mA or less ( at rated voltage )
SV1000
SV2000
SV3000
-
-
-
-
-
SV4000
VQC1000
VQC2000
VQC4000
For detailed specifications of solenoid valve and manifold, refer to the catalogs, instruction
manuals, technical data, etc. of each valve series.
Power LED
Communication LED
SI unit for SV series valves ( EX500-S
01 )
Power LED
Communication LED
SI unit for VQC series valves ( EX500-Q
)
Power LED
Lights on: Power to solenoid valves/output is supplied at the
specified voltage.
Lights off: Power to solenoid valves/output is not supplied at
the specified voltage. ( Voltage dropped to lower
than 20V. )
Communication
LED
Lights on: Receiving data from GW
Lights off: No received data
Display
Description
Display
Common to EX500-S
01/EX500-Q