![background image](http://html1.mh-extra.com/html/smc-networks/ex120-sdn1-x2/ex120-sdn1-x2_operation-manual_1300551029.webp)
-28-
No.EX##-OME0015-C
7. Parameter Object (Class ID: 0Fh)
7-1. Class attribute
ID
Access rule
Description
Value
2 Get
Max.
Instance
6
8 Get
Parameter
Class Descriptor
1
9 Get
Configuration
Assembly
Instance 0
7-2. Class common service
Service code
Description
0Eh Get_Attribute_Single
7-3. Instance attribute 5: Hold/Clear (Timeout)
ID
Access rule
Description
Value
1 Get
Parameter
Value
0: Clear setting valid (EX12
∗
-SDN1/-X2)
Switch No.9 setting valid (EX12
∗
-SDN1-X26/-X77)
1: Fault action valid
2
Get
Link Path Size
6
3
Get
Link Path
20h 64h 24h 01h 30h 68h
4 Get
Descriptor
20h
5 Get
Data
Type
C1h
6 Get
Data
Size
1
7-4. Instance attribute 6: HOLD/Clear (Delete)
ID
Access rule
Description
Value
1 Get
Parameter
Value
0: Clear setting valid (EX12
∗
-SDN1/-X2)
Switch No.9 setting valid (EX12
∗
-SDN1-X26/-X77)
1: Fault action valid
2
Get
Link Path Size
6
3
Get
Link Path
20h 64h 24h 01h 30h 69h
4 Get
Descriptor
20h
5 Get
Data
Type
C1h
6 Get
Data
Size
1
∗
1: This product does not have a function that monitors the valve power supply fuse.
The value is always 0.
7-5. Instance common service
Service code
Service name
0Eh Get_Attribute_Single
10h Set_Attribute_Single
7-6 Specific service
None.