![background image](http://html1.mh-extra.com/html/smc-networks/ex120-sdn1-x2/ex120-sdn1-x2_operation-manual_1300551025.webp)
-24-
No.EX##-OME0015-C
4-4. Solenoid status assembly iInstance
(EX12
∗
-SDN1/-X2 supports the following functions, but EX12
∗
-SDN1-X26 and -X77 do not.)
ID
Type
Description
Byte
5
Input
16 Solenoid status Points
2
The data format is shown below. (Mirror data of the output data)
Data
ID
Byte
offset
bit7
bit0
IBn+0 (OUT7)
(OUT6)
(OUT5)
(OUT4)
(OUT3)
(OUT2) (OUT1) (OUT0)
5
IBn+1 (OUT15)
(OUT14)
(OUT13)
(OUT12)
(OUT11)
(OUT10) (OUT9) (OUT8)
4-5. Solenoid output assembly instance
ID
Type
Description
Byte
35
Output
16 Solenoid output points
2
The data format is shown below.
Data
ID
Byte
offset
bit7
bit0
+0
OUT7 OUT6 OUT5 OUT4 OUT3 OUT2 OUT1 OUT0
35
+1 OUT15
OUT14
OUT13
OUT12
OUT11
OUT10
OUT9
OUT8
4-6. Instance common service
Service code
Description
0Eh Get_Attribute_Single
10h Set_Attribute_Single
4-7. Specific service
None.