Output number assignment
Combinations of the output data and the valve manifold
∗
: Output No. starts from 0, and will be assigned to the valves in order from the SI unit mounted side.
∗
: Standard wiring on the manifold is for double-solenoid valves and output number starts A side and B side in that order as shown in
the figure a.
If you mount a single-solenoid valve on the standard wiring manifold, output number for B side valve is skipped.
∗
: Custom wiring for mixed mounting single-solenoid valves and double-solenoid-valves can be specified with a Wiring Specification
Sheet. Example wiring is shown in the figure b.
∗
: Bit status “0” and ”1” on a data corresponds solenoid valve status ON and OFF (0: OFF, 1: ON), and output number starts at zero
from LSB (least significant bit).