OUT IN
5) Theoretical output
Table 3. Double acting cylinder theoretical output
(N)
Operating pressure (MPa)
Bore
size (mm)
Rod
diameter
(mm)
Operating
direction
Pressurized
area
(mm
2
)
0.3 0.5 0.7 0.9
OUT
12300
3690 6150 8610 11100
125 36
IN
11300
3390 5650 7910 10200
OUT 15400 4620
7700
10800 13900
140 36
IN 14600 4320 7200 10100 13000
OUT
20100 6030 10100 14100 18100
160 40
IN 19000 5640 9400 13200 16900
OUT
25400 7620 12700 17800 22900
180 45
IN 23900 7170 12000 16700 21500
OUT
31400 9420 15700 22000 28300
200 50
IN 29500 8850 14800 20700 26600
OUT
49100
14700 24600 34400 44200
250 60
IN 46300
13900 23200 32400 41700
OUT
70700
21200 35400 49500 63600
300 70
IN 66800
20000 33400 46800 60100
6) Kinetic energy that can be absorbed by cushion mechanism:
Table 4. Absorbable kinetic energy:
Bore size
(mm)
Effective cushion length
(mm)
Absorbable kinetic energy
(J)
125 21.0 32.3
140 21.0 44.6
160 21.0 58.8
180 22.5 78.4
200 22.5 98.0
250 28.5 147
300 28.5 265
Warning
A deceleration circuit or shock absorber may be required.
When a driven object is operated at high speed or the load is heavy, the cushioning of
the cylinder will not be sufficient to absorb the shock. Install a deceleration circuit to
reduce the speed before cushioning, or install an external shock absorber to relieve the
shock. In this case, the rigidity of the machinery should also be examined.
F
- 11 -