3
Chamfered Position and Rotation Range: Top View from Long Shaft Side
Chamfered positions shown below illustrate the conditions of actuators
when B port is pressurized.
Note)
The angle adjusting screw (adjustment bolt) is set at random within the adjustable rotating range.
Therefore, it must be re-adjusted to obtain the angle that suits your application. (Refer to page 11.)
For size 40 actuators, a parallel key will be used instead of chamfer.
Size
Recommended tightening torque for hexagon
nut to fix the adjustment bolt
20
1.5N
・
m
30,40
3.0 N
・
m