| Initial Switch Configuration
Basic Configuration
– 42 –
The switch includes an SNMP agent that supports SNMP version 1, 2c, and
3 clients. To provide management access for version 1 or 2c clients, you
must specify a community string. The switch provides a default MIB View
(i.e., an SNMPv3 construct) for the default “public” community string that
provides read access to the entire MIB tree, and a default view for the
“private” community string that provides read/write access to the entire
MIB tree. However, you may assign new views to version 1 or 2c
community strings that suit your specific security requirements (see
"Configuring SNMPv3 Views" on page 138
).
C
OMMUNITY
S
TRINGS
(
FOR
SNMP
VERSION
1
AND
2
C
CLIENTS
)
Community strings are used to control management access to SNMP
version 1 and 2c stations, as well as to authorize SNMP stations to receive
trap messages from the switch. You therefore need to assign community
strings to specified users, and set the access level.
The default strings are:
◆
public
- with read-only access. Authorized management stations are
only able to retrieve MIB objects.
◆
private
- with read/write access. Authorized management stations are
able to both retrieve and modify MIB objects.
To prevent unauthorized access to the switch from SNMP version 1 or 2c
clients, it is recommended that you change the default community strings.
To change the read-only or read/write community string, type either of the
following commands, and press <Enter>.
“snmp read community
string
”
“snmp write community
string
”
where “string” is the community access string.
>snmp read community rd
>snmp read community
Read Community : rd
>
N
OTE
:
If you do not intend to support access to SNMP version 1 and 2c
clients, we recommend that you delete both of the default community
strings. If there are no community strings, then SNMP management access
from SNMP v1 and v2c clients is disabled.
Summary of Contents for 8028L2
Page 1: ...MANAGEMENT GUIDE TigerSwitchTM 10 100 1000 28 Port Gigabit Ethernet Switch SMC8028L2 ...
Page 6: ...ABOUT THIS GUIDE 6 ...
Page 22: ...FIGURES 22 ...
Page 26: ...SECTION Getting Started 26 ...
Page 46: ...CHAPTER 2 Initial Switch Configuration Managing System Files 46 ...
Page 48: ...SECTION Web Configuration 48 ...
Page 144: ...CHAPTER 4 Configuring the Switch Configuring DHCP Relay and Option 82 Information 144 ...
Page 184: ...CHAPTER 6 Performing Basic Diagnostics Running Cable Diagnostics 184 ...
Page 238: ...CHAPTER 12 Port Commands 238 ...
Page 244: ...CHAPTER 13 Link Aggregation Commands 244 ...
Page 262: ...CHAPTER 15 RSTP Commands 262 ...
Page 272: ...CHAPTER 16 IEEE 802 1X Commands 272 ...
Page 282: ...CHAPTER 17 IGMP Commands 282 ...
Page 290: ...CHAPTER 18 LLDP Commands 290 ...
Page 296: ...CHAPTER 19 MAC Commands 296 ...
Page 306: ...CHAPTER 21 PVLAN Commands 306 ...
Page 318: ...CHAPTER 22 QoS Commands 318 ...
Page 352: ...CHAPTER 26 SNMP Commands 352 ...
Page 355: ...CHAPTER 27 HTTPS Commands 355 EXAMPLE HTTPS redirect enable HTTPS ...
Page 356: ...CHAPTER 27 HTTPS Commands 356 ...
Page 362: ...CHAPTER 29 UPnP Commands 362 ...
Page 370: ...CHAPTER 31 Firmware Commands 370 ...
Page 372: ...SECTION Appendices 372 ...
Page 386: ...GLOSSARY 386 ...
Page 391: ...INDEX 391 ...
Page 392: ...149100000079A R01 SMC8028L2 ...