Safety Instructions
2-10
06/18/04
Table2-4 Safety interlock list (Part 2)
No.
Description
Condition of unit
Indication and buzzer
How to reset
1
Overheat in Heat
Exchanger
Shuts off Switching power
supply
Error indication on display.
(ERR14)
Restart power
supply
2
Switching power
supply failure
Shuts off Switching power
supply
Error indication on display.
(ERR11)
Restart power
supply
3
Overheat in Heat
Sink
Shuts off Switching power
supply
Error indication on display.
(ERR14)
Restart power
supply
4
Low circulating
liquid level
Shuts off Switching power
supply
Error indication on display.
(ERR20)
Restart power
supply
5
Detection of
breakage of temp.
sensor
Shuts off Switching power
supply
Error indication on display.
(ERR17)
Restart power
supply
6
Excessive temp.
increase
Shuts off Switching power
supply
Error indication on display.
(ERR12)
Restart power
supply
7
Excessive temp.
decrease
Shuts off Switching power
supply
Error indication on display
(ERR13)
Restart power
supply
8
Abnormal output
(Overload)
Shuts off Switching power
supply
Error indication on display
(ERR15)
Restart power