- 42 -
(2) Symbol allocation using the setup software:
Changing pins CN1-16 to Gain changing selection (CDP).
①
Change PD04 from 00212100 to 0021210D in the I/O tab.
②
Select “Single Axis Write”.
③
Cycle the power the parametersto be enabled.
* Please allocate pins CN1-16 separately.
*
See “LECSB Operation Manual”, section 5.4.2 for details on allocation of Input signals to pins
CN1-15
– CN1-19, CN1-41, CN1-43 – CN1-45.
*
See “LECSB Operation Manual”, section 5.4.2 for details on allocation of Output signals to pins CN1-22 –
CN1-25, CN1-49.
②