background image

 

 

ASSEMBLE FRONT PANEL

 

10

 

SELECT:

 

 

1 x 1.980 Wall Sheets

 

1 x 1.520 Top Plate (Red)

 

1 x 1.520 Bottom Plate (Green)

 

1 x 1.980 Door Jamb Flashing

 

14 x 30mm Galv Clouts

 

13 x Rivets

 

IMPORTANT—IF YOU CHOOSE TO RAISE YOUR TIMBER 

BASE PLATE –READ THE FOLLOWING;

 

 

For sheds with Raised Base Plate option only (see page 6), deduct 

30mm from measurement shown between Top and Bottom Plates on 
all wall panels, so cladding protrudes 20mm below bottom plate

.

 

BOTTOM PLATE

 

1948mm

 

1948mm

 

TOP PLATE

 

960mm

 

TOP PLATE

 

DOOR OPENING

 

15mm

 

15mm

 

Plan View

 

TOP

 

PLATE

 

DOOR

 

JAMB

 

NAIL

 

x3

 

x3

 

x3

 

15mm

 

530mm

 

STEP 1:

 

 

• 

Lay out 1 x Top Plate and 1 x Bottom Plate on a flat 
surface as shown 

 

STEP 2:

 

 

• 

Using 2 x 30mm clouts, nail the Door Jamb Flashing flush with 
the top of the Top Plate at the correct  measurement as shown 
in plan view. Note the difference between left and right hand 
flashing. Pre drill holes using a 3.5mm drill bit

 

 

• 

Check the distance between the top and bottom plates then use 
a further 2 x 30mm clouts to nail the Door Jamb Flashings to 
the bottom Plate. Pre drill holes.

 

STEP 4:

 

 

• 

Place the door on the panel (In open position, approx 
20mm below top of top plate). Using two rivets, rivet the top 
and bottom hinges to the Door Jamb Flashing, ensuring 
door closes properly. 

 

 

• 

Fit remaining rivets.

 

STEP 3:

 

 

• 

Place 1 x Wall Sheet on timber plates, ensuring wall sheets fit 
underneath door jamb flashings. 

 

 

• 

Ensure that the top of the sheet is flush with the top of the 
Top Plate and that the sides of the wall sheet overhang the 
Top Plate by 

15mm

 as shown. Nail wall sheets to Top Plate 

(two clouts per pan)

 

 

• 

Nail the wall sheet to the Bottom Plate making sure that the 
Plates are the correct distance apart and that the sides of the 
wall sheets overhang the Bottom Plate by 

15mm

.

 

 

• 

Drill & rivet Door Jamb Flashings to wall sheets using four 
rivets equally spaced on each side.

 

NOTE: 

The

 

Doorway is standard at the left

-

hand end but can 

be put on the right

-

hand end..

 

NOTE: 

Door can be hinged on either side.

 

Summary of Contents for SM1515

Page 1: ...ASSEMBLY INSTRUCTIONS SM1515 BASE SIZE 1 520m x 1 520m...

Page 2: ...cess needs to be adhered to to qualify for the steel warranty of your Duratuf Smart store shed Wash all surfaces annually using a hose and soft nylon brush Within 2 km of coast wash every 3 months as...

Page 3: ...Angle 1 905m 2 Roof 1 720m 3 Door Sheet Narrow 1 940m 2 Door Sides 1 940m 2 Door Jamb 1 980m 1 Corner Door Jamb 1 980m 1 Door Brace 1 200m 2 Barge 1 720m 2 Spouting 1 555m 1 Door Top Bottom 0 945m 2 H...

Page 4: ...TS LIST PACK 2 TIMBER PACK DESCRIPTION QTY DIAGRAM Front Back Bottom Plates H4 Green 1 520 m 2 Front Back Top Plate H1 Red 1 520 m 2 Side Wall Bottom Plates H4 Green 1 520 m 2 Side Wall Top Plates H1...

Page 5: ...DE PANELS 1 LAY FOUNDATION 2 ASSEMBLE DOOR QUICK OVERVIEW Top Plate Back Side Wall Sheets Barge Flashing Spouting Roof Sheets Top Plate Side Top Plate Front Bottom Plate Front Bottom Plate Side Back W...

Page 6: ...g through from underneath During construction you may raise the bottom timber plate to allow the wall cladding to protrude 20mm below the bottom plate This will stop water flowing between the bottom p...

Page 7: ...emble door as shown ensuring narrow face of flashing is on the front as per fig 1 STEP 4 On the back of the door place door braces in posi tion as shown in fig 4 Ensure that the top and bottom ends of...

Page 8: ...with bottom of sheets flush with each other Rivet sheets together on overlaps as shown STEP 3 Nail wall sheets to the Top Plate at each end making sure that the top of the sheets are flush with the t...

Page 9: ...th bottom of sheets flush with each other Rivet the sheets together on overlaps as shown STEP 3 Nail the wall sheets to the Top Plate at each end making sure that the top of the sheets are flush with...

Page 10: ...drill bit Check the distance between the top and bottom plates then use a further 2 x 30mm clouts to nail the Door Jamb Flashings to the bottom Plate Pre drill holes STEP 4 Place the door on the panel...

Page 11: ...panels while they are screwed together Before fixing ensure that the Side Panel overlaps the Back Panel as shown Using 2 x 40mm screws screw Top Plates together in the corner Using 2 x 40mm screws 2...

Page 12: ...x rivets per join STEP 2 Position the Roof Sheets with front overhang of 130mm at each end fig 1 Using 4 x 50mm Clouts predrill and nail the Roof Sheets to the Top Plates through the ribs at each cor...

Page 13: ...REMOVE ALL DRILL FILINGS FROM ROOF WALLS AND CHANNELS THOROUGHLY FAILURE TO DO THIS WILL RESULT IN CORROSION AND COULD THEREFORE VOID THE WARRANTY FIT PADBOLT Rivet Padbolt to door and keeper onto Doo...

Page 14: ...s less than 200g m2 as published by Branz Warranty certificate being returned to manufacturer within 21 days of purchase together with proof of purchase This warranty does not cover the following Fast...

Page 15: ......

Page 16: ......

Reviews: