W
IRING
I
NSTALLATION
—STATE-SIDE GUIDE-
20
W
IRING
GUIDELINES
- S
TATE
-S
IDE
(U.S. I
NSTALLATIONS
)
T
YPICAL
I
NSTALLATION
B
REAKER
B
OX
C
LASS
A 50
AMP
, 120/240
VOLT
, GFCI
TO BE NOTED: Installation of this GFCI Circuit
Breaker, including ampere sizing and choice of qualified
electrician in accordance with the National Electrical
Code, and all applicable federal, state and local codes and
regulations in effect at the time of installation.
TO BE NOTED: The white neutral wire
from the back of the GFCI Circuit Breaker
MUST be connected to an incoming Line
Neutral. The internal mechanism of the
GFCI requires this Neutral connection for
proper GFCI function.
Ground to Spa
Ground Input
Ground Bar Attached
To Box Input & Output
Load 120V
(Black) To Spa
Load 120V
(Red) To Spa
Load Neutral
(White) To Spa
To Spa (OUTPUT)
Line (BLACK)
House Input
Line (RED)
House Input
Pig Tail (WHITE) From GFCI
Breaker Going to Neutral
Bar in Box
Load Neutral Bar
Line Neutral (WHITE) House
Input
From House (INPUT)
IMPORTANT: 6 G
AUGE
C
OPPER
W
IRE
MUST B
E
U
SED
T
EST
GFCI M
ONTHLY
AND
P
RIOR
TO
E
ACH
U
SE
.
ATTENTION ELECTRICIAN:
A
LL
S
MART
S
PA
U
NITS
MUST
BE
INSTALLED
WITH
AN
APPROVED
G.F.C.I.
IN
ACCORDANCE
WITH
ALL
APPLICABLE
CODES
. I
NSTALLATION
OF
G.F.C.I.
VARIES
AMONG
THOSE
MANUFACTURERS
.
F
OLLOW
EACH
MANUFACTURER
’
S
G
UIDELINES
TO
ENSURE
PROPER
OPERATION
AND
PROTECTION
OF
SPA
OCCUPANTS
. T
HIS
DIAGRAM
IS
A
“T
YPICAL
”
INSTALLATION
TO
BE
USED
ONLY
AS
A
REFERENCE
FOR
THE
INSTALLING
ELECTRICIAN
.