BASIC WATER CHEMISTRY CHART 

PROBLEM 
Green Algae 

 
 
 

Black Algae

 

 
 
 

Unpleasant Odor, 

Burning Eyes 

 

 

Colored Water 

 
 
 

 

Hard Water 

DESCRIPTION 

Green Water 

Green spots on surface 

Slippery surface 

 

 

Black spots on spa  surface 

 

 

 

 

Chlorine-like odor. 

Burning sensation in eyes. 

 

 

Water in newly-filled spa turns 

black, blue, or brown when 

treated with ozone 

 

 

 

 

Cloudy water 

Scaling 

 

 
 

CAUSE 

Low ozone, bromine, or chlorine levels 

Low algaecide levels 

 

 

 

Low oxidizer levels 

Low algaecide levels. 

 

 

 

Combined chlorine and/or pH out of 

balance 

 

 

Copper, iron, or manganese in water 

being oxidized by chlorine or ozone 

 

 

 

 

Excessive hardness of makeup water or 

building up of dissolved minerals in the 

water caused by continued use of spa 

chemicals.  

 
 

REMEDY 

Superchlorinate 

Brush spa; removing algae 

Vacuum spa; removing algae 

Increase oxidizer residual 

 

Superchlorinate 

Brush spa; removing algae 

Vacuum spa; removing algae 

Increase oxidizer residual 

 

Superchlorinate. 

Balance pH to 7.2-7.6 

 

 

Adjust pH to 7.2-7.6 

Run filter continuously 

Vacuum settled material 

Use sequestering agent for        

prevention 

 

Clean filter 

Filter continuously 

Adjust pH to 7.2-7.6 

Use scale inhibitor 

Dilute with makeup water 
 

O

ZONE

 U

NIT

 

Location varies with spa model. 
Refer to specifications for  
location and take note during  
installation positioning. 

O

ZONE

:   

 

 

 

Y

OUR

 

SPA

 

IS

 

EQUIPPED

 

WITH

 

OZONE

 

AS

 

THE

 

SANITIZING

 

AGENT

. T

HIS

 

UTILIZES

 

ULTRAVIOLET

 

LIGHT

 

AND

 

 

OFFERS

 

A

 “

HANDS

-

FREE

” 

ROUTINE

 

TO

 

SPA

 

WATER

 

CARE

. T

HE

 

P

MUST

 

BE

 

MAINTAINED

 

AND

 

SHOCKING

 

 

MAY

 

BE

  

NEEDED

 

AFTER

 

HEAVY

 

BATHER

 

LOADS

. W

ITH

 

THE

 

USE

 

OF

 

OZONE

THE

 

PERIODIC

 

DRAINING

 

MAY

 

 

BE

 

NEEDED

 

LESS

 

FREQUENTLY

AND

 

THE

 

BROMINE

 

ODOR

 

NO

 

LONGER

 

AN

 

ISSUE

. I

T

 

IS

 

SUGGESTED

 

THAT

       

 

16-24-

HOUR

 

CIRCULATION

 

IS

 

REQUIRED

 

TO

 

EFFECTIVELY

 

SANITIZE

 

THE

 

WATER

AND

 

A

 

CHLORINE

 

SHOCK

 

 

USED

 

PERIODICALLY

. C

ONTACT

 

YOUR

 

CHEMICAL

 

SUPPLIER

 

FOR

 

MORE

 

INFORMATION

 

 

 1. T

HERE

 

IS

 

NO

 

TEST

 

KIT

 

AVAILABLE

 

TO

 

TEST

 

OZONE

 

PRESENCE

 

IN

 

SPA

 

WATER

ALTHOUGH

 

A

 24-

HOUR

 

 

 

CIRCULATION

 

PERIOD

 

IS

 

RECOMMENDED

 

FOR

 

CLEAN

CLEAR

 

WATER

. A 

CLEAN

, “

AFTER

 

RAIN

” 

 

 

SMELL

 

WILL

 

BE

 

PRESENT

 

WHEN

 

YOU

 

OPEN

 

YOUR

 

SPA

 

COVER

 

AS

 

AN

 

INDICATOR

 

THAT

 

THE

 

OZONE

 

 

 

IS

 

DOING

 

IT

S

 

JOB

 

 

2. A 

PROPER

 

P

MUST

 

BE

 

MAINTAINED

 

AND

 

A

 

ROUTINE

 

BROMINE

 

OR

 

CHLORINE

 

SHOCK

 

IS

 

SUGGESTED

 

 

3. 

THE

 

OZONE

 

SYSTEM

 

WITH

 

YOUR

 

SPA

 

HAS

 

AN

 E

VER

L

ITE

 

INDICATOR

 

MOUNTED

 

ON

 

THE

 

CORNER

 

OF

 

THE

 

 

SPA

 

CABINET

. T

HIS

 

EMITS

 

A

 

BLUE

 

LIGHT

 

WHEN

 

THE

 

OZONE

 

UNIT

 

IS

 

FUNCTIONING

. E

VER

L

ITE

 

WILL

 

ONLY

 

 

BE

 

LIT

 

WHEN

 

UNIT

 

IS

 

IN

 

FILTRATION

 

CYCLE

. R

EFER

 

TO

 

CONTOL

 

INFORMATION

 

AND

 

ICON

 

CHART

 

FOR

      

 

FURTHER

 

INSTRUCTIONS

 

Summary of Contents for Orbit Flex Spa

Page 1: ...OWNERS INSTALLATION MANUAL PORTABLE SPA HOT TUBS REVISED 07 2009...

Page 2: ...IMMEDIATELY UPON DELIVERY REGISTER YOUR HOT TUB THIS INFORMATION IS VERY IMPORTANT TO ENSURE WARRANTY COVERAGE AND RECEIVE INFORMATION FOR POSSIBLE PRODUCT UPDATES...

Page 3: ...O WWW PDCSPAS COM REFERRING TO THE CUSTOMER CARE SEC TION OR CONTACT YOUR RETAILER DIRECTLY OWNERSHIP INFORMATION NAME ___________________________________________________ ADDRESS _____________________...

Page 4: ...CATION CONSIDERATIONS INDOORS AND OUTDOORS 14 15 GENERAL LOCATION CONSIDERATIONS 16 EQUIPMENT LOCATION 17 INSTALLING THE THERMAL COVER 18 WIRING INSTALLATION WIRING RECOMMENDATIONS 19 U S STATE SIDE G...

Page 5: ...T IS A PROFESSIONAL GRADE PRODUCT A KNOWLEDGE OF CONSTRUCTION TECHNIQUES PLUMBING AND ELECTRICAL INSTALLATION ACCORDING TO CODES ARE REQUIRED FOR PROPER INSTALLATION AND USER SATISFACTION IT IS RECOMM...

Page 6: ...6 AWG ALL FIELD INSTALLED METAL COMPONENTS SUCH AS RAILS LADDERS DRAINS OR SIMILAR HARDWARE LOCATED WITHIN 5 FEET OF THE SPA OR HOT TUB MUST BE BONDED TO THE EQUIPMENT GROUNDING BUS WITH COPPER CONDUC...

Page 7: ...IS SPA IS SIZED TO MATCH THE SPECIFIC WATER FLOW CREATED BY THE PUMP SHOULD THE NEED ARISE TO REPLACE THE SUCTION FITTING OR THE PUMP BE SURE THAT THE FLOW RATES ARE COMPATIBLE NEVER OPERATE THE SPA I...

Page 8: ...SONS USING MEDICATION SHOULD CONSULT A PHYSICIAN BEFORE USING A SPA SINCE SOME MEDICATION MAY INDUCE DROWSINESS WHILE OTHER MEDICATION MAY AFFECT HEART RATE BLOOD PRESSURE AND CIRCULATION ENTER AND LE...

Page 9: ...TORS TO COMPLYWITH SECTION 422 20 OF THE U S NATIONAL ELECTRIC CODE THE DISCONNECTING MEANS MUST BE READILY ACCESSIBLE TO THE TUB OCCUPANT BUT INSTALLED AT LEAST 5 FT 1 5 M FROM THE SPA WATER WARNING...

Page 10: ...EPARE FOR THE UNLIKELY EVENT OF RAPID SPA DRAINAGE DO NOT PLACE SPA IN DIRECT SUNLIGHT WHILE UNIT IS EMPTY OR WHEN SEALED IN SHIPPING MATERIALS EXCESSIVE HEAT BUILD MAY CAUSE DAMAGE TO SPA AND VOID WA...

Page 11: ...SIGN FOR POSTING LOCATE THE WEATHER RESISTANT SIGN ENCLOSED WITH THIS MANUAL INTENDED FOR PERMANENT POSTING IN AN AREA NEAR THE SPA VISIBLE TO ALL SPA OCCU PANTS NOTIFY THE FACTORY OR YOUR RETAILER S...

Page 12: ...CAL WALL OF THE FOOTWELL AND SERVES THE SAME FUNCTION AS THE SKIM FILTER IT WORKS IN CONJUNCTION WITH THE SKIM FILTER TO RETURN WATER TO THE SUPPORT EQUIPMENT AIR CONTROLS THESE ARE ROUND FITTINGS MOU...

Page 13: ...HEN THE SPA REACHES ITS PRESET TEMPERATURE OR THE FILTRATION CYCLE ENDS FILTER YOUR SMART SPA IS EQUIPPED WITH A SKIM FILTER THIS ASSURES OPTIMUM WATER FILTERING AND EASE OF CLEANING AT SPA SIDE REVIE...

Page 14: ...r Treatment System Ozone Ready Filter 25 sq ft Slide Valves 2 Mega Swirl Jet A 2 Large Euro Jet w Eyeball E 17 Mega ssage Jet G 1 Multi ssage Jet P 0 Ozone Jet O 1 Diverter Valves V 0 Safety Suction U...

Page 15: ...inute Water Treatment System Ozone Ready Filter 25 sq ft Slide Valves 2 Mega Swirl Jet A 1 Large Euro Jet w Eyeball E 11 Mega ssage Jet G 1 Ozone Jet O 1 Multissage Jet P 0 Diverter Valves V 0 Safety...

Page 16: ...l Jet WF N A Waterfall Control Valve N A SoundWave SE Audio N A Ozone Water Purification OZ Standard ELECTRICAL SYSTEM Pump Information Reference Number Domestic 60Hz Export 50Hz Pump 1 peak continuou...

Page 17: ...Waterfall Control Valve C N A SoundWave SE Audio N A Ozone Water Purification OZ Standard ELECTRICAL SYSTEM Pump Information Reference Number Domestic 60Hz Export 50Hz Pump 1 peak Continuous HP 1 2 0...

Page 18: ...E POSITIVE SUPPORT IS ADEQUATE CALL YOUR BUILDER 9 AREA FOR PLACEMENT OF SUPPORT EQUIPMENT WHERE ADEQUATE SPACE WILL BE NEEDED TO GAIN ACCESS TO COMPONENTS FOR MAINTENANCE AND GENERAL SERVICING 10 BE...

Page 19: ...F BARRIER PROTECTION UNDERNEATH 9 THE SPA SHOULD HAVE ACCESS TO A POWER SOURCE CAPABLE OF SUPPLYING 240 VOLTS AC POWER IT MUST BE WIRED DIRECTLY INTO A GROUNDED CIRCUIT WITH A GROUND FAULT CIRCUIT INT...

Page 20: ...ING MESH OR ROD ATTACHED TO A BOND WIRE MAKE SURE YOUR DIMENSIONS ARE CORRECT AS YOU PREPARE THE SITE FOR YOUR NEW HOT TUB CLICK ONTO THE WEB SITE OR CALL YOUR RETAILER FOR DIMENSIONS OF THE MODEL YOU...

Page 21: ...PMENT REVIEW YOUR SPA MODEL SPECIFICATION PAGE IN THIS MANUAL FOR A GUIDE OF EQUIPMENT LOCATION FOR THAT SPECIFIC SPA MODEL NOTE THE LOCATION OF THE ELECTRICAL BOX THIS WILL NEED TO BE ACCESSED TO COM...

Page 22: ...OUT OF THE REACH OF CHILDREN SPA INSTALLATION 18 REMOVE THE SPA COVER FROM THE BOX AND PLACE IT ON THE SPA PULL DOWN ONE OF THE STRAPS ON THE SPA COVER AND HOLD LATCH AGAINST THE CABINET SIDE PANEL T...

Page 23: ...RT INSTALLS AT THE POWER SOURCE NOT SUPPLIED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH ALL CODES AND REGULATIONS REFER TO TYPICAL G F C I INSTALLATION ON FOLLOWING PAGE PRIOR TO EACH USE TESTING O...

Page 24: ...for proper GFCI function Ground to Spa Ground Input Ground Bar Attached To Box Input Output Load 120V Black To Spa Load 120V Red To Spa Load Neutral White To Spa To Spa OUTPUT Line BLACK House Input L...

Page 25: ...D ELECTRICIAN ONLY AND IN ACCORDANCE WITH LOCAL REGULATIONS IDENTIFY THE CORRECT CE PLATFORM ON THE SPA UNIT IN ACCORDANCE WITH THE HOME S ELECTRICAL OUTPUT AND FOLLOW THE GUIDELINES BELOW ENSURE POWE...

Page 26: ...IF THIS OPTION IS INCLUDED ON THE SYSTEM ALLOW THE SYSTEM TO OPERATE FOR FIVE MINUTES IN THIS POSITION 10 SET THE THERMOSTAT TO THE DESIRED TEMPERATURE TO BEGIN HEATING THE SPA WATER THE INDICATOR IC...

Page 27: ...o turn light on Press a second time to turn light off A built in timer automatically turns light off unless it has been done The light indicator lights up when light is on The pump 2 indicator lights...

Page 28: ...cycle frequency This function tells the electronic control center how many times a day you would like it to run the filter duration It essentially is multiplying the filter duration by however many un...

Page 29: ...is not allowed to turn on and its icon flashes Troubleshooting Hr An internal hardware error has been detected in in xe Contact dealer or service supplier HL The system has shut the heater down becaus...

Page 30: ...TO CHLORINE ALTHOUGH IN THE FREE AND COMBINED FORM IT IS AN EFFECTIVE SANITIZING AGENT AND CAUSES NO OFFENSIVE ODOR OR EYE BURN IT IS EASIER TO MAINTAIN A BROMINE RESIDUAL THAN CHLORINE AND IT IS EFF...

Page 31: ...ust pH to 7 2 7 6 Use scale inhibitor Dilute with makeup water OZONE UNIT Location varies with spa model Refer to specifications for location and take note during installation positioning OZONE YOUR S...

Page 32: ...COVER ANYTIME THE SPA IS NOT IN USE WILL SIGNIFICANTLY REDUCE YOUR OPERATING COSTS HEAT UP TIME AND MAINTENANCE REQUIREMENTS TO PROLONG THE LIFE OF THE COVER HANDLE IT WITH CARE AND CLEAN IT REGULARLY...

Page 33: ...SPAS DEVELOP A LEAK CAUSED BY SHIPPING VIBRATION OVER THE YEARS YOUR SPA IS SUBJECTED TO MANY HOT COLD CYCLES AND THE HIGH PRESSURE GENERATED BY THE POWERFUL JET PUMP WHICH TOGETHER STRESSES THE PIPES...

Page 34: ...NOT BE USED FOR A PERIOD OF TIME PERFORM THE FOLLOWING WINTERIZING PROCEDURES 1 TURN HEAT ALL THE WAY DOWN AND TURN OFF AT THE BREAKER 2 DRAIN SPA OF ALL WATER 3 REMOVE ANY REMAINING WATER WITH SPONG...

Page 35: ...A DUAL SPEED PUMP 3 INADEQUATE JET ACTION MAKE SURE JETS ARE TURNED ON MAKE SURE AIR CONTROLS ARE OPEN CHECK FOR RESTRICTIONS BLOCKAGES IN JETS AND OR MAIN SKIMMER AND PUMP CHECK WATER LEVEL PUSH PUMP...

Page 36: ..._______________________________________________ _______________________________________________________________ _______________________________________________________________ ________________________...

Reviews: