ELECTRICAL
SPECIFICATIONS
:
Input rating: 230 VAC nominal
(Single phase input Only; multi-phase not supported)
32 A absolute maximum, 50 Hz nominal.
Correct wiring of the electrical service
box, RCD protection device, and pack
terminal block is essential!
Contact qualified, licensed electrician.
In.XE CE 230 VAC
Single phase ONLY
I
N
.XE P
LATFORM
C
ONTROL
C
ENTER
1 x 230 VAC (1 x 32A) single phase,
or
1 x 230 VAC (2 x 16A) dual phase **
W
IRING
I
NSTALLATION
—EXPORT GUIDELINES
IN
.
XE
A
LL
INSTALLATIONS
AND
CONNECTIONS
ARE
TO
BE
PERFORMED
BY
A
QUALIFIED
,
LICENSED
ELECTRICIAN
ONLY
AND
IN
ACCORDANCE
WITH
LOCAL
REGULATIONS
. I
DENTIFY
THE
CORRECT
CE
PLATFORM
ON
THE
SPA
UNIT
,
IN
ACCORDANCE
WITH
THE
HOME
’
S
ELECTRICAL
OUTPUT
,
AND
FOLLOW
THE
GUIDELINES
BELOW
. E
NSURE
POWER
IS
TURNED
OFF
PRIOR
TO
MAKING
ANY
ELECTRICAL
CONNECTIONS
.
This product must always be connected to a circuit protected by a residual-current device (RCD) having
a rated operating residual-current not exceeding 30 mA. Proper wiring of the electrical service box, RCD
and in.xe.ce terminal block is essential! Check your electrical code for local regulations. Only copper
wire should be used, never aluminum.
!
Warning!
INSTALLATION GUIDELINES for IN.XE CE
** Contact your retailer for electrical specifications and connection instructions when this option becomes available.