background image

G

ENERAL

 L

OCATION

 C

ONSIDERATIONS

 

 

R

EVIEW

 

OUTDOOR

 

INSTALLATIONS

 

AND

 

INDOOR

 

INSTALLATIONS

 

PRIOR

 

TO

 

CHOOSING

 

YOUR

 

SPA

            

LOCATION

. Y

OUR

 

SPA

 

SHOULD

 

BE

 

PLACED

 

ON

 

A

 

LEVEL

 

CONCRETE

 

PAD

 

OR

 

ON

 

A

 

DECK

 

DESIGNED

 

TO

 

SUPPORT

 6000 

LBS

 (2722 

KG

.) 

OR

 

ON

 

PATIO

 

BLOCKS

 

ON

 

THE

 

GROUND

. D

O

 

NOT

 

PLACE

 

THE

 

SPA

 

ON

 

A

 

DIRT

 

SURFACE

 

OR

 

DIRECTLY

 

ON

 

THE

 

GROUND

. O

NCE

 

YOU

 

HAVE

 

A

 

LOCATION

 

SELECTED

THERE

 

ARE

 

SEVERAL

 

ISSUES

 

YOU

 

SHOULD

 

CONSIDER

 

IN

 

PREPARING

 

THE

 

SITE

 

FOR

 

THE

 

HOT

 

TUB

 

INSTALLATION

 
 

FLAT

LEVEL

 

SURFACE

 

THAT

 

IS

 

STRONG

 

ENOUGH

 

TO

 

SUPPORT

 

YOUR

 

SPA

 

IS

 

REQUIRED

. O

NCE

 

YOUR

 

SPA

 

IS

 

FILLED

IT

 

HAS

 

CONSIDERABLE

 

WEIGHT

. M

AKE

 

CERTAIN

 

THE

 

LOCATION

 

YOU

 

CHOOSE

 

CAN

 

SUPPORT

 

A

 

MINIMUM

 

OF

 100 

LBS

 (45.4 

KG

PER

 

SQUARE

 

FOOT

 

LOAD

PER

 

RECOMMENDED

 

GUIDELINES

. S

TRUCTURAL

 

DAMAGE

 

TO

 

THE

 

SPA

  

RESULTING

 

FROM

 

THE

 

INCORRECT

 

INSTALLATION

 

OF

 

PLACEMENT

 

ON

 

INADEQUATE

 

FOUNDATION

 

IS

 

NOT

 

COV-

ERED

 

IN

 

THE

 

SPA

S

 

LIMITED

 

WARRANTY

 
 

M

OST

 

UNITS

 

ARE

 

INSTALLED

 

OUTSIDE

ON

 

GROUND

 

LEVEL

ON

 

EITHER

 

A

 

CONCRETE

 

PAD

 

OR

 

A

 

WOODEN

 

DECK

. I

F

 

THE

 

SPA

 

IS

 

NOT

 

ON

 

GROUND

 

LEVEL

HAVE

 

A

 

BUILDER

 

DETERMINE

 

IF

 

THE

 

SUPPORT

 

IS

 

ADEQUATE

. I

F

 

THE

 

UNIT

 

IS

 

PLACED

 

DIRECTLY

 

ON

 

THE

 

GROUND

YOU

 

WILL

 

WANT

 

TO

 

REMOVE

 

THE

 

GRASSY

 

LEVEL

AND

 

PLACE

 

A

 

LAYER

 

OF

 

GRAVEL

 

ON

 

THE

 

SOIL

. T

HE

 

BEST

 

WAY

 

TO

 

LEVEL

 

THE

 

GRAVEL

 

MAY

 

BE

 

WITH

 

THE

 

STRAIGHT

 

EDGE

 

OF

 

A

 

PIECE

 

OF

 

SOLID

 

LUMBER

 

 

TO

 

ACHIEVE

 

A

 

LEVEL

 

SURFACE

. P

AVERS

 

PLACED

 

IN

 

A

 

SAND

 

BASE

 

IS

 

ALSO

 

A

 

RATHER

 

QUICK

 

AND

 

CONVENIENT

 

WAY

 

TO

 

PREPARE

 

THE

 

LOCATION

 

SITE

. N

OTE

 

THAT

 

PAVERS

STEPPING

 

STONES

ETC

STILL

 

HAVE

 

A

 

TENDENCY

 

TO

 

SETTLE

 

AND

 

MAY

 

BECOME

   

UNLEVEL

 

AT

 

SOME

 

POINT

. A 

REINFORCED

 

CONCRETE

 

SLAB

 

SHOULD

 

BE

 

AT

 

LEAST

 

FOUR

 

INCHES

 

THICK

 

WITH

 

THE

 

REINFORCING

 

MESH

 

OR

 

ROD

 

ATTACHED

 

TO

 

A

 

BOND

 

WIRE

 
 

M

AKE

 

SURE

 

YOUR

 

DIMENSIONS

 

ARE

 

CORRECT

 

AS

 

YOU

 

PREPARE

 

THE

 

SITE

 

FOR

 

YOUR

 

NEW

 

HOT

 

TUB

. C

LICK

 

ONTO

 

THE

 

WEB

 

SITE

 

OR

 

CALL

 

YOUR

 

RETAILER

 

FOR

 

DIMENSIONS

 

OF

 

THE

 

MODEL

 

YOU

 

HAVE

 

CHOSEN

. A

LLOW

 

A

   

PERIMETER

 

OF

 

THE

 

CHOSEN

 

GROUND

 

SURFACE

 

TO

 

EXTEND

 

BEYOND

 

THE

 

SPA

 

ITSELF

 

TO

 

PROVIDE

 

A

 

CLEAN

 

AREA

 

FOR

 

USERS

 

TO

 

GET

 

IN

 

AND

 

OUT

 

OF

 

THE

 

SPA

 
 

T

HE

 

SPA

 

LOCATION

 

AND

 

THE

 

SPA

 

ITSELF

 

MUST

 

BE

 

LEVEL

 

BEFORE

 

FILLING

 

WITH

 

WATER

 
 

S

HOULD

 

YOUR

 

SPA

 

SITE

 

BE

 

A

 

WOODEN

 

DECK

THIS

 

PROVIDES

 

A

 

CLEAN

 

AREA

 

WITH

 

WEATHER

 

AND

 

ROT

 

RESISTANT

 

QUALITIES

IF

 

A

 

PRESSURE

-

TREATED

 

TYPE

 

LUMBER

 

IS

 

USED

. C

ONSIDER

 

THE

 

LOAD

 

REQUIREMENTS

 

AND

 

CONSULT

 

A

 

BUILDER

 

TO

 

DETERMINE

 

IF

 

YOUR

 

DECK

 

IS

 

OF

 

ADEQUATE

 

STRENGTH

 
 

I

F

 

INSTALLING

 

YOUR

 

HOT

 

TUB

 

BELOW

 

GRADE

CONSIDER

 

ADEQUATE

 

DRAINAGE

 

FOR

 

RUN

-

OFF

 

AND

 

THE

 

UNLIKELY

 

EVENT

 

OF

 

RAPID

 

SPA

 

DRAINAGE

 
 

A

LLOW

 

ADEQUATE

 

SPACE

 

TO

 

ACCESS

 

THE

 

EQUIPMENT

 

BEHIND

 

THE

 

FOUR

 

ACCESS

 

PANELS

 

ON

 

THE

 

HOT

 

TUB

 

CABINET

. R

EVIEW

 

THE

 

PAGES

 

IN

 

THIS

 

MANUAL

 

REFERENCING

 

SPA

 

MODEL

 

SPECIFICATIONS

 

FOR

 

THE

 

LOCATION

 

OF

 

THE

 

SUPPORT

 

EQUIPMENT

 

FOR

 

THE

 

MODEL

 

YOU

 

HAVE

 

CHOSEN

 
 

L

EAVE

 

AMPLE

 

ACCESS

 

TO

 

THE

 GFCI 

CIRCUIT

 

BREAKER

 

FOR

 

TESTING

ETC

 
 

QUICK

 

DISCONNECT

 (

MANUAL

 

DISCONNECT

IS

 

TO

 

BE

 

INSTALLED

 

BETWEEN

 5 - 15 

FT

 (1.5-4.6 

M

OF

 

THE

 

SPA

 

AND

 

WITHIN

 

THE

 

LINE

 

OF

 

SIGHT

 

FROM

 

THE

 

HOT

 

TUB

. C

ONSIDER

 

WHERE

 

THIS

 

CAN

 

BE

 

LOCATED

 

WHEN

   

SELECT-

ING

 

AND

 

PREPARING

 

THE

 

SPA

 

SITE

. A

LL

 

WIRING

 

MUST

 

COMPLY

 

WITH

 

THE

 U.S. N

ATIONAL

 E

LECTRIC

 C

ODE

 
 

CABINET

 

SIDE

 

DRAIN

 

HAS

 

BEEN

 

INSTALLED

 

ON

 

THE

 

BOTTOM

 

PORTION

 

OF

 

A

 

CABINET

 

SIDEWALL

 

FOR

 

EASY

 

DRAINING

. L

OCATE

 

THIS

 

DRAIN

 

AND

 

LEAVE

 

AMPLE

 

ACCESS

. Y

OUR

 

SPA

 

MAY

 

HAVE

 

BEEN

 

CHOSEN

 

WITH

 

THE

 

A

DVANTAGE

P

ACK

 

DESIGN

WITH

 

THIS

 

FEATURE

ALL

 

THE

 

EQUIPMENT

 

IS

 

LOCATED

 

BENEATH

 

AN

 

END

 

CABINET

.   

A

LLOW

  

EASY

 

ACCESS

 

TO

 

ALL

 

COMPONENTS

. T

HIS

 

DESIGN

 

ALSO

 

FEATURES

 

A

 

SIDE

 

DRAIN

 

FOR

 

EMPTYING

 

S

PA

 I

NSTALLATION

 

16 

Summary of Contents for Orbit Flex Spa

Page 1: ...OWNERS INSTALLATION MANUAL PORTABLE SPA HOT TUBS REVISED 07 2009...

Page 2: ...IMMEDIATELY UPON DELIVERY REGISTER YOUR HOT TUB THIS INFORMATION IS VERY IMPORTANT TO ENSURE WARRANTY COVERAGE AND RECEIVE INFORMATION FOR POSSIBLE PRODUCT UPDATES...

Page 3: ...O WWW PDCSPAS COM REFERRING TO THE CUSTOMER CARE SEC TION OR CONTACT YOUR RETAILER DIRECTLY OWNERSHIP INFORMATION NAME ___________________________________________________ ADDRESS _____________________...

Page 4: ...CATION CONSIDERATIONS INDOORS AND OUTDOORS 14 15 GENERAL LOCATION CONSIDERATIONS 16 EQUIPMENT LOCATION 17 INSTALLING THE THERMAL COVER 18 WIRING INSTALLATION WIRING RECOMMENDATIONS 19 U S STATE SIDE G...

Page 5: ...T IS A PROFESSIONAL GRADE PRODUCT A KNOWLEDGE OF CONSTRUCTION TECHNIQUES PLUMBING AND ELECTRICAL INSTALLATION ACCORDING TO CODES ARE REQUIRED FOR PROPER INSTALLATION AND USER SATISFACTION IT IS RECOMM...

Page 6: ...6 AWG ALL FIELD INSTALLED METAL COMPONENTS SUCH AS RAILS LADDERS DRAINS OR SIMILAR HARDWARE LOCATED WITHIN 5 FEET OF THE SPA OR HOT TUB MUST BE BONDED TO THE EQUIPMENT GROUNDING BUS WITH COPPER CONDUC...

Page 7: ...IS SPA IS SIZED TO MATCH THE SPECIFIC WATER FLOW CREATED BY THE PUMP SHOULD THE NEED ARISE TO REPLACE THE SUCTION FITTING OR THE PUMP BE SURE THAT THE FLOW RATES ARE COMPATIBLE NEVER OPERATE THE SPA I...

Page 8: ...SONS USING MEDICATION SHOULD CONSULT A PHYSICIAN BEFORE USING A SPA SINCE SOME MEDICATION MAY INDUCE DROWSINESS WHILE OTHER MEDICATION MAY AFFECT HEART RATE BLOOD PRESSURE AND CIRCULATION ENTER AND LE...

Page 9: ...TORS TO COMPLYWITH SECTION 422 20 OF THE U S NATIONAL ELECTRIC CODE THE DISCONNECTING MEANS MUST BE READILY ACCESSIBLE TO THE TUB OCCUPANT BUT INSTALLED AT LEAST 5 FT 1 5 M FROM THE SPA WATER WARNING...

Page 10: ...EPARE FOR THE UNLIKELY EVENT OF RAPID SPA DRAINAGE DO NOT PLACE SPA IN DIRECT SUNLIGHT WHILE UNIT IS EMPTY OR WHEN SEALED IN SHIPPING MATERIALS EXCESSIVE HEAT BUILD MAY CAUSE DAMAGE TO SPA AND VOID WA...

Page 11: ...SIGN FOR POSTING LOCATE THE WEATHER RESISTANT SIGN ENCLOSED WITH THIS MANUAL INTENDED FOR PERMANENT POSTING IN AN AREA NEAR THE SPA VISIBLE TO ALL SPA OCCU PANTS NOTIFY THE FACTORY OR YOUR RETAILER S...

Page 12: ...CAL WALL OF THE FOOTWELL AND SERVES THE SAME FUNCTION AS THE SKIM FILTER IT WORKS IN CONJUNCTION WITH THE SKIM FILTER TO RETURN WATER TO THE SUPPORT EQUIPMENT AIR CONTROLS THESE ARE ROUND FITTINGS MOU...

Page 13: ...HEN THE SPA REACHES ITS PRESET TEMPERATURE OR THE FILTRATION CYCLE ENDS FILTER YOUR SMART SPA IS EQUIPPED WITH A SKIM FILTER THIS ASSURES OPTIMUM WATER FILTERING AND EASE OF CLEANING AT SPA SIDE REVIE...

Page 14: ...r Treatment System Ozone Ready Filter 25 sq ft Slide Valves 2 Mega Swirl Jet A 2 Large Euro Jet w Eyeball E 17 Mega ssage Jet G 1 Multi ssage Jet P 0 Ozone Jet O 1 Diverter Valves V 0 Safety Suction U...

Page 15: ...inute Water Treatment System Ozone Ready Filter 25 sq ft Slide Valves 2 Mega Swirl Jet A 1 Large Euro Jet w Eyeball E 11 Mega ssage Jet G 1 Ozone Jet O 1 Multissage Jet P 0 Diverter Valves V 0 Safety...

Page 16: ...l Jet WF N A Waterfall Control Valve N A SoundWave SE Audio N A Ozone Water Purification OZ Standard ELECTRICAL SYSTEM Pump Information Reference Number Domestic 60Hz Export 50Hz Pump 1 peak continuou...

Page 17: ...Waterfall Control Valve C N A SoundWave SE Audio N A Ozone Water Purification OZ Standard ELECTRICAL SYSTEM Pump Information Reference Number Domestic 60Hz Export 50Hz Pump 1 peak Continuous HP 1 2 0...

Page 18: ...E POSITIVE SUPPORT IS ADEQUATE CALL YOUR BUILDER 9 AREA FOR PLACEMENT OF SUPPORT EQUIPMENT WHERE ADEQUATE SPACE WILL BE NEEDED TO GAIN ACCESS TO COMPONENTS FOR MAINTENANCE AND GENERAL SERVICING 10 BE...

Page 19: ...F BARRIER PROTECTION UNDERNEATH 9 THE SPA SHOULD HAVE ACCESS TO A POWER SOURCE CAPABLE OF SUPPLYING 240 VOLTS AC POWER IT MUST BE WIRED DIRECTLY INTO A GROUNDED CIRCUIT WITH A GROUND FAULT CIRCUIT INT...

Page 20: ...ING MESH OR ROD ATTACHED TO A BOND WIRE MAKE SURE YOUR DIMENSIONS ARE CORRECT AS YOU PREPARE THE SITE FOR YOUR NEW HOT TUB CLICK ONTO THE WEB SITE OR CALL YOUR RETAILER FOR DIMENSIONS OF THE MODEL YOU...

Page 21: ...PMENT REVIEW YOUR SPA MODEL SPECIFICATION PAGE IN THIS MANUAL FOR A GUIDE OF EQUIPMENT LOCATION FOR THAT SPECIFIC SPA MODEL NOTE THE LOCATION OF THE ELECTRICAL BOX THIS WILL NEED TO BE ACCESSED TO COM...

Page 22: ...OUT OF THE REACH OF CHILDREN SPA INSTALLATION 18 REMOVE THE SPA COVER FROM THE BOX AND PLACE IT ON THE SPA PULL DOWN ONE OF THE STRAPS ON THE SPA COVER AND HOLD LATCH AGAINST THE CABINET SIDE PANEL T...

Page 23: ...RT INSTALLS AT THE POWER SOURCE NOT SUPPLIED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH ALL CODES AND REGULATIONS REFER TO TYPICAL G F C I INSTALLATION ON FOLLOWING PAGE PRIOR TO EACH USE TESTING O...

Page 24: ...for proper GFCI function Ground to Spa Ground Input Ground Bar Attached To Box Input Output Load 120V Black To Spa Load 120V Red To Spa Load Neutral White To Spa To Spa OUTPUT Line BLACK House Input L...

Page 25: ...D ELECTRICIAN ONLY AND IN ACCORDANCE WITH LOCAL REGULATIONS IDENTIFY THE CORRECT CE PLATFORM ON THE SPA UNIT IN ACCORDANCE WITH THE HOME S ELECTRICAL OUTPUT AND FOLLOW THE GUIDELINES BELOW ENSURE POWE...

Page 26: ...IF THIS OPTION IS INCLUDED ON THE SYSTEM ALLOW THE SYSTEM TO OPERATE FOR FIVE MINUTES IN THIS POSITION 10 SET THE THERMOSTAT TO THE DESIRED TEMPERATURE TO BEGIN HEATING THE SPA WATER THE INDICATOR IC...

Page 27: ...o turn light on Press a second time to turn light off A built in timer automatically turns light off unless it has been done The light indicator lights up when light is on The pump 2 indicator lights...

Page 28: ...cycle frequency This function tells the electronic control center how many times a day you would like it to run the filter duration It essentially is multiplying the filter duration by however many un...

Page 29: ...is not allowed to turn on and its icon flashes Troubleshooting Hr An internal hardware error has been detected in in xe Contact dealer or service supplier HL The system has shut the heater down becaus...

Page 30: ...TO CHLORINE ALTHOUGH IN THE FREE AND COMBINED FORM IT IS AN EFFECTIVE SANITIZING AGENT AND CAUSES NO OFFENSIVE ODOR OR EYE BURN IT IS EASIER TO MAINTAIN A BROMINE RESIDUAL THAN CHLORINE AND IT IS EFF...

Page 31: ...ust pH to 7 2 7 6 Use scale inhibitor Dilute with makeup water OZONE UNIT Location varies with spa model Refer to specifications for location and take note during installation positioning OZONE YOUR S...

Page 32: ...COVER ANYTIME THE SPA IS NOT IN USE WILL SIGNIFICANTLY REDUCE YOUR OPERATING COSTS HEAT UP TIME AND MAINTENANCE REQUIREMENTS TO PROLONG THE LIFE OF THE COVER HANDLE IT WITH CARE AND CLEAN IT REGULARLY...

Page 33: ...SPAS DEVELOP A LEAK CAUSED BY SHIPPING VIBRATION OVER THE YEARS YOUR SPA IS SUBJECTED TO MANY HOT COLD CYCLES AND THE HIGH PRESSURE GENERATED BY THE POWERFUL JET PUMP WHICH TOGETHER STRESSES THE PIPES...

Page 34: ...NOT BE USED FOR A PERIOD OF TIME PERFORM THE FOLLOWING WINTERIZING PROCEDURES 1 TURN HEAT ALL THE WAY DOWN AND TURN OFF AT THE BREAKER 2 DRAIN SPA OF ALL WATER 3 REMOVE ANY REMAINING WATER WITH SPONG...

Page 35: ...A DUAL SPEED PUMP 3 INADEQUATE JET ACTION MAKE SURE JETS ARE TURNED ON MAKE SURE AIR CONTROLS ARE OPEN CHECK FOR RESTRICTIONS BLOCKAGES IN JETS AND OR MAIN SKIMMER AND PUMP CHECK WATER LEVEL PUSH PUMP...

Page 36: ..._______________________________________________ _______________________________________________________________ _______________________________________________________________ ________________________...

Reviews: