SmartPlug 1Led User Manual Download Page 8

 

Afterwards,  the  Smartstart  mode  will  be  auto  running  with  512  second  interval  until  device  is 
included successfully. 

Security Network 

The device supports the security function with and S2 + SmartStart encrypted communication. The 
device will auto switch to the security mode when the device included with a security controller. In 
the security mode, the follow commands must use security or security_2 command class wrapped to 
communicate, otherwise the device will not response any commands.

 

Security Keys 

This device supports security levels are listed in below table: 

Security Levels 

Support (Yes/No) 

SECURITY_KEY_S0 

Yes 

SECURITY_KEY_S2_UNAUTHENTICATED  Yes 
SECURITY_KEY_S2_AUTHENTICATED 

Yes 

SECURITY_KEY_S2_ACCESS 

No 

All Supports Command Class in Each NIF Lists 

Command Class 

Version 

Not 

Included 

Non-secure 

Included 

S0 Included 

S2 Included 

Non-Secure 

Secure 

Non-Secure 

Secure 

COMMAND_CLASS_ZWAVEPLUS_INFO 

 

 

 

 

 

 

COMMAND_CLASS_SECURITY 

 

 

 

 

 

 

COMMAND_CLASS_SECURITY_2 

 

 

 

 

 

 

COMMAND_CLASS_TRANSPORT_SERVICE 

 

 

 

 

 

 

COMMAND_CLASS_VERSION 

 

 

 

 

 

 

COMMAND_CLASS_POWERLEVEL 

 

 

 

 

 

 

COMMAND_CLASS_ASSOCIATION 

 

 

 

 

 

 

COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION 

 

 

 

 

 

 

COMMAND_CLASS_ASSOCIATION_GRP_INFO 

 

 

 

 

 

 

COMMAND_CLASS_MANUFACTURER_SPECIFIC 

 

 

 

 

 

 

COMMAND_CLASS_DEVICE_RESET_LOCALLY 

 

 

 

 

 

 

COMMAND_CLASS_SWITCH_BINARY 

 

 

 

 

 

 

COMMAND_CLASS_NOTIFICATION 

● 

● 

 

● 

 

● 

COMMAND_CLASS_METER 

● 

● 

 

● 

 

● 

COMMAND_CLASS_INDICATOR 

 

 

 

 

 

 

COMMAND_CLASS_CONFIGURATION 

 

 

 

 

 

 

Summary of Contents for 1Led

Page 1: ...tPlug 1Led User Manual Z Wave 700s S2 Version Version Written By Date Change List 1 0 Yongqi 20201022 Initial 1 1 Yongqi 20210116 Fixed Some Error Descriptions 1 2 Yongqi 20210304 Add Note for OTA Led...

Page 2: ...f Blue led will blink with 1s interval until inclusion successful Remove 1 Power up the device 2 Set Z Wave Controller into exclusion mode 3 Press and hold the button for 5s until Blue led lights is o...

Page 3: ...CLASS_INDICATOR COMMAND_CLASS_DEVICE_RESET_LOCALLY SWITCH_BINARY_REPORT NOTIFICATION_REPORT METER_REPORT INDICATOR_REPORT DEVICE_RESET_LOCALLY_NOTIFICATION 2 Control COMMAND_CLASS_BASIC BASIC_SET Devi...

Page 4: ...ive energy value 2 Execute the factory reset operation to reset the cumulative energy value The cumulative energy will not be reset if SmartPlug remove from Z Wave Network by exclusion operation Over...

Page 5: ...ize Byte Available Settings Default value 1 1 0 1 1 2 Button Switch Function Disable Setting this configuration as 0 will be disabling to turn on and off the relay by pressed button Parameter Number S...

Page 6: ...nt setting This configuration sets the maximum output current that the device can provide When the current consumed by the load is greater than the setting value the device will automatically cut off...

Page 7: ...itch Set 0 3 Basic Set 1 99 maps to Binary Switch Set 255 4 Basic Get Report maps to Binary Switch Get Report SmartStart SmartStart enabled products can be added into a Z Wave network by scanning the...

Page 8: ...Support Yes No SECURITY_KEY_S0 Yes SECURITY_KEY_S2_UNAUTHENTICATED Yes SECURITY_KEY_S2_AUTHENTICATED Yes SECURITY_KEY_S2_ACCESS No All Supports Command Class in Each NIF Lists Command Class Version N...

Page 9: ...with S0 level COMMAND_CLASS_MANUFACTURER_SPECIFIC is supported non securely And when device is included with S2 level COMMAND_CLASS_MANUFACTURER_SPECIFIC is supported securely only Notice 2 Indicates...

Page 10: ...Z Wave Network Send NIF Blink with 1s Interval Add to Z Wave Network Blink with 300ms Interval OTA is Running Note 1 The LED State is Not Changed when Led Is Busy On or Blink Such as Relay on Over Cu...

Reviews: