SmartPlug 1Led User Manual Download Page 2

 

SmartPlug is a universal, Z-Wave™ Plus compatible and relay switch in the form of a socket adapter. 
The  device  may  be  used  to  operate  any  device  up  to  3000w  power  output.  The  device  features 
voltage, current, active power and power consumption measuring. 
 
This product can be included and operated in any Z-Wave™ network with other Z-Wave™ certified 
devices from other manufacturers and/or other applications. All non-battery operated nodes within 
the network will act as repeaters regardless of vendor to increase reliability of the network. 
 

This device must be used in conjunction with a Security Enabled Z-Wave Controller in order to fully 
utilize all implemented functions

 

Z-Wave™ Network Inclusion/Exclusion/Reset 

There is one button on the side of the device, it can be executed inclusion, exclusion and reset from 
Z-Wave™ network. 

Add¹ 

1

 

Power up the device. 

2

 

Set Z-Wave™ Controller into inclusion mode 

3

 

Press and hold the button for 5s until  Blue 
led  lights  is  on,  then  release  the  button 
before led turn off. 

Blue led will blink with 1s 
interval  until  inclusion 
successful. 

Remove 

1

 

Power up the device. 

2

 

Set Z-Wave™ Controller into exclusion mode 

3

 

Press and hold the button for 5s until Blue 
led  lights  is  on,  then  release  the  button 
before led turn off. 

Blue  led  will  blink  with 
0.5s 

interval 

until 

exclusion successful. 

Factory Reset² 

1

 

Power up the device. 

2

 

Press and hold the button for 10s until leds 
light on, then release the button before led 
turn off. 

 

Product Test Mode 

1

 

Press and hold the button. 

2

 

Power  on  the  device,  device  will  enter 
factory  product  test  mode  with Blue  light 
flash. 

 

Send NIF³ 

Press and hold the button for 5s until Blue 
led  lights  is  on,  then  release  the  button 
before led turn off. 

 

Notice 1: 

When device enters into inclusion mode, the device all functionality will be useless. The 

inclusion mode will be timeout after 30s, user can implement step 3 to terminate inclusion mode. 

Notice 2: 

Factory Reset will clear the device all Z-Wave™ Network data (include home id, node id, 

etc…) saved in memory, and restore all configuration parameters to factory default. Please use this 
procedure only when the network primary controller is missing or otherwise inoperable. 

Notice 3: 

NIF – Node Information Frame 

Summary of Contents for 1Led

Page 1: ...tPlug 1Led User Manual Z Wave 700s S2 Version Version Written By Date Change List 1 0 Yongqi 20201022 Initial 1 1 Yongqi 20210116 Fixed Some Error Descriptions 1 2 Yongqi 20210304 Add Note for OTA Led...

Page 2: ...f Blue led will blink with 1s interval until inclusion successful Remove 1 Power up the device 2 Set Z Wave Controller into exclusion mode 3 Press and hold the button for 5s until Blue led lights is o...

Page 3: ...CLASS_INDICATOR COMMAND_CLASS_DEVICE_RESET_LOCALLY SWITCH_BINARY_REPORT NOTIFICATION_REPORT METER_REPORT INDICATOR_REPORT DEVICE_RESET_LOCALLY_NOTIFICATION 2 Control COMMAND_CLASS_BASIC BASIC_SET Devi...

Page 4: ...ive energy value 2 Execute the factory reset operation to reset the cumulative energy value The cumulative energy will not be reset if SmartPlug remove from Z Wave Network by exclusion operation Over...

Page 5: ...ize Byte Available Settings Default value 1 1 0 1 1 2 Button Switch Function Disable Setting this configuration as 0 will be disabling to turn on and off the relay by pressed button Parameter Number S...

Page 6: ...nt setting This configuration sets the maximum output current that the device can provide When the current consumed by the load is greater than the setting value the device will automatically cut off...

Page 7: ...itch Set 0 3 Basic Set 1 99 maps to Binary Switch Set 255 4 Basic Get Report maps to Binary Switch Get Report SmartStart SmartStart enabled products can be added into a Z Wave network by scanning the...

Page 8: ...Support Yes No SECURITY_KEY_S0 Yes SECURITY_KEY_S2_UNAUTHENTICATED Yes SECURITY_KEY_S2_AUTHENTICATED Yes SECURITY_KEY_S2_ACCESS No All Supports Command Class in Each NIF Lists Command Class Version N...

Page 9: ...with S0 level COMMAND_CLASS_MANUFACTURER_SPECIFIC is supported non securely And when device is included with S2 level COMMAND_CLASS_MANUFACTURER_SPECIFIC is supported securely only Notice 2 Indicates...

Page 10: ...Z Wave Network Send NIF Blink with 1s Interval Add to Z Wave Network Blink with 300ms Interval OTA is Running Note 1 The LED State is Not Changed when Led Is Busy On or Blink Such as Relay on Over Cu...