Timer
The device also provides the function of timing, and users can turn off the outlet by opening this
function and setting the time cycle, the setting method of which is shown in "
Configuration: No.4
and Configuration No 11
".
Command Class Configuration
The device supports the controller to configure parameters of the device through Configuration
Command Class, and the device has 11 parameters available for users to set according to their
different needs:
1)
Relay On/Off state Saved Disable
Sets this configuration to ‘1’, the device will save the current relay state, and after the device
is powered down and restarted, it will automatically recover to the relay state before
power-down.Set to '0',device won't remember the previous state,default to be ON.
Parameter Number Size (Byte)
Available Settings
Default value
1
1
0, 1
1
2)
Button Switch Function Disable
Setting this configuration as ‘0’ will be disabling to turn on and off the relay by pressed
button.
Parameter Number Size (Byte)
Available Settings
Default value
2
1
0, 1
1
3)
LED indication Disable
Setting this configuration as ‘0’ will disable led light on when turn on the device. This setting
is invalid during device power-up.
Parameter Number Size (Byte)
Available Settings
Default value
3
1
0, 1
1
4)
Countdown Timer Enable
Setting this configuration as ‘1’ will start the timing function of the plug, and the length of
time is determined by the setting of “
Configuration: No.7
”.
This function can only provide the time to turn off device function when the device is open.
Parameter Number Size (Byte)
Available Settings
Default value
4
1
0, 1
0
5)
Meter Enable
This configuration sets the meter Monitoring function enabled or disabled.
‘0’ – Disable meter measuring Function.
‘1’ – Enable meter measuring Function.