SmartPlug 1Led User Manual Download Page 7

 

Parameter Number  Size (Byte) 

Available Settings 

Default value 

10 

0 ~ 1000 

50 

 

11)

 

Interval of meter reporting setting 
This configuration sets the interval of reporting electric quantity detection result. This 
parameter is only valid when Parameter 6 is set as ‘1’. Unit: Second. 
Parameter Number  Size (Byte) 

Available Settings 

Default value 

11 

0 ~ 30000 

300 

 

● 

To  Simulate  Over  Current  Protection  Function,  First  User  Must  Turn  on  SmartPlug  And  Then 
Write 1 Byte Data 0xFF(255) to 

Parameter Number 99

. SmartPlug will Be Turned Off And Report 

Alarm  Messages  to  Hubs.  Meantime  Blue  Led  Will  Blink  with  1s  Interval.  This  must  set 

Configuration No. 5

” to ‘1’. 

Command Class Basic 

The Basic Command Class is mapped to Switch Binary Command Class as Follow: 
1)

 

Basic Set = 255 maps to Binary Switch Set = 255 

2)

 

Basic Set = 0 maps to Binary Switch Set = 0   

3)

 

Basic Set = 1 ~ 99 maps to Binary Switch Set = 255 

4)

 

Basic Get/Report maps to Binary Switch Get/Report 

SmartStart 

SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code 
present  on  the  product  with  a  controller  providing  SmartStart  inclusion.  No  further  action  is 
required  and  the  SmartStart  product  will  be  added  automatically  within  10  minutes  of  being 
switched on in the network vicinity. 
 
This device supports SmartStart function. QR code is printed on the label that pasted on on surface 
of product and the outside of packing box. And the full DSK code is printed can be found on the 
packing box. 
 
The device will enter SmartStart if the device is not included in network after power up. And then 
2

nd

 SmartStart time delay approximately 16s 

3

rd

 SmartStart time delay approximately 32s 

4

th

 SmartStart time delay approximately 64s 

5

th

 SmartStart time delay approximately 128s 

6

th

 SmartStart time delay approximately 256s 

7

th

 SmartStart time delay approximately 512s 

 

Summary of Contents for 1Led

Page 1: ...tPlug 1Led User Manual Z Wave 700s S2 Version Version Written By Date Change List 1 0 Yongqi 20201022 Initial 1 1 Yongqi 20210116 Fixed Some Error Descriptions 1 2 Yongqi 20210304 Add Note for OTA Led...

Page 2: ...f Blue led will blink with 1s interval until inclusion successful Remove 1 Power up the device 2 Set Z Wave Controller into exclusion mode 3 Press and hold the button for 5s until Blue led lights is o...

Page 3: ...CLASS_INDICATOR COMMAND_CLASS_DEVICE_RESET_LOCALLY SWITCH_BINARY_REPORT NOTIFICATION_REPORT METER_REPORT INDICATOR_REPORT DEVICE_RESET_LOCALLY_NOTIFICATION 2 Control COMMAND_CLASS_BASIC BASIC_SET Devi...

Page 4: ...ive energy value 2 Execute the factory reset operation to reset the cumulative energy value The cumulative energy will not be reset if SmartPlug remove from Z Wave Network by exclusion operation Over...

Page 5: ...ize Byte Available Settings Default value 1 1 0 1 1 2 Button Switch Function Disable Setting this configuration as 0 will be disabling to turn on and off the relay by pressed button Parameter Number S...

Page 6: ...nt setting This configuration sets the maximum output current that the device can provide When the current consumed by the load is greater than the setting value the device will automatically cut off...

Page 7: ...itch Set 0 3 Basic Set 1 99 maps to Binary Switch Set 255 4 Basic Get Report maps to Binary Switch Get Report SmartStart SmartStart enabled products can be added into a Z Wave network by scanning the...

Page 8: ...Support Yes No SECURITY_KEY_S0 Yes SECURITY_KEY_S2_UNAUTHENTICATED Yes SECURITY_KEY_S2_AUTHENTICATED Yes SECURITY_KEY_S2_ACCESS No All Supports Command Class in Each NIF Lists Command Class Version N...

Page 9: ...with S0 level COMMAND_CLASS_MANUFACTURER_SPECIFIC is supported non securely And when device is included with S2 level COMMAND_CLASS_MANUFACTURER_SPECIFIC is supported securely only Notice 2 Indicates...

Page 10: ...Z Wave Network Send NIF Blink with 1s Interval Add to Z Wave Network Blink with 300ms Interval OTA is Running Note 1 The LED State is Not Changed when Led Is Busy On or Blink Such as Relay on Over Cu...

Reviews: