Parameter Number Size (Byte)
Available Settings
Default value
10
2
0 ~ 1000
50
11)
Interval of meter reporting setting
This configuration sets the interval of reporting electric quantity detection result. This
parameter is only valid when Parameter 6 is set as ‘1’. Unit: Second.
Parameter Number Size (Byte)
Available Settings
Default value
11
2
0 ~ 30000
300
●
To Simulate Over Current Protection Function, First User Must Turn on SmartPlug And Then
Write 1 Byte Data 0xFF(255) to
Parameter Number 99
. SmartPlug will Be Turned Off And Report
Alarm Messages to Hubs. Meantime Blue Led Will Blink with 1s Interval. This must set
“
Configuration No. 5
” to ‘1’.
Command Class Basic
The Basic Command Class is mapped to Switch Binary Command Class as Follow:
1)
Basic Set = 255 maps to Binary Switch Set = 255
2)
Basic Set = 0 maps to Binary Switch Set = 0
3)
Basic Set = 1 ~ 99 maps to Binary Switch Set = 255
4)
Basic Get/Report maps to Binary Switch Get/Report
SmartStart
SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code
present on the product with a controller providing SmartStart inclusion. No further action is
required and the SmartStart product will be added automatically within 10 minutes of being
switched on in the network vicinity.
This device supports SmartStart function. QR code is printed on the label that pasted on on surface
of product and the outside of packing box. And the full DSK code is printed can be found on the
packing box.
The device will enter SmartStart if the device is not included in network after power up. And then
2
nd
SmartStart time delay approximately 16s
3
rd
SmartStart time delay approximately 32s
4
th
SmartStart time delay approximately 64s
5
th
SmartStart time delay approximately 128s
6
th
SmartStart time delay approximately 256s
7
th
SmartStart time delay approximately 512s