Note:
If this configuration is set to ‘0’, all the functions of “Configuration No. 6, 8, 9, 10, 11” are
invalid. And No Current, Voltage, Active Power and Accumulated Power monitored and reported
any more.
Parameter Number Size (Byte)
Available Settings
Default value
5
1
0, 1
1
6)
Meter Report Enable
This configuration sets the meter report function enabled or disabled.
‘0’ – Disable meter report function.
‘1’ – Enable meter report function with time interval defined by “
Configuration No. 11
”.
When device is detected an OCP event or the relay turned on or turned off, device still will
report all meter values once if this value be set to ‘0’.
Parameter Number Size (Byte)
Available Settings
Default value
6
1
0, 1
1
7)
Countdown Time Setting
This configuration sets the time length for turning off the device. This configuration is only
valid when “
Configuration No.4
” is set to ‘1’. Unit: minute.
Parameter Number Size (Byte)
Available Settings
Default value (min)
5
2
0 ~ 30000
120
8)
Maximum output current setting
This configuration sets the maximum output current that the device can provide. When the
current consumed by the load is greater than the setting value, the device will automatically
cut off the power of the load and send out alarm information, and the led will light on 1.5s
with 2s interval. Unit: 0.01A (Ampere).
This value must be great than the alarm value defined by
Configuration No. 9
.
Parameter Number
Size (Byte)
Available Settings
Default value
8
2
0 ~ 1600
1600
9)
Output Current Alarm
This configuration sets the alarm value of the load current (volatility). When the load current
is large than this value, the led will light on 0.5s with 2s interval. Unit: 0.01A (Ampere).
This value must be less than the max. output value defined by
Configuration No. 8
.
Parameter Number Size (Byte)
Available Settings
Default value
9
2
0 ~ 1550
1500
10)
Current Change Ratio
This configuration sets the changed value of the load current (volatility). When the
differential between two measurements of current consumed by the load exceeds the value
set by this configuration, the device will report the last measured results automatically to
the controller.
The changed value = [Value]
×
0.01A.