Longo programmable controller LPC-2.DO4

STANDARDS   AND   PROVISIONS:   Standards,   recommendations,
regulations and  provisions of  the country in which the devices will
operate, must be considered while planning and setting up electrical
devices. Work on  100 .. 240 V AC  network is allowed for authorized
personnel only.

DANGER   WARNINGS:   Devices   or   modules   must   be   protected   from
moisture, dirt and damage during transport, storing and operation.

WARRANTY   CONDITIONS:   For   all   modules   LONGO   LPC-2   –   if   no
modifications   are   performed   upon   and   are   correctly   connected   by
authorized   personnel   –   in   consideration   of   maximum   allowed
connecting power, warranty of 24 months is valid from the date of
sale to the end buyer, but not more than 36 months after delivery
from Smarteh. In case of claims within warranty time, which are based
on material malfunctions the producer offers free replacement. The
method of return of malfunctioned module, together with description,
can be arranged with our authorized representative. Warranty does
not   include   damage   due   to   transport   or   because   of   unconsidered
corresponding   regulations   of   the   country,   where   the   module   is
installed.
This device must be connected properly by the provided connection
scheme in this manual. Misconnections may result in device damage,
fire or personal injury.
Hazardous  voltage   in  the  device  can  cause  electric  shock  and  may
result in personal injury or death.
NEVER SERVICE THIS PRODUCT YOURSELF!
This device must not be installed in the systems critical for life (e.g.
medical devices, aircrafts, etc.).

If the device is used in a manner not specified by the manufacturer,
the degree of protection provided by the equipment may be impaired.

Waste electrical and electronic equipment (WEEE) must be collected
separately!

LONGO LPC-2 complies to the following standards:

EMC: EN 61000-6-3:2007 + A1:2011, EN 61000-6-1:2007, EN 61000-
3-2:2006 + A1:2009 + A2: 2009, EN 61000-3-3:2013

LVD: IEC 61010-1:2010 (3

rd

 Ed.), IEC 61010-2-201:2013 (1

st

 Ed.)

Smarteh   d.o.o.   operates   a   policy   of   continuous   development.
Therefore we reserve the right to make changes and improvements to
any of the products described in this manual without any prior notice.

MANUFACTURER:
SMARTEH d.o.o.
Poljubinj 114
5220 Tolmin
Slovenia

ii

Summary of Contents for LPC-2.DD2

Page 1: ...USER MANUAL Longo programmable controller LPC 2 DO4 Triac Output module Version 6 SMARTEH d o o Poljubinj 114 5220 Tolmin Slovenia Tel 386 0 388 44 00 e mail info smarteh si www smarteh si...

Page 2: ...Longo programmable controller LPC 2 DO4 Written by SMARTEH d o o Copyright 2005 SMARTEH d o o User Manual Document Version 6 June 2019 i...

Page 3: ...ot include damage due to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection s...

Page 4: ...r LPC 2 DO4 Longo programmable controller LPC 2 DO4 1 DESCRIPTION 1 2 FEATURES 2 3 INSTALLATION 3 3 1 Connection scheme 3 3 2 Mounting instructions 5 3 3 Module labeling 7 4 TECHNICAL SPECIFICATIONS 8...

Page 5: ...ut module It can be used in a wide range of operation LED indicates triac output contacts state If it is on the module s connection pins are shorted refer to the Table 5 Module is powered from interna...

Page 6: ...DO4 2 FEATURES Figure 1 LPC 2 DO4 module Table 1 Technical data Snubberless zero crossing triac output also suitable for use with inductive loads Long life AC digital output Small dimensions and stan...

Page 7: ...tput 24 230 V AC Make contact triac output NO Table 3 K1 Internal BUS Data DC power supply Connection to I O module Table 4 K2 Internal BUS Data DC power supply Connection to I O module 1 Wires connec...

Page 8: ...tal output state On triac on conductive Off triac off non conductive NOTE Special care must be taken in case of high inductance loads e g Relays or contactors High inductance load may cause output fai...

Page 9: ...MMENDATION ON SWITCH OR CIRCUIT BREAKER PROTECTION There should be two poles main switch in the installation in order to switch off the unit The switch should meet the requirements of standard IEC6094...

Page 10: ...scheme in Figure 2 5 Switch ON main power supply Dismount in reverse order For mounting dismounting modules to from DIN rail a free space of at least one module must be left on the DIN rail NOTE LPC 2...

Page 11: ...e code 04 year of code opening 001 derivation code 001 version code reserved for future HW and or SW firmware upgrades 3 D C 16 05 is the date code 16 week and 05 year of production Label 2 descriptio...

Page 12: ...triac make contacts NO Output current 0 05 1 8 A continuous load Connection type screw type connector for stranded wire 0 75 to 2 5 mm2 Dimensions L x W x H 90 x 18 x 60 mm Weight 50 g Ambient tempera...

Page 13: ...following table describes all the changes to the document Date V Description 14 6 2019 6 Additional note added 1 7 2012 5 CGP General update 11 5 2010 4 Updated warranty permanence 30 6 2005 3 The in...

Page 14: ...Longo programmable controller LPC 2 DO4 6 NOTES 10...

Reviews: