OSD MENU SETTING
E. AUTO SCAN SET
● 66 + preset (Maxpro: 86+Preset) button is working as AUTO SCAN after setting.
E-1. AUTO SCAN - START ANGLE
To set the start position, press FOCUS FAR button then move the dome to the
required start position. Press FOCUS FAR button again is to escape.
E-2. AUTO SCAN - END ANGLE
To set the end position, press FOCUS FAR button then move the dome to the
required end position. Press FOCUS FAR button again is to escape.
E-3. AUTO SCAN - DIRECTION
Auto Scan directions are available as CW or CCW.
* CW: Clock wise direction (Default)
* CCW: Count Clock Wise Direction.
E-4. AUTO SCAN - ENDLESS
Auto Scan can be set to endless rotation by enabling the endless option.
The default setting is OFF.
E-5. AUTO SCAN - SPEED
The scan speed can be programmed from 05º/S up to 35 º/S.
The default setting is 10º/S.
E-6. AUTO SCAN - DWELL TIME
The dwell time at the start and end points can be programmed from 1 second to
30 seconds. The default setting is 03 seconds.
E-7. AUTO SCAN - SAVE AND EXIT
To save the memorized data and escape this page, move the joystick right or press
the pan right key when the cursor is at SAVE AND EXIT.
E-8. AUTO SCAN - EXIT
To escape this page, move joystick to the right direction.
AUTO SCAN SET
START ANGLE : XXX.X.XX.X
END ANGLE : XXX.X.XX.X
DIRECTION : CW
ENDLES
: OFF
SPEED
: 10
º
/S
DWELL TIME : 03
SAVE AND EXIT
EXIT
DEFAULT SETTING
Summary of Contents for STC-3902
Page 42: ...DIMENSIONS UNITS mm...