12
SET MASTER PASSWORD
The Set Master Password command changes the unit’s Master Password. Changing the Master
Password prevents unauthorized access to command mode. If you forget or lose your Master
Password you will be unable to seize control of your unit, either remotely or locally, until the
unit is refreshed. To refresh the MovieTImeS machine you must disconnect the power pack
plug. Hold the MODE button (on the front panel) while re-applying power. Continue to hold
the MODE button for 5 seconds after applying power to the unit.
If the Set Master Password command is entered correctly the user hears the success beep and
returns to command mode ready to enter the next command. If the entered password is not valid
the unit hangs up.
Syntax... (X X X X = any value 0000 - 9999)
* 9 2 # X X X X # Set Master Password
MEMORY REQUEST
The Memory Request command allows the user to identify how much memory is installed in the
system. If the command is correctly entered the user hears several beeps where each beep
represents 1 installed memory chip, or 8 MB of memory. After the command has completed the
unit returns to command mode ready to enter the next command.
Syntax...
* 8 0 # Memory Request
MEMORY TEST
The Memory Test command performs a diagnostic on the audio memory testing for errors. The
Memory Test command erases all messages and resets the unit to the factory default settings. If
the command is correctly entered the user hears the system busy signal for a period of time
while the test is performed, followed by the success beep or error tone depending on the
outcome of the test. After the command has completed the unit returns to command mode
ready to enter the next command.
Syntax...
* 8 1 # Memory Test
RESTORE DEFAULT CONFIGURATION
The Restore Default Configuration command restores the unit to the factory defaults. This
command erases all messages and brings the system to a fresh state which provides a good
starting point for system configuration. If the command is correctly entered the user hears the
system busy signal for a period of time while the units memory is erased, followed by the
success beep, returning to command mode ready to enter the next command. See appendix C
for a full listing of the default values. All messages are gone, and require re-recording.
Syntax:
* 9 9 # Restore default configuration