Functional Description
MVME2502 Installation and Use (6806800R96L)
93
4.20 Debugging Support
The following information shows the details of Penguin Edge debugging support as applied
to the MVME2502.
4.20.1 POST Code Indicator
The following table shows the LED status of the POST Codes. For the location of the POST
Code LEDs, see
Logic 1 means LED is ON, Logic 2 means LED is OFF.
4.20.2 JTAG Chain and Board
The MVME2502 is designed to work with separate JTAG board rather than with an on-
board JTAG multiplexer. The chip supports up to a 6-scan port and the board’s boundary
scan requires the following to function: ASSET hardware, JTAG board, and JTAG cable.
The MVME2502 provides a 60-pin header that connects to the JTAG board via customize
cable.
The JTAG bypass will connect when no XMC or PMC is connected to its corresponding
locations. Once an external XMC or PMC is unmounted its corresponding JTAG bypass will
close, to complete the JTAG chain.
Table 4-8
POST Code Indicator on the LED
Sequence D33
D34
D35
Description
1
Off
Off
Off
U-boot has been copied from SPI flash to CPU cache.
2
Off
On
Off
Serial console has been initialized, some text is visible on
the terminal.
3
Off
On
On
DDR has been initialized using SPD parameters, Execution
is still in the cache.
4
On
Off
Off
Execution has been relocated to RAM.
5
On
Off
On
PCI has been initialized.
6
On
On
Off
POST routines are finished.
7
On
On
On
Additional SW routines are finished.
8
Off
Off
Off
U-boot prompt is visible on the terminal, can start loading
OS image from USB, Ethernet, SATA SSD, SD.
Summary of Contents for MVME2502
Page 1: ...Penguin Edge MVME2502 Installation and Use P N 6806800R96L July 2022 ...
Page 8: ...8 MVME2502 Installation and Use 6806800R96L Table of Contents ...
Page 10: ...List of Figures 10 MVME2502 Installation and Use 6806800R96L ...
Page 18: ...18 MVME2502 Installation and Use 6806800R96L About this Manual About this Manual ...
Page 32: ...32 MVME2502 Installation and Use 6806800R96L Introduction Introduction ...
Page 96: ...96 MVME2502 Installation and Use 6806800R96L Functional Description Functional Description ...
Page 128: ...128 MVME2502 Installation and Use 6806800R96L Boot System Boot System ...
Page 140: ...140 MVME2502 Installation and Use 6806800R96L Programming Model Programming Model ...
Page 144: ...144 MVME2502 Installation and Use 6806800R96L Replacing the Battery Replacing the Battery ...
Page 148: ...148 MVME2502 Installation and Use 6806800R96L Related Documentation Related Documentation ...
Page 149: ...1 ...