Note that this switch is wired in parallel with the geographical address pins on the five row
connector. These switches must be in the OFF position when installed in a five row chassis
in order to get the correct address from the P1 connector. This switch also includes the
SCON control switches.
Figure 3-6 Geographical Address Switch
Table 3-18 Geographical Address Switch
Position
Function
Default
S1-1
VME SCON Auto
1
Auto-SCON
S1-2
VME SCON SEL
2
Non-SCON
S1-3
GAP
1
S1-4
GA4
1
S1-5
GA3
1
S1-6
GA2
1
S1-7
GA1
1
S1-8
GA0
1
1. The VME SCON MAN switch is OFF to select Auto-SCON mode. The switch is ON to select manual SCON mode which works
in conjunction with the VME SCON SEL switch.
2. The VME SCON SEL switch is OFF to select non-SCON mode. The switch is ON to select always SCON mode. This switch is
only effective when the VME SCON MAN switch is "ON".
Summary of Contents for MVME2502
Page 1: ...Penguin Edge MVME2502 Installation and Use P N 6806800R96L July 2022 ...
Page 8: ...8 MVME2502 Installation and Use 6806800R96L Table of Contents ...
Page 10: ...List of Figures 10 MVME2502 Installation and Use 6806800R96L ...
Page 18: ...18 MVME2502 Installation and Use 6806800R96L About this Manual About this Manual ...
Page 32: ...32 MVME2502 Installation and Use 6806800R96L Introduction Introduction ...
Page 96: ...96 MVME2502 Installation and Use 6806800R96L Functional Description Functional Description ...
Page 128: ...128 MVME2502 Installation and Use 6806800R96L Boot System Boot System ...
Page 140: ...140 MVME2502 Installation and Use 6806800R96L Programming Model Programming Model ...
Page 144: ...144 MVME2502 Installation and Use 6806800R96L Replacing the Battery Replacing the Battery ...
Page 148: ...148 MVME2502 Installation and Use 6806800R96L Related Documentation Related Documentation ...
Page 149: ...1 ...