42
Centellis 2x00 User Card-10GE Installation and Use (6806800H33E)
Board Exchange
Board Exchange
NOTICE
Board Damage
High humidity and condensation on the board surface causes short circuits.
Do not operate the board outside the specified environmental limits. Make sure the
board is completely dry and there is no moisture on any surface before applying
power.
Table 4-1
Environmental Requirements
Feature
Operating
Non-Operating (packed state)
Temperature
+5ºC (+41°F) to +40ºC (+104°F)
(normal operation) according to NEBS
Standard GR-63-CORE
-5°C (+23°F) to + 55°C (+131°F)
(exceptional operation) according to
NEBS Standard GR-63-CORE
-40ºC (-40°F) to +85ºC (+185°F)
Temp. change
+/- 0.25ºC/min according to NEBS
Standard GR-63-CORE
+/- 0.25ºC/min
Relative humidity
5% to 90% non-condensing according
to SMART EC internal environmental
requirements
5% to 95% non-condensing according
to SMART EC internal environmental
requirements
Vibration (tested
in target platform)
0.1g from 5 to 100Hz and back to 5Hz
at a rate of 0.1 octave/minute.
5-20Hz at 0.01g
2
/Hz
20-200Hz at -3.0dB/octave
Random 5-20Hz at 1m
2
/Sec
3
Random 20-200Hz at -3dB/octave
Shock
Half-sine, 11mSec, 30m/Sec
2
Blade level packaging
Half-sine, 6mSec at 180m/Sec
2
Free fall
-
200mm/all edges and corners
1.0 m (packaged) per ETSI 300 019-2-2
(Blade level packaging)
100mm (unpackaged) per GR-63-
CORE
Summary of Contents for Centellis 2x00 User Card-10GE
Page 1: ...Centellis 2x00 User Card 10GE Installation and Use P N 6806800H33E January 2020 ...
Page 6: ...List of Figures 6 Centellis 2x00 User Card 10GE Installation and Use 6806800H33E ...
Page 8: ...List of Tables 8 Centellis 2x00 User Card 10GE Installation and Use 6806800H33E ...
Page 18: ...18 Centellis 2x00 User Card 10GE Installation and Use 6806800H33E Safety Notes Safety Notes ...
Page 48: ...48 Centellis 2x00 User Card 10GE Installation and Use 6806800H33E Related Documentation ...
Page 49: ...1 ...