REMOTE CONTROL INTERFACES
5.1
RS232 SERIAL CONTROL PORT INTERFACE
PIN
Function
PIN
FUNCTION
1
Not Used
6
Not Used
2
RS232 send data
7
Not Used
3
RS232 receive data
8
Not Used
4
Not Used
9
Not Used
5
Ground Earth
10
Not Used
5.2
TCP/IP CONTROL PORT INTERFACE
5.2.1
TCP/IP CONNECTION VIA SWITCH
Utilise a standard CatX twisted pair patch cable between the TCP/IP control port and a network switch.
Both ends of the patch cable should be terminated to EIA/TIA 568B standard:
EIA/TIA 568B Standard Linear Order
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
5.2.2
TCP/IP CONNECTION DIRECT VIA CROSS-CONNECT
Utilise a “cross
-
connect” CatX twisted pair patch cable between the TCP/IP control port and the Ethernet
LAN port on a computer.
One end of the patch cable should be terminated to EIA/TIA 568B standard:
EIA/TIA 568B Standard Linear Order
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
One end of the patch cable should be terminated to EIA/TIA 568A standard:
EIA/TIA 568A Standard Linear Order
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
White/Green
Green
White/Orange
Blue
White/Blue
Orange
White/Brown
Brown
Summary of Contents for 4K-8x8-L
Page 1: ......
Page 9: ...4K 8x8 L USER MANUAL V1 0 2018 Smart e UK Ltd www smart e co uk PAGE 9 4 APPLICATION DIAGRAM...
Page 43: ...4K 8x8 L USER MANUAL V1 0 2018 Smart e UK Ltd www smart e co uk PAGE 43...
Page 45: ...4K 8x8 L USER MANUAL V1 0 2018 Smart e UK Ltd www smart e co uk PAGE 45...
Page 46: ...4K 8x8 L USER MANUAL V1 0 2018 Smart e UK Ltd www smart e co uk PAGE 46...
Page 48: ...4K 8x8 L USER MANUAL V1 0 2018 Smart e UK Ltd www smart e co uk PAGE 48...