Zero Adjustment Limits
Calibrated span shall not be less than 0.0085 URL and shall not exceed 2 URL.
Low range value shall not be below LRL.
Upper range value shall not be greater than URL.
(LRL = -URL for all models, except absolute, where LRL
vacuum).
Temperature Limits
Ambient :
-40
to
85
°
C
(-40 to 185
°
F)
Process :
-40
to 100
°
C (-40
to 212
°
F)
(Silicone Oil).
0
to
85
°
C (32
to 185
°
F)
(Fluorolube Oil).
-40
to 150
°
C (-40
to 302
°
F)
for LD301L.
-25
to
85
°
C (-13
to 185
°
F)
(Viton O-Rings).
Storage :
40
to
00
°
C (-40
to 212
°
F)
Digital Display :
-10
to
60
°
C (14
to 140
°
F)
-40
to
85
°
C (-40
to 185
°
F)
without damage.
Failure Alarm
In case of sensor or circuit failure, the self-diagnostics drives the output to 3.6 or 21.0 mA,
according to the user's choice.
Turn-on Time
Performs within specifications in less than 5.0 seconds after power is applied to the transmitter.
Volumetric Displacement
Less than 0.15 cm
3
(0.01 in
3
).
Overpressure and Static Pressure Limits
From 3.45 kPa abs. (0.5 psia)* to:
8 MPa (1150 psi) for range 1.
16 MPa (2300 psi) for ranges 2, 3 & 4.
32 MPa (4600 psi) for models H & A5.
40 MPa (5800 psi) for model M5.
52 MPa (7500 psi) for model M6.
* except the LD301A model.
Flange Test Pressure: 60 MPa (8570 psi).
For ANSI/DIN Level flanges (LD301L models):
CLASS
RANGE
TEMPERATURE
150 lb
6 psia to 275 psi (-0,6 to 19 bar)
38ºC
300 lb
6 psia to 720 psi (-0,6 to 50 bar)
38ºC
PN10/16
-60 kPa to 1,4 Mpa
120ºC
PN25/40
-60 kPa to 4 MPa
120ºC
These overpressures will not damage the transmitter, but a new calibration may be necessary.
Humidity Limits
0 to 100% RH.
Damping Adjustment
Through the programmer: adjustable for any value greater than or equal to 0 seconds,
added to the sensor response time (0.2 seconds)
Configuration
Can be done through digital communication using the Hart Protocol or, partially, through local
adjustment.
0.9915
NEW
Summary of Contents for ld301
Page 14: ...LD301 Operation and Maintenance Instruction Manual 1 8...
Page 18: ...LD301 manual de Instru es Opera o e manuten o 2 4 Fig 2 3 LD301 Software Block Diagram...
Page 50: ...LD301 Operation and Maintenance Instruction Manual 4 16...
Page 55: ...Maintenance Procedure 5 5 Fig 5 1 Exploded View...
Page 62: ...LD301 Operation and Maintenance Instruction Manual 5 12...
Page 70: ...APPENDIX A...