28
REGULATION OF THE THERMOSTAT MINIMUM
Perform this operation with the oven already inserted in the cabinet and with the electric and
gas connections already carried out, as from previous instructions
It is necessary to perform the adjustment of the minimum every
time the type of gas is changed, in order to guarantee the good
functioning of the burners
In minimum position, the flame must be stable and must not
go off when passing from maximum to minimum, and vice-
versa. The height of the flame in minimum position must be of
about 5 mm.
Calibration of the minimum
Ignite the burner to be calibrated and make it function for a few minutes. Bring the knob
index to minimum position, remove the knob. Introduce a small Phillips screwdriver in the
opening on the left side of the thermostat shaft, optimise the
height of the flame by closing or opening the adjustment screw V
with the shaft locked. Carry out a few normal closing and opening
tests of the door and, in case of switch-off, slightly lift the
minimum.
NOTE: All adjustments must be realised only by qualified and authorised staff.
To guarantee a correct and safe operation, the oven must be suitably installed and connected
to earth/mass by qualified and authorised staff. Ask the installer to show you the position of
the connection ball valve to the gas mains and how to close it in case of need. Disconnect the
appliance from the electric mains before any intervention.