background image

Page 6 

 

Cleaning the Check Valve

If you’re experiencing little to no pressure or the pump is not priming and you’ve 

checked your filter screen and it’s clean, and you’ve gone through the other 

trouble shooting tips, you may need to clean the check valve. 

 

Remove the head of the pump, which is held on by 7 screws. 

 

The first piece inside the head of the pump is called a check valve, it’s the part responsible for building up 
pressure and pumping water/solution through the lines.  

 

Clean the check valve under hot, soapy water (such as a good grade dish soap).  

 

Give it a very light scrubbing with something like an old toothbrush, something with soft bristles. 

 

Then let it soak for about an hour or so in the hot soapy solution and replace in the pump and reassemble the 
pump. 

 

Most times this will restore most, if not all of the prime of a pump. 

If you’re still having issues with pressure after this step, it would be recommended to replace this part. 

Checking the Pressure Switch

If your motor is not running and you’ve checked the following: for loose wiring  

connections, fuse, the switch on the lead wire was “ON” and made sure you were connected 

to a fully charged battery and everything is fine, but the motor won’t run, then it’s time to check 

to see if the pressure switch is bad. 

 

Remove the cover off the 1” square box (pressure switch) on the head of the pump, the 
cover is 

 held on by one phillips-head screw. This will   expose the two red wires. 

 

With the pump connected to a good 12 volt power source and everything on. 

 

Slip the two red wires off the terminals and touch them together.  

 

If the motor runs, it means the pressure switch is bad and needs to be replaced.  

If it still doesn’t run, try bypassing the switch in the lead wire or using another lead wire. Even 

if a tester shows power to the pressure switch, it still could be the switch in the wire that is 

causing the problem. If still not responsive, use a voltmeter or electrical tester to make sure 

you are getting power to the head of the pump, as it could possibly be something in one of  

the wires or even the lead wire assembly may need to be replaced. 

 

Warning:

 It is NOT recommended to run the pump this way, as the pump will  

continue to run and not shut off.  

 

This could result in blown hoses when all discharges are closed. 

Also, this could result in premature failure of the pump completely. 

Try another 12-Volt battery

Quarter turn at a time clockwise until surging stops

Defective pressure switch

Troubleshooting

Bypass is not completely closed
System has leaks
Check for worn or dirty check valve
Excessive voltage
Improper adjustment of pressure switch
Damaged or defective wiring harness

Check for proper voltage

Check for worn or dirty check valve
Low flow may cause pump to surge
Spray wand is adjusted for a small or fine spray pattern
Slightly open bypass (if applicable) to overcome
If needed, pressure switch may need to be adjusted

Pump will not run:

Low Pressure/Low Flow:

Pump surges:

Pump continues to run:

Fuse blows:

Check for loose wiring
Make sure the ON/OFF switch is on
Check the fuse
Check for defective pressure switch
Check for a clogged strainer

Summary of Contents for 5301795

Page 1: ...NOT rotate within the grommets Alternate the tightening of the locknuts to provide even pressure on the grommet DO NOT OVER TIGHTEN the whiz locknuts as this may cause the boom tube to flatten slight...

Page 2: ...Item 3 against O ring Item 2 and slide both into the nozzle body opening firmly 4 Firmly tighten flynut Item 4 onto threads of nozzle body 5 Repeat for other side NOTE If water is shooting back on th...

Page 3: ...m nozzles Connect the lead wire to a fully charged 12 volt battery You may use either a stand alone battery or the battery on your towing vehicle Connect to the positive red terminal first then connec...

Page 4: ...valves if allowed to soak untreated for a length of time ALWAYS flush the pump as instructed after each use DO NOT allow chemicals to sit in the pump for extended times of idleness Follow the chemical...

Page 5: ...defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restr...

Page 6: ...d to a good 12 volt power source and everything on Slip the two red wires off the terminals and touch them together If the motor runs it means the pressure switch is bad and needs to be replaced If it...

Page 7: ...and before it shuts off reach down and shut the valve to the Closed position lever is perpendicular to the flow of fluid then shut off your pump Unscrew the knurled nut from the shut off valve leaving...

Page 8: ...loded View Parts List 800 UTL60BL 5301795 See DETAIL A DETAIL A Ref 1 1 Right Hand RH and Left Hand LH sides of the sprayer are determined as if you are standing behind the sprayer looking at it facin...

Page 9: ...Page 9 Exploded View Parts List Boomless Wet Boom Assembly 5275260 Center Nozzle Assembly 5275123 End Nozzle Assembly 5275122...

Page 10: ...btain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent o...

Reviews: