background image

Page 3 

 

Manifold Valves CLOSED 

IMPORTANT: 

Remove tank lid and be sure the tank is clean and free of 

any foreign material. Rinse tank out of any tank residue before filling with 

water to test.

 

Testing the Sprayer 

NOTE: 

It is VERY important for you to test your sprayer with plain water before actual 

spraying is attempted. This will enable you to check the sprayer for leaks without 

the possibility of losing any expensive chemicals. 

  

Fill the tank about 1/2 full with plain water and drive to the starting place for spraying.  

 

When you are ready to spray, turn the boom valve to the “on” position (Detail A). This will start 

solution spraying from the tips of the boom. The pressure will decrease slightly when the 

boom is spraying.  

Adjust the pressure by turning the “ON/OFF” valve lever on the bypass line valve (Detail B). 

Make sure your pattern is sufficient. You may down-pressure the system by ‘bypassing’ solu-

tion back into the tank. This is achieved by opening the bypass valve. Regulating pressure is 

done in this manner. 

 

Read the operating instructions and initially begin spraying by closing the ‘Pressure Adjust’ 

valve and opening the boom line valve (Detail A). This will enable the air in the line to be elimi-

nated (purged) through all the tips, while building pressure. When everything tests all right (no 

leaks and good pressure), add the desired chemicals to the mixture and water combination 

and start your spraying operation. Adjust the pressure and spray as you did in the testing 

procedure. 

Conditions of weather and terrain must be considered when setting the sprayer. Do not spray 

on windy days. Protective clothing must be worn in some cases. 

 

Be sure to read the chemical label(s) before application! 

 

Operation 

The pumping system draws solution from the tank, through the strainer and to the pump. The 

pump forces the solution under pressure to the handgun or boom nozzles. 

 

Connect the lead wire to a fully charged 12 volt battery. You may use either a stand-alone 

battery or the battery on your towing vehicle. Connect to the positive (red) terminal first, then 

connect to the negative (black) terminal. Then connect the end of the lead wire to the end of 

the pump. When disconnecting, disconnect the end of the pump wire from the lead wire, then 

disconnect the negative (black) connection and finally the positive (red) connection. The lead 

wire has an On/Off switch to activate the pump. “-” is on and “O” is off. 

 

Fill the tank part way with water and then add the desired amount of chemical to be sprayed. Finish filling tank to proper level. Turn the pump on and 

by depressing the “-” side of the rocker switch. The pump is equipped with a pressure switch that is pre-set at the factory to shut the pump off when all 

discharges are closed. 

 

The pump will turn back on when one of the following actions occurs: 

 

Handgun lever is squeezed to spray the handgun. 

 

Boom valve is opened to broadcast spray with the boom. 

 

Bypass valve is opened to re-circulate solution back into the tank. 

 

When spraying with either the boom or the handgun, pressure may be reduced by slowly opening the bypass valve until desired pressure is achieved. 

Opening the valve decreases pressure, closing the valve increases pressure. When spraying with the boom, the proper method to set the pressure is 

to open the boom valve completely and if a lower pressure is desired, then slowly open the bypass valve until that pressure is obtained. 

 

For the safest and most efficient chemical application, you will need to calibrate your sprayer using the tip and speed charts. Once you have deter-

mined the proper speed and pressure settings, you will need to consult your chemical label for the amount of chemical to be added to the tank. Read 

the entire label. Use only according to label directions. 

 

Detail A 

Detail B 

***IMPORTANT REMINDER*** 

This sprayer comes with an On/Off valve located on your intake 

line. You must make sure the valve is in the “open” position before 

using your sprayer. 

Summary of Contents for 5301795

Page 1: ...NOT rotate within the grommets Alternate the tightening of the locknuts to provide even pressure on the grommet DO NOT OVER TIGHTEN the whiz locknuts as this may cause the boom tube to flatten slight...

Page 2: ...Item 3 against O ring Item 2 and slide both into the nozzle body opening firmly 4 Firmly tighten flynut Item 4 onto threads of nozzle body 5 Repeat for other side NOTE If water is shooting back on th...

Page 3: ...m nozzles Connect the lead wire to a fully charged 12 volt battery You may use either a stand alone battery or the battery on your towing vehicle Connect to the positive red terminal first then connec...

Page 4: ...valves if allowed to soak untreated for a length of time ALWAYS flush the pump as instructed after each use DO NOT allow chemicals to sit in the pump for extended times of idleness Follow the chemical...

Page 5: ...defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restr...

Page 6: ...d to a good 12 volt power source and everything on Slip the two red wires off the terminals and touch them together If the motor runs it means the pressure switch is bad and needs to be replaced If it...

Page 7: ...and before it shuts off reach down and shut the valve to the Closed position lever is perpendicular to the flow of fluid then shut off your pump Unscrew the knurled nut from the shut off valve leaving...

Page 8: ...loded View Parts List 800 UTL60BL 5301795 See DETAIL A DETAIL A Ref 1 1 Right Hand RH and Left Hand LH sides of the sprayer are determined as if you are standing behind the sprayer looking at it facin...

Page 9: ...Page 9 Exploded View Parts List Boomless Wet Boom Assembly 5275260 Center Nozzle Assembly 5275123 End Nozzle Assembly 5275122...

Page 10: ...btain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent o...

Reviews: