DO

 

 

Clean and rinse your pump after each use with Fimco Tank 
Neutralizer 

 

Winterize your pump or sprayer by rinsing, draining and  
running RV Antifreeze through it before storing for the winter. 

 

Use clean water for your spray mixture 

 

Store inside a building when not in use. 

DON’T

 

 

Use to pump bleach. 

 

Use to pump petroleum products such as diesel fuel,    
gasoline or kerosene 

 

Leave your pump sit with spray mixture in it for extended 
periods 

 

Use dirty or unfiltered water for spraying 

Troubleshooting the Pump: 

Motor does not run: 

 

Check for loose wiring connection(s). 

 

Make sure the 'ON/OFF' switch in the lead wire assembly 

is in the 'ON' position. "I" is the 'ON' position and 'O' is 

the 'OFF' position. 

 

Check for defective pressure switch. Make sure you are 

connected to a good  12 volt power source. Make sure 

any on/off switches are in the 'on' position.  Remove the 

cap to the pressure switch. Pull both red wires off of their 
terminals, and touch the two ends together. If your pump 

runs when you do this, your   pressure switch will need to 

be replaced. 

 

Check the fuse. 

 

Check for low voltage at the power supply. 

 
Pump does not prime: 

 

Check for air leaks in supply line. 

 

Check for debris in the check valve assembly. 

 

Check for defective check valve. 

 

Check for clogged strainer/filter. 

 

Check for cracks in the pump housing. 

 

Check for empty product supply. 

 

Low Pressure/Low Flow: 

 

Check for leaks in the discharge line. 

 

Check for restriction in the discharge line. 

 

Check for debris in nozzle orifice. 

 

Check for clogged strainer. 

 

Check for proper voltage—try another 12-volt battery. 

 

Pulsating flow (surging): 

 

Low flow may cause pump to surge. 

 

Spray wand is adjusted for a small or fine spray     

pattern. 

 

Slightly open bypass (if applicable) to overcome. 

 

If needed, pressure switch may need to be adjusted—

adjust a quarter turn at a time clockwise until surging 
stops. 

 

Check for defective pressure switch. 

 

Check for leaks in the discharge line. 

 

Check for restriction in the discharge line. 

 

Check for debris in nozzle orifice. 

 

Discharge hose may be too long. 

 

Check for clogged strainer. 

 

Motor continues to run after discharge is shut off: 

 

Check for empty product supply. 

 

Check for open bypass valve. (if equipped) 

 

Check for low voltage. 

 

Check for leak in discharge line. 

 

Check for defective pressure switch. 

 

System has leaks. 

 

Fuse blows: 

 

Excessive voltage. 

 

Improper adjustment of pressure switch. 

 

Damaged or defective wiring harness. 

 

Half-moon & counterweight are sticking. 

 

Defective pressure switch. 

Replacement Pump:  5151088 

 

Includes:   

1/2” MNPT Port Kit Fitting #5168832 

1/2” Hose Barb Port Kit Fitting #5168833 

Pump Model:  5281372 

4.5 GPM, 60 PSI 

Available Replacement Parts 

Summary of Contents for 5301795

Page 1: ...NOT rotate within the grommets Alternate the tightening of the locknuts to provide even pressure on the grommet DO NOT OVER TIGHTEN the whiz locknuts as this may cause the boom tube to flatten slight...

Page 2: ...Item 3 against O ring Item 2 and slide both into the nozzle body opening firmly 4 Firmly tighten flynut Item 4 onto threads of nozzle body 5 Repeat for other side NOTE If water is shooting back on th...

Page 3: ...m nozzles Connect the lead wire to a fully charged 12 volt battery You may use either a stand alone battery or the battery on your towing vehicle Connect to the positive red terminal first then connec...

Page 4: ...valves if allowed to soak untreated for a length of time ALWAYS flush the pump as instructed after each use DO NOT allow chemicals to sit in the pump for extended times of idleness Follow the chemical...

Page 5: ...defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restr...

Page 6: ...d to a good 12 volt power source and everything on Slip the two red wires off the terminals and touch them together If the motor runs it means the pressure switch is bad and needs to be replaced If it...

Page 7: ...and before it shuts off reach down and shut the valve to the Closed position lever is perpendicular to the flow of fluid then shut off your pump Unscrew the knurled nut from the shut off valve leaving...

Page 8: ...loded View Parts List 800 UTL60BL 5301795 See DETAIL A DETAIL A Ref 1 1 Right Hand RH and Left Hand LH sides of the sprayer are determined as if you are standing behind the sprayer looking at it facin...

Page 9: ...Page 9 Exploded View Parts List Boomless Wet Boom Assembly 5275260 Center Nozzle Assembly 5275123 End Nozzle Assembly 5275122...

Page 10: ...btain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent o...

Reviews: