SMA America, LLC
4 Product Description
Installation Manual
SB3-5TLUS22-IA-en-10
23
4.4 Display
The display shows the current operating data of the inverter (e.g., current power, daily energy, total
energy) as well as events or error messages. The power and energy are displayed as bars in the
diagram.
Figure 8: Display layout (example)
Item
Designation
Explanation
A
Power
Current power
B
Day
Daily energy
C
Total
Displays the total amount of energy fed in up
until now
D
Active functions
Displays the activated or active functions for
communication, network system services or
temperature derating
E
Line conductor
Line conductor involved for the values displayed
F
Event number relating to the
power distribution grid
Event number of errors relating to the power
distribution grid
G
Output voltage/output current Displays output voltage and output current of a
line conductor in alternation
H
Event number relating to the
inverter
Event number of errors relating to the inverter
I
Input voltage/input current
Displays input voltage and input current of one
input in alternation
kVAr
kVArh
kWh
MVArh
MWh
kW
kW
h
A
B
C
D
E
F
G
H
K
L
M
I