background image

Repair Parts and Maintenance Guide

145

Faucets and

Soap Dispensers

The information contained in this document is subject to change without notice.

BASYS

®

  

Infrared Sensor Activated

Remove crown by loosening hex 

screw located on underside of spout 

and slide crown down and lift off.

NOTE: Screw is captive within 

faucet body and will NOT fall out.

UPGRADE FAUCET FUNCTIONALITY

LED DISPLAY DIAGNOSTIC CODES

Place new crown on faucet by sliding 

onto spout and tightening hex screw 

on underside of spout.

NOTE: All electronics are fully 

encapsulated in the crown 

and thus protected from the 

environment and easy to replace 

or upgrade.

RED

GREEN

RED

GREEN

RED

RED

RED

RED

RED

GREEN

GREEN

GREEN

RED

RED

RED

RED LED1

GREEN LED2

RED LED3

Function

LED1 LED2

LED3

Description 1

Description 2

Start Up Boot

LED1 and LED2 alternate blinking

Fast Toggle

Battery Check after Start Up

LED1 on for 2 sec, if battery greater than 3.5V

Line Power Check after Start Up

LED3 on for 2 sec, if line power greater than 3.5V

IR Adjust Process

LED1 blinking while IR adjusts

Few seconds

IR Adjust IR

LED2 on for 2 sec, if adjustment OK

Battery Low

LED1 blinks 3x, if battery is less than warning level

Only while in detection mode

Battery Empty

LED1 double flashes 3x, if battery is 

less than empty level

Only while in detection mode

Valve Error

LED3 double flashes 3x, if valve 

current error; flash after the 3rd error,

off after the 3rd good operation

Flashes after the 3rd error, off 

after the 3rd good operation

IR Activation

LED2 on for 2 sec, if IR-click has been activated

After 5 sec. automatically back to 

operating mode

Cleaning Mode

LED1 4-in-1 flash, if cleaning mode is activated

During “Cleaning Mode” is activated 

Permanent 4-in-1 flashes

COLOR LEDs BLINKING

COLOR LEDs ON

UNLOCK

LOCK

UNLOCK

LOCK

Summary of Contents for EFX-8 SERIES

Page 1: ...26045 MIX 135 A Thermostatic Below Deck Mixing Valve 10 3365461 ETF 617 A Bak Chek Tee Assembly 11 0335023 EAF 23 A Splitter 12 0335024 EAF 24 A 11 13 16 300 mm Extension Cable 0335025 EAF 25 A 47 1 4 1200 mm Extension Cable 0335015 EAF 17 A 126 3200 mm Extension Cable 13 0335009 EAF 11 Plug in Adapter US 0335041 EAF 41 Plug in Adapter EU 0335039 EAF 39 Plug in Adapter UK 0335037 EAF 37 Box Mount ...

Page 2: ... no changes are made 12 24 LINE PURGE FEATURE 1x 24 sec Activate 12HR Deactivate Activate 24HR 1x 24 sec 1x 2x 3x Steps to Default IR Function Activate Function Setting Clic IR Activation Cover IR clic approximately for 2 sec until LED will flash GREEN 1x then remove finger from IR clic Active for 5 sec Cleaning IR activation Cover IR clic 2x confirmation 2 min Mode of the function is active by a ...

Page 3: ...should blink to indicate programming mode SENSOR RANGE ADJUSTMENT BATTERY REPLACEMENT NOTE Replace battery when LED1 indicator flashes RED each time faucet is in use or when faucet stops functioning LED1 is identified by the battery symbol NOTE Turning off water is not necessary Remove crown by loosening 2 hex screws located on underside of spout and slide crown down and lift off NOTE Screw is cap...

Page 4: ...n with arrow locking the unit and opening water path Slide on crown and secure in 2 places NOTE Turning off water is not necessary due to integrated automatic stop valve Retrieve spray removal tool located near the spray insert Insert spray removal tool into spray slot by sliding hook end of key between faucet spout and insert Pull insert out of faucet once hooked Remove crown by loosening hex scr...

Page 5: ... Boot LED1 and LED2 alternate blinking Fast Toggle Battery Check after Start Up LED1 on for 2 sec if battery greater than 3 5V Line Power Check after Start Up LED3 on for 2 sec if line power greater than 3 5V IR Adjust Process LED1 blinking while IR adjusts Few seconds IR Adjust IR LED2 on for 2 sec if adjustment OK Battery Low LED1 blinks 3x if battery is less than warning level Only while in det...

Page 6: ...s only a slow flow or dribble when sensor is activated A Water supply stop s are partially closed Completely open water supply stop s 6 Faucet DOES NOT stop delivering water or continues to drip after user is no longer detected A Faucet is not working properly Clean sensor window if problem persists contact Sloan Technical Support see below 7 LED indicator blinks RED when faucet is in use A Batter...

Reviews: