Repair Parts and Maintenance Guide
145
Faucets and
Soap Dispensers
The information contained in this document is subject to change without notice.
BASYS
®
Infrared Sensor Activated
Remove crown by loosening hex
screw located on underside of spout
and slide crown down and lift off.
NOTE: Screw is captive within
faucet body and will NOT fall out.
UPGRADE FAUCET FUNCTIONALITY
LED DISPLAY DIAGNOSTIC CODES
Place new crown on faucet by sliding
onto spout and tightening hex screw
on underside of spout.
NOTE: All electronics are fully
encapsulated in the crown
and thus protected from the
environment and easy to replace
or upgrade.
RED
GREEN
RED
GREEN
RED
RED
RED
RED
RED
GREEN
GREEN
GREEN
RED
RED
RED
RED LED1
GREEN LED2
RED LED3
Function
LED1 LED2
LED3
Description 1
Description 2
Start Up Boot
LED1 and LED2 alternate blinking
Fast Toggle
Battery Check after Start Up
LED1 on for 2 sec, if battery greater than 3.5V
Line Power Check after Start Up
LED3 on for 2 sec, if line power greater than 3.5V
IR Adjust Process
LED1 blinking while IR adjusts
Few seconds
IR Adjust IR
LED2 on for 2 sec, if adjustment OK
Battery Low
LED1 blinks 3x, if battery is less than warning level
Only while in detection mode
Battery Empty
LED1 double flashes 3x, if battery is
less than empty level
Only while in detection mode
Valve Error
LED3 double flashes 3x, if valve
current error; flash after the 3rd error,
off after the 3rd good operation
Flashes after the 3rd error, off
after the 3rd good operation
IR Activation
LED2 on for 2 sec, if IR-click has been activated
After 5 sec. automatically back to
operating mode
Cleaning Mode
LED1 4-in-1 flash, if cleaning mode is activated
During “Cleaning Mode” is activated
Permanent 4-in-1 flashes
COLOR LEDs BLINKING
COLOR LEDs ON
UNLOCK
LOCK
UNLOCK