Repair Parts and Maintenance Guide
144
The information contained in this document is subject to change without notice.
Faucets and Soap Dispensers
BASYS
®
Infrared Sensor Activated
NOTE: Turning off water is not necessary, due to integrated automatic stop
valve.
Rotate solenoid assembly counter-
clockwise through a 45º angle.
Pull solenoid caddy from faucet.
NOTE: Strainer can be removed,
cleaned and replaced at this time.
Insert new solenoid caddy at a
45° angle.
Remove crown by loosening hex
screw located on underside of spout
and slide crown down and lift off.
NOTE: Screw is captive within
faucet body and will NOT fall out.
REPLACING THE SOLENOID STRAINER (FILTER)
UNLOCK
LOCK
UNLOCK
LOCK
UNLOCK
LOCK
UNLOCK
LOCK
Rotate solenoid caddy clockwise to
align with arrow, locking the unit
and opening water path.
Slide on crown and secure in
2 places.
NOTE: Turning off water is not necessary, due to integrated automatic stop
valve.
Retrieve spray removal tool located
near the spray insert.
Insert spray removal tool into spray
slot by sliding hook end of key
between faucet spout and insert.
Pull insert out of faucet once
hooked.
Remove crown by loosening hex
screw located on underside of spout
and slide crown down and lift off.
NOTE: Screw is captive within
faucet body and will NOT fall out.
REPLACE SPRAY INSERT
Install new insert.
NOTE: If changing to a different
flow rate solenoid caddy must be
changed in conjunction.
Return spray removal tool to storage
location.
NOTE: This can only be done once
spray head is installed. This will lock
the spray head in place.
NOTE: If spray head is inserted
incorrectly – key will not lock in
properly. Turn faucet on to push
insert out and re-install.
Slide on crown and secure.