background image

Repair Parts and Maintenance Guide

142

The information contained in this document is subject to change without notice.

Faucets and  Soap Dispensers

BASYS

®

  

Infrared Sensor Activated

As the user’s hands enter the beam’s effective range, the beam is reflected 

back into the sensor receiver and activates the solenoid valve allowing water 

to flow from the faucet. Water will flow until the hands are removed or until 

the faucet reaches its automatic time out limit setting.

OPERATION

This feature will operate the faucet 

every 12 or 24 hours since last 

use, if not used to prevent stagnant 

water conditions.
Default purge duration is two 

minutes.
Consult factory regarding other 

timing options.
IR activation (see above). Cover IR 

clic approximately 24 sec. (ignore 

LED indications during this period). 

Release when requested program 

is reached. (See diagram to right). 

Programming mode will time out 

after 2 minutes if no changes are 

made.

12/24 LINE PURGE FEATURE

Activate 12HR

Deactivate

Activate 24HR

1x 24 sec 

...1x

...2x

...3x

+

 ...

Activate 12HR

Deactivate

Activate 24HR

1x 24 sec 

...1x

...2x

...3x

+

 ...

  

Steps to  

Default  IR 

 Function 

Activate  Function 

Setting 

Clic

 

IR Activation

  Cover IR clic approximately for 2 sec.  

–– 

–– 

  

until LED will flash GREEN 1x - then remove  

  

finger from IR clic (Active for 5 sec.) 

 

Cleaning

 

IR activation; Cover IR clic 2x - confirmation  

2 min. 

–– 

 

Mode

 

of the function is active by a couple flashes  

  

by the LED; to return to normal operation cover  

  

IR clic 1x or the faucet will automatically return  

  

to normal function after 2 min.

 

12/24

 

Line

 

See below. 

Off 

Off 

 

Purge

  

  12HR 

 

Feature

  

  24HR

 

Sensor

 

See next page. 

1-8 

 

Range

 

 

Adjustment

 

Reset

 

IR activation; Cover IR clic 2x; LED will flash 5x 

Manually  –– 

 

Electronics

 

Cover IR clic 1x for 5 sec. until LED  

  

flashes 4x, then remove finger from IR clic 

  

Wait for 20 sec. 

  

(After 10 sec. water will flow for 6 sec.  

  

and automatically adjust to environment)

Security Off

 

After 90 seconds (max) of hand and/or object  

On 

–– 

  

within sensor appears permanent, waterflow  

  

will stop and will remeasure environment

Please contact factory for more extensive programming options.

Summary of Contents for EFX-8 SERIES

Page 1: ...26045 MIX 135 A Thermostatic Below Deck Mixing Valve 10 3365461 ETF 617 A Bak Chek Tee Assembly 11 0335023 EAF 23 A Splitter 12 0335024 EAF 24 A 11 13 16 300 mm Extension Cable 0335025 EAF 25 A 47 1 4 1200 mm Extension Cable 0335015 EAF 17 A 126 3200 mm Extension Cable 13 0335009 EAF 11 Plug in Adapter US 0335041 EAF 41 Plug in Adapter EU 0335039 EAF 39 Plug in Adapter UK 0335037 EAF 37 Box Mount ...

Page 2: ... no changes are made 12 24 LINE PURGE FEATURE 1x 24 sec Activate 12HR Deactivate Activate 24HR 1x 24 sec 1x 2x 3x Steps to Default IR Function Activate Function Setting Clic IR Activation Cover IR clic approximately for 2 sec until LED will flash GREEN 1x then remove finger from IR clic Active for 5 sec Cleaning IR activation Cover IR clic 2x confirmation 2 min Mode of the function is active by a ...

Page 3: ...should blink to indicate programming mode SENSOR RANGE ADJUSTMENT BATTERY REPLACEMENT NOTE Replace battery when LED1 indicator flashes RED each time faucet is in use or when faucet stops functioning LED1 is identified by the battery symbol NOTE Turning off water is not necessary Remove crown by loosening 2 hex screws located on underside of spout and slide crown down and lift off NOTE Screw is cap...

Page 4: ...n with arrow locking the unit and opening water path Slide on crown and secure in 2 places NOTE Turning off water is not necessary due to integrated automatic stop valve Retrieve spray removal tool located near the spray insert Insert spray removal tool into spray slot by sliding hook end of key between faucet spout and insert Pull insert out of faucet once hooked Remove crown by loosening hex scr...

Page 5: ... Boot LED1 and LED2 alternate blinking Fast Toggle Battery Check after Start Up LED1 on for 2 sec if battery greater than 3 5V Line Power Check after Start Up LED3 on for 2 sec if line power greater than 3 5V IR Adjust Process LED1 blinking while IR adjusts Few seconds IR Adjust IR LED2 on for 2 sec if adjustment OK Battery Low LED1 blinks 3x if battery is less than warning level Only while in det...

Page 6: ...s only a slow flow or dribble when sensor is activated A Water supply stop s are partially closed Completely open water supply stop s 6 Faucet DOES NOT stop delivering water or continues to drip after user is no longer detected A Faucet is not working properly Clean sensor window if problem persists contact Sloan Technical Support see below 7 LED indicator blinks RED when faucet is in use A Batter...

Reviews: