background image

PARTS LIST

SLOAN VALVE COMPANY • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60133

Phone: 1-800-9-VALVE-9 (1-800-982-5839) • Fax: 1-800-447-8329 • www.sloanvalve.com

Copyright © 2011 SLOAN VALVE COMPANY

Code No.: 0816409 – Rev. 1 (07/11)

The information contained in this document is subject to change without notice.

Item

Part

No.

No.

Description

1

––

Spout Assembly

2

––

Integral Side Mixer Handle Cap

3

––

Integral Side Mixer Kit

4

EAF-2

Solenoid

5

––

Sensor Assembly

6

EAF-1

Mounting Hardware

7

EAF-44

Power Splitter

8

EAF-24-A

11-13/16” (300 mm) Extension Cable

EAF-25-A

47-1/4” (1200 mm) Extension Cable

EAF-17-A

126” (3200 mm) Extension Cable

9

EAF-1008

13” (330 mm) Flexible Supply Hose

10

EAF-9

Filter/Strainer

11

EAF-48

Battery Box

12

EAF-11-A

Plug-in Voltage Adapter, US Plug

2

1

4

3

5

6

7

9

8

10

11

12

Summary of Contents for EAF-700

Page 1: ...eries THERE ARE NO WARRANTIES WHICH ExTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEqUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER PRIOR TO INSTALLATION Prior to installing the Sloan Optima EAF 700 Series Faucets install the items listed below Also refer to rough in illustrations Lavatory sink Drain Line Hot Cold Water Supply Lines or Temper...

Page 2: ...HOT SUPPLY COLD SUPPLY 13 330 mm LONG FLEX HOSE 2 1 4 57 mm TEMPERED SUPPLY SPOUT O RING 1 3 16 30 mm MIN DIA HOLE REQUIRED 1 1 2 38 mm MAX DECK THICKNESS NUT RETAINER GASKET 13 330 mm LONG FLEX HOSE 5 11 3 151 m 5 14 SPOUT O RING MIXING LEVER CAN BE SET AND REMOVED 1 3 16 30 mm MIN DIA HOLE REQUIRED 1 1 2 38 mm MAX DECK THICKNESS NUT RETAINER GASKET HOT SUPPLY COLD SUPPLY 13 330 mm LONG FLEX HOSE...

Page 3: ...ly stop s D Flush supply stops before making connections Tighten the flex hose with strainer in place securely to the supply C A Install strainer and flex hose onto supply stop B ELECTRICAL CONNECTION FOR UP TO SIx 6 FAUCETS USING ONE ADAPTER 6 VDC PLUG IN ADAPTER LIMIT ONE FAUCET PER BATTERY PACK POWER SPLITTER ELECTRICAL CABLE POWER SPLITTER ELECTRICAL CABLE TO ADDITIONAL FAUCETS 6 MAx ...

Page 4: ...4 START UP Activate faucet by pressing the button one 1 time then immediately step away Faucet will run water for 4 seconds Wait 10 seconds and then the faucet is ready to use B Remove label from faucet sensor A 3 1x 7 3 1x 7 1x 7 A B C ...

Page 5: ...5 HOT LIMIT STOP ADJUSTMENT A B C D E LIMIT THE MAxIMUM WATER TEMPERATURE NOTE THIS DOES NOT TAKE THE PLACE OF AN ASSE 1070 CERTIFIED MIxING DEVICE BUT IS AN ADDED MEASURE TO LIMIT DELIVERY OF HOT WATER ...

Page 6: ...ADJUSTMENT FACTORY SETTING IS APPROPRIATE FOR THE MAJORITY OF APPLICATIONS AND SHOULD NOT REqUIRE RESETTING UNLESS UNDER ExTREME SITUATIONS 5 Sec 2x 1x5 Sec 1x 2x 8x 7x FACTORY DEFAULT 6 1 x 1x 2x 5x 4x A B C D E F G ...

Page 7: ...e faucet for cleaning for 2 minutes A Faucet will operate normally after 2 minutes or after pressing i q click button once B Faucet will operate normally after 2 minutes or after pressing i q click button once B Press again water flows and release when the desired time of water flow 0 5 seconds is reached B Sensor will flash once and then the faucet is ready to operate C I CONTINUOUS RUN II CLEANI...

Page 8: ...MENT No need to turn off water Loosen screw with hex wrench and remove cap Slide cover forward and lift off Remove battery Replace batteries with new CR P2 lithium battery Replace cover B C D Activate faucet by pressing i q cliq one 1 time then immediately step away E Faucet will operate for 4 seconds F Wait 10 seconds and then the faucet is ready for operation G A NOTE REPLACE BATTERY WHEN RED LE...

Page 9: ...strainer s if required C Spray head is clogged Remove clean and reinstall spray head Replace spray head if required D Faucet is not working properly Contact Sloan Valve Company Installation Engineering Department 5 Faucet does not stop delivering water or contrinues to drip after user is no longer detected A Faucet is not working properly Contact Sloan Valve Company Installation Engineering Depart...

Page 10: ...thout notice Item Part No No Description 1 Spout Assembly 2 Integral Side Mixer Handle Cap 3 Integral Side Mixer Kit 4 EAF 2 Solenoid 5 Sensor Assembly 6 EAF 1 Mounting Hardware 7 EAF 44 Power Splitter 8 EAF 24 A 11 13 16 300 mm Extension Cable EAF 25 A 47 1 4 1200 mm Extension Cable EAF 17 A 126 3200 mm Extension Cable 9 EAF 1008 13 330 mm Flexible Supply Hose 10 EAF 9 Filter Strainer 11 EAF 48 B...

Reviews: