8
BATTERY REPLACEMENT
NOTE: Replace Battery when LED1 indicator flashes red
each time faucet is in use or when faucet stops func-
tioning. LED1 is identified by the battery symbol.
NOTE: Turning off water is not necessary.
REPLACING THE SOLENOID/FILTER
A
Remove crown by loosening
hex screw located on
underside of spout and slide
crown down and lift off.
NOTE: Screw is captive
within faucet body.
B
Rotate solenoid assembly
counter-clockwise through a
45º angle.
C
Pull solenoid caddy from faucet.
NOTE: Strainer can be removed, cleaned and replaced at this time.
D
Insert new solenoid caddy at a
45° angle.
UNLOCK
NOTE: TURNING OFF WATER IS NOT NECESSARY, DUE TO INTEGRATED AUTOMATIC STOP VALVE.
UNLOCK
C
Slide on crown and secure in 2 places.
LOCK
A
Remove crown by loosening 2 hex screws
located on underside of spout and slide
crown down and lift off.
NOTE: Screw is captive within
faucet body and will NOT
fall out.
B
Remove red cover over the battery. Remove
battery holder from the faucet body. Replace
battery in the holder. Holder drops into the
faucet body. Place the red cover over the
battery.