5
NOTE: PLEASE CHECK AND INSTALL PER LOCAL PLUMBING CODES.
NOTE: SUPPLY LINES FROM SUPPLY STOPS TO FAUCET SUPPLIED BY
OTHERS.
Connect check tee or mixing valve to hot and cold water supplies.
IMPORTANT: FLUSH DIRT, DEBRIS, AND SEDIMENT FROM SUPPLY
LINE(S) BEFORE CONNECTING WATER SUPPLY. A PURGE TUBE
ASSEMBLY IS SUPPLIED FOR PURGE SUPPLY LINE (SEE BELOW).
2 - CONNECT TO WATER SUPPLY
SUPPLY LINE/
STOP
Open supply stop(s).
A
B
C
USE OF PURGE TOOL
A
C
D
E
B
After water supply is connected, open the supply stop(s). Rotate the
solenoid caddy counter-clockwise to a 45º angle to align with the
arrow. Remove solenoid caddy from the faucet.
Rotate the purge tube assembly counter-clockwise to a 45º angle
and remove from the faucet.
Insert the solenoid caddy at a 45º angle and rotate it clockwise to
align with the arrow. Locking the unit and opening the water path.
Route the solenoid cable under the battery pack and insert into the
holder (as shown). Note the polarity.
A purge tube assembly is provided to purge the supply line.
Insert the purge tube assembly at a 45º angle and rotate it clock-
wise to align with the arrow. Flush water to remove all dirt and
debris from the line.