background image

10

UPGRADE FAUCET FUNCTIONALITY

LED DISPLAY DIAGNOSTIC CODES

A

Remove crown by loosening hex screw located on underside of spout 
and slide crown down and lift off.

NOTE: Screw is captive within faucet body.

B

Place new crown on faucet by sliding onto spout and tightening hex screw 
on underside of spout.

NOTE: All electronics are fully encapsulated in the crown and thus 
protected from the environment and easy to replace or upgrade.

LOCK

UNLOCK

LED1

LED2

LED3

Function

LED1 LED2 LED3

Description 1

Description 2

Start Up Boot

LED1 and LED2 alternate blinking

Fast Toggle

Battery Check after Start Up

LED1 on for 2 sec, if battery greater than 3.5V

Line Power Check 

after Start Up

LED3 on for 2 sec, if line power  

is greater than 3.5V

IR Adjust Process

LED1 blinking while IR adjusts

Few seconds

IR Adjust OK

LED2 on for 2 sec, if adjustment OK

Battery Low

LED1 blinks 3x, if battery is less than warning 

level

Only while in  

detection mode

Battery Empty

LED1 double flashes 3x, if battery is less than 

empty level

Only while in  

detection mode

Valve Error

LED3 double flashes 3x, if valve current  

error; flash after the 3rd error, off after  

the 3rd good operation

Flashes after the 3rd error, 

off after the 3rd good  

operation

IR Activation

LED2 on for 2 sec, if IR-click has been activated

After 5 sec. automatically 

back to operating mode

Cleaning Mode

LED1 4-in-1 flash, if cleaning mode is activated

During “Cleaning Mode” is 

activated Permanent  

4-in-1 flashes

LEDs BLINKING

LEDs ON

Activate faucet by holding installation instructions  approximately 
1-1/2" (38 mm) in front of sensor window until Red LED turns on then re-
move instructions while faucet senses its surroundings. Wait for green LED 
on side of faucet.

C

Summary of Contents for BASYS EFX-8

Page 1: ...ons or organizations who purchase Sloan Valve Company s products directly from Sloan Valve Company for purpose of resale This warranty does not cover the life of the battery THERE ARE NO WARRANTIES WH...

Page 2: ...IN ACCORDANCE WITH APPLI CABLE CODES AND REGULATIONS FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS KEEP THREAD SEALANT OUT OF YOUR WATERWAY TO PREVENT COM PONENT PART DAMAGE DO NOT USE ANY SEALANT...

Page 3: ...mm 1 33 33 7 mm MOUNTING ASSEMBLY MOUNTING ASSEMBLY LESS MUD PLATE 4 55 115 5 mm 2 5 63 2 mm 0 12 3 mm 1 4 35 mm 0 8 20 mm 4 84 122 95 mm 4 55 115 5 mm 3 94 100 mm 1 97 50 mm KNOCK OUT FOR MAIN POWER...

Page 4: ...01 mm C Loop cable and install mud guard to protect wall while finishing D Finish wall and trim mud plate flush to wall E Rotate solenoid cable under battery pack and insert into holder as shown Note...

Page 5: ...en the supply stop s Rotate the solenoid caddy counter clockwise to a 45 angle to align with the arrow Remove solenoid caddy from the faucet Rotate the purge tube assembly counter clockwise to a 45 an...

Page 6: ...aterflow will stop and will remeasure environment On Please contact factory for more extensive programming options 3 START UP SEQUENCE ADAPTER BOX MOUNT TO FAUCET TO FAUCET B Remove label from sensor...

Page 7: ...TY OF APPLICATIONS AND SHOULD NOT REQUIRE RESETTING UNLESS UNDER EXTREME SITUA TIONS HIGH REFLECTION OR LOW LIGHT 2x 1x 5 sec 1x 2x 3x 4x 6x Factory Setting Longer Distance Shorter Distance 7x 8x 5x 1...

Page 8: ...ugh a 45 angle C Pull solenoid caddy from faucet NOTE Strainer can be removed cleaned and replaced at this time D Insert new solenoid caddy at a 45 angle UNLOCK NOTE TURNING OFF WATER IS NOT NECESSARY...

Page 9: ...sert NOTE If changing to a different flow rate solenoid caddy must also be changed E Return spray removal tool to storage location NOTE This can only be done once spray head is installed This will loc...

Page 10: ...D1 blinking while IR adjusts Few seconds IR Adjust OK LED2 on for 2 sec if adjustment OK Battery Low LED1 blinks 3x if battery is less than warning level Only while in detection mode Battery Empty LED...

Page 11: ...tteries low battery powered models Replace batteries refer to battery replacement on page 7 B Power failure hardwire models Check power supply 5 Faucet delivers only a slow flow or dribble when sensor...

Page 12: ...all Blue 4 EFX 19 Strainer Filter 5 EFX 1013 A Mounting Assembly 6A EFX 1009 A Bowed Crown Assembly 6B EFX 1010 A Solar Crown Assembly 6C EFX 1018 A Solar Crown with LCD Assembly 7 EFX 1015 A CR P2 Li...