Mounting, Installation and Commissioning
9173B_002-286e-07.10
Page
15
The following figure shows the items required for connect-
ing the quartz force link to a charge amplifier (such as the
Type 5015A).
Measuring chain for calibration purposes, consisting of
SlimLine force link, force distributing cap and flange,
cable and ICAM charge amplifier Type 5073A…
Fig. 7: Measuring chain for force calibration
Measuring chain for monitoring press force, consisting of:
SlimLine force link, cable, displacement sensor and
CoMo View
®
in desktop case
Fig. 8: Force-displacement measurement with process monitoring
Force signals from several SlimLine force links can be added to-
gether in terms of charge to form a sum signal. This is achieved
by routing the end of the cable with the BNC pos. connector
from each sensor to coupling Type 1743. The Type 1743 can
be plugged into the BNC neg. connection of the ControlMoni-
tor either directly or via an extension cable.
Cable e.g. Type 1631C2
Displacement sensor
Type 2101A3
Cable Type 1631C...
SlimLine force sensor
Type 9173B ... 9177B
maXYmo BL
Type 5867A…
F
z
Type
9173B to 9177B
F
z
Summary of Contents for 9173B
Page 1: ...Instruction Manual SlimLine Force Sensor Type 9173B to 9177B 9173B_002 286e 07 10...
Page 2: ...Instruction Manual SlimLine Force Sensor Type 9173B to 9177B 9173B_002 286e 07 10...
Page 27: ...Calibration and Maintenance 9173B_002 286e 07 10 Page 25 Fig 12 In situ calibration procedure...