![Sleipner SE-IP100 Installation Manual Download Page 4](http://html.mh-extra.com/html/sleipner/se-ip100/se-ip100_installation-manual_1292891004.webp)
4
2653
11
2021
-
SE IP 100 & SE IP 130
MC_0132
Thruster Measurements
Measurement
code
Measurement description
mm inch mm inch mm inch mm inch
ID
Internal tunnel diameter
185
7,28
185
7,28
250
9,84
250
9,84
H
Motor Height
499
19,65
510
20,08
511
20,12
511
20,12
W
Width
306
12,05
306
12,05
306
12,05
306
12,05
L
Length
381
15,00
381
15,00
381
15,00
381
15,00
WD
Water Depth
185
7,28
185
7,28
250
9,84
250
9,84
TL
Minimum tunnel length
158
6,22
158
6,22
253
9,96
253
9,96
TL (recommended)
Recommended tunnel length
195
7,68
216
8,50
303
11,93
303
11,93
T (min)
Minimum tunnel wall thickness
6
0,24
6
0,24
6
0,24
6
0,24
T (max)
Maximum tunnel wall thickness
8
0,31
8
0,31
8
0,31
8
0,31
* IP 100
12v
* IP 100
24v
* IP 130
12v
* IP 130
24v
*Valid for SE IP & SEP IP
MG_0076
H
W
L
TL
WD
ID
T
Tunnel centre line
Twin Propeller
Propeller position will
vary with each thruster
model
The gear leg/ propeller(s) must
never extend out of the tunnel