SLEIPNER MOTOR AS SE 140 S IP Installation And User Manual Download Page 22

 22

SE 50/140S ignition protected thruster assembly     

version 1.0.0 - 2017

Troubleshooting

Before seeking assistance at the help desk of your Side-Power dealer / distributor please perform these tests and make no-

tes of all measurements to ensure that they have as much information as possible to work on.

NB! All check points and solutions must be carried out after consulting the relevant information elsewhere in this manual to 

under-stand how the system is intended to work. If you are unable to understand what to check, you must consult a profes

-

sional.

Solution

Remove motor and replace the drive pin

Re-fasten or replace the propeller and/or key.

In case of a failure inside the gearhouse, we advice to get a replacement gear-hou-

se instead of attempting to repear the internal gear and bearing system.

If wrong, contact your dealer or distributor to obtain parts with the correct voltage.

The no load voltage should be:  

12V system =12,7V. If below 12,3V,your batteries are not in a good charge state 

or worn out and must be recharged or replaced before trying to run the thruster. 

If less than 8,5V at the thruster the voltage is to low for the thruster to operate 

correctly. In a 24V boat the thruster will operate down to approx. 12V, but the 

performance will be very bad. Find and correct the reason for this low voltage 

which will probably be one or more of these points: main battery cable sizes and 

connections, battery size and condition, fuse and main power switch performance.

If the thruster runs in both directions, try the same in the connector that goes into 

the back of the control panel. If it also works in this position, check the contact and 

wires on the back of the panel and try to engage this again by pushing both ON 

buttons simultaneously. If the panel does not turn on (see control light), measure 

the voltage between the Red and the Black in the contact going into the thruster. If 

the voltage is good, chances are that the panel is not working.

If it works by the thruster, and not by the panel there is a bad contact or a broken 

lead in the controlcables between these two test points.

Measure that you have the correct voltage between the Red (+) and all the other 

colours in the contact. If you do not get a reading.

 

If less than 10,5 V, the thruster will not perform at specified effect.

If one or more brushes are loose/has no tension from the brush-spring, the perfor-

mance will be low.

If there are growth in the tunnel, this will disturb / block the waterflow and especi

-

ally barnacles on the propeller will greatly reduce performance.

Re-charge battery(ies), if this is not sufficient, replace battery(ies).

Check for bad cable connections, if necessary tighten/re-adjust connections.

Check cable size in accordance to manual.

Shut off thruster main switch, tap slightly on the motor to see if it will release. Turn 

on thruster main switch. If solenoid is still in lock-in mode, contact your dealer.

Check

 

I

f the drive pin on the motor shaft is broken

Are the propellers in the tunnel fastened correctly on 

the prop-shaft (key present)

With the motor removed, turn the driveshaft from 

inside the boat to feel if the gears are engaging and 

turning the prop-shaft.

Check that the voltage of the electromotor are correct 

for your installation by their labels.

Check the voltage at the thruster between main minus 

input and main plus input point:

Check the voltage at the thruster while you are trying 

to run it. Keep main engine(s) running to have conti

-

nous charge to the batteries.

If the main solenoids on the thruster are not even try-

ing to engage (clicking) they are probably not getting 

a "run" signal from the control system. Try to run the 

thruster without the panel by directly connecting the 

red and the blue or the red and the grey wires in the 

controlcable contact coming from the thruster.  

Check voltage at thruster when running

Check that all the brush-springs sits correctly on the 

brushes in the electromotor.

Check that the propeller, gearhouse and tunnel is free 

from growth / barnacles etc.

Solenoid flapping, most probable cause: low voltage.

Solenoid lock-in, auto stop of thruster, auto retry every 

10 seconds.

» 

 The electromotor runs, but there is no thrust.

» 

 The thruster does not start at all or works only in one direction.

» 

 The thruster has an unexpected low performance.

» 

 The thruster runs for approximately 0,5 seconds every 4 seconds.

» 

 The thruster runs for approximately 0,5 seconds every 10 seconds.

Summary of Contents for SE 140 S IP

Page 1: ...017 SE 50 140 S IP Ignition Protected thruster assembly SLEIPNER MOTOR AS P O Box 519 N 1612 Fredrikstad Norway www side power com K e e p t h i s m a n u a l o n b o a r d SIDE POWER Thruster Systems...

Page 2: ...ller 12 Electromotor 13 Electrical installation 14 Control panel and control leads 15 Visual wiring diagram 16 Technical wiring diagram 17 Checklist for control of the installation 18 User s manual Im...

Page 3: ...time lapse device protects against sudden change of drive direction Electric thermal cut off switch in electromotor protects against over heating auto reset when electro motor cools down Flexible coup...

Page 4: ...hanges while the thruster is still running as it might cause damage to the thruster This manual is intended to support educated experienced staff and is therefore not sufficient in all details for the...

Page 5: ...en Die Oberkante des Tunnels mu mind einen halben Tunnel durchmesser unterhalb der Wasserlinie liegen Dieser Wert ist ein absolutes Minimum Besser ist ein Wert von ca des Tunneldurchmessers Optimal is...

Page 6: ...Kavitation trifft auf den Propeller und reduziert dessen Effektivit t und f hrt zu zus tzl Ger uschentwicklung 2 Abrundungen erm glichen da Wasser entlang der Rumpf au enseite angesaugt werden kann Da...

Page 7: ...sein Der m gliche Winkel der Aussparung h ngt meist von der Rumpfform ab Bedingt durch die Wasserstr mung in diesem Bereich sollte dieser Winkel leicht nach unten gerichtet sein 2 Der Geschwindigkeits...

Page 8: ...umpf umgeben ist Der Tunnel wird zur H lfte in den bestehenden Rumpf integriert die andere H lfte geht ber diesen hinaus Der Tunnel mu nur noch verst rkt und str mungsg nstig abgerundet werden Dies er...

Page 9: ...ss in an area of 12cm around the hole both inside and outside in the hull to cast the tunnel to the hull Fig 3 Insert the tunnel and mark its shape to fit the hull Fig 4 if you are installing with a d...

Page 10: ...nd in ausgeliefertem Zustand absolut wasserdicht Wird nicht eine spezielle Farbe gew nscht so sind keinerlei Gelcoat Topcoat oder Primer n tig die ansonsten zur Wasserdichtigkeit ben tigt werden Empfe...

Page 11: ...bracket is to be placed as this will cause possible failure of the gearhouse The motor bracket must fit steady on the tunnel if the tunnel is not smooth all bumps or uneven parts must be ground smooth...

Page 12: ...e the propeller shaft until the drive pin 4 aligns and moves into the slot groove in the propeller hub There should be almost no gap approximately 1mm between the propeller hub and the gear house Fig...

Page 13: ...5 Check the drive system by turning the propeller it will be a little hard to turn because of the gear reduction and the motor but you should easily be able to turn it by hand In some cases shallow in...

Page 14: ...e cable ends must be fitted with terminals and these must be well isolated against contact with anything but the proper connection point If the main switch and fuse are installed in the same gas area...

Page 15: ...proof based on the control panel lead ending outside of the area that requires ignition protection The control adapter lead must be fitted in the boat so there is no risk of damage to the insulation c...

Page 16: ...al wiring diagram 11 SP55S2i ignition protected thruster assembly 1 1 2006 Visual wiring diagram A2 A1 Fuse red grey blue black grey blue brown red 6 1232i Electronic control box Thermal switch Batter...

Page 17: ...for dual joystick panel Visual connection diagram for dual joystick panel We advice to use different battery banks for each thruster to ensure maximum performance when both are used at the same time...

Page 18: ...re clean dry and tight and the correct cable fuse and main switch sizes have been used The bolts holding the gearhouse and motorbracket together are tightened correctly Very important for IP protectio...

Page 19: ...ave come to a complete stop before performing a directions change of the thruster as it might cause damage to the thruster If the thruster stops giving thrust while the electromotor is running chances...

Page 20: ...port control the bow goes port etc In case of any doubts try in open waters first 5 Depending on the sideways speed of the bow you must disengage the control device shortly before the bow is in the de...

Page 21: ...propeller hub moves in Change the anode before every season or when about half the anode is gone Always use thread glue on the screw holding the anode to ensure it does not fall off Please observe tha...

Page 22: ...sure that you have the correct voltage between the Red and all the other colours in the contact If you do not get a reading If less than 10 5 V the thruster will not perform at specified effect If one...

Page 23: ...do so Prior to refund of the purchase price Purchaser must submit a statement in writing from a professional boating equipment supplier that the installation instructions of the Installation and Opera...

Page 24: ...n protected thruster assembly version 1 0 0 2017 SPARE PARTS In order to present the most up to date documentation we advise you to go to our website www side power com and locate your product to find...

Page 25: ...25 SE 50 140S ignition protected thruster assembly version 1 0 0 2017...

Page 26: ...26 SE 50 140S ignition protected thruster assembly version 1 0 0 2017...

Page 27: ...27 SE 50 140S ignition protected thruster assembly version 1 0 0 2017...

Page 28: ...e time it was published However Sleipner Motor AS can not accept liability for any inaccuracies or omissions it may contain Continuous product improvement may change the product specifications without...

Reviews: